Literature DB >> 21656548

Size-optimized 32-channel brain arrays for 3 T pediatric imaging.

Boris Keil1, Vijay Alagappan, Azma Mareyam, Jennifer A McNab, Kyoko Fujimoto, Veneta Tountcheva, Christina Triantafyllou, Daniel D Dilks, Nancy Kanwisher, Weili Lin, P Ellen Grant, Lawrence L Wald.   

Abstract

Size-optimized 32-channel receive array coils were developed for five age groups, neonates, 6 months old, 1 year old, 4 years old, and 7 years old, and evaluated for pediatric brain imaging. The array consisted of overlapping circular surface coils laid out on a close-fitting coil-former. The two-section coil former design was obtained from surface contours of aligned three-dimensional MRI scans of each age group. Signal-to-noise ratio and noise amplification for parallel imaging were evaluated and compared to two coils routinely used for pediatric brain imaging; a commercially available 32-channel adult head coil and a pediatric-sized birdcage coil. Phantom measurements using the neonate, 6-month-old, 1-year-old, 4-year-old, and 7-year-old coils showed signal-to-noise ratio increases at all locations within the brain over the comparison coils. Within the brain cortex the five dedicated pediatric arrays increased signal-to-noise ratio by up to 3.6-, 3.0-, 2.6-, 2.3-, and 1.7-fold, respectively, compared to the 32-channel adult coil, as well as improved G-factor maps for accelerated imaging. This study suggests that a size-tailored approach can provide significant sensitivity gains for accelerated and unaccelerated pediatric brain imaging.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21656548      PMCID: PMC3218247          DOI: 10.1002/mrm.22961

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Reduction of gradient acoustic noise in MRI using SENSE-EPI.

Authors:  Jacco A de Zwart; Peter van Gelderen; Peter Kellman; Jeff H Duyn
Journal:  Neuroimage       Date:  2002-08       Impact factor: 6.556

4.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

5.  Volume imaging with MR phased arrays.

Authors:  C E Hayes; N Hattes; P B Roemer
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

6.  Improved pediatric MR imaging with compressed sensing.

Authors:  Shreyas S Vasanawala; Marcus T Alley; Brian A Hargreaves; Richard A Barth; John M Pauly; Michael Lustig
Journal:  Radiology       Date:  2010-06-07       Impact factor: 11.105

7.  Head circumference from birth to eighteen years. Practical composite international and interracial graphs.

Authors:  G Nellhaus
Journal:  Pediatrics       Date:  1968-01       Impact factor: 7.124

8.  Design of matching networks for low noise preamplifiers.

Authors:  A Reykowski; S M Wright; J R Porter
Journal:  Magn Reson Med       Date:  1995-06       Impact factor: 4.668

9.  Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain.

Authors:  L L Wald; L Carvajal; S E Moyher; S J Nelson; P E Grant; A J Barkovich; D B Vigneron
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

10.  Head circumference reference data: birth to 18 years.

Authors:  A F Roche; D Mukherjee; S M Guo; W M Moore
Journal:  Pediatrics       Date:  1987-05       Impact factor: 7.124

View more
  48 in total

1.  Evaluation of a Flexible 12-Channel Screen-printed Pediatric MRI Coil.

Authors:  Simone Angela Winkler; Joseph Corea; Balthazar Lechêne; Kendall O'Brien; John Ross Bonanni; Akshay Chaudhari; Marcus Alley; Valentina Taviani; Thomas Grafendorfer; Fraser Robb; Greig Scott; John Pauly; Michael Lustig; Ana Claudia Arias; Shreyas Vasanawala
Journal:  Radiology       Date:  2019-02-26       Impact factor: 11.105

2.  Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics.

Authors:  Bastien Guérin; Matthias Gebhardt; Peter Serano; Elfar Adalsteinsson; Michael Hamm; Josef Pfeuffer; Juergen Nistler; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

3.  Signal-to-noise ratio and parallel imaging performance of commercially available phased array coils in 3.0 T brain magnetic resonance imaging.

Authors:  Tsukasa Yoshida; Kensei Shirata; Atsushi Urikura; Michitoshi Ito; Yoshihiro Nakaya
Journal:  Radiol Phys Technol       Date:  2015-05-26

Review 4.  MRI evaluation and safety in the developing brain.

Authors:  Shannon Tocchio; Beth Kline-Fath; Emanuel Kanal; Vincent J Schmithorst; Ashok Panigrahy
Journal:  Semin Perinatol       Date:  2015-03-03       Impact factor: 3.300

Review 5.  Pediatric brain MRI part 1: basic techniques.

Authors:  Mai-Lan Ho; Norbert G Campeau; Thang D Ngo; Unni K Udayasankar; Kirk M Welker
Journal:  Pediatr Radiol       Date:  2017-04-13

Review 6.  Acquisition guidelines and quality assessment tools for analyzing neonatal diffusion tensor MRI data.

Authors:  A M Heemskerk; A Leemans; A Plaisier; K Pieterman; M H Lequin; J Dudink
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-21       Impact factor: 3.825

Review 7.  Challenges in pediatric neuroimaging.

Authors:  Matthew J Barkovich; Yi Li; Rahul S Desikan; A James Barkovich; Duan Xu
Journal:  Neuroimage       Date:  2018-04-22       Impact factor: 6.556

8.  A highly decoupled transmit-receive array design with triangular elements at 7T.

Authors:  Gang Chen; Bei Zhang; Martijn A Cloos; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2018-03-23       Impact factor: 4.668

Review 9.  Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging.

Authors:  Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2018-08-04

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.