Literature DB >> 23516332

Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Nikolai I Avdievich1.   

Abstract

The paper describes technological advances in high-field (7 T) transceiver-phased arrays developed for magnetic resonance imaging of the human brain. The first part of this work describes an 8-element inductively decoupled split elliptical transceiver-phased array with selectable geometry, which provides an easy and efficient way of compensating for changes in mutual inductive coupling associated with difference in loading due to variability in head shape and size. The second part of the work describes a double-row 16-element (2 × 8) transceiver array to extend the homogeneous transmit B1 profile in the longitudinal direction. Multiplexing eight transmit channels between the two rows of the array provides homogeneous excitation over the entire volume. The final section describes design and construction of a double-tuned 31P/1H 16-element (8 at each frequency) array. The array improves transmission efficiency and B1 homogeneity at 1H frequency in comparison with 31P/1H quadrature transverse electromagnetic volume coil. For 31P studies, the array also improves transmission efficiency (38%), signal-to-noise ratio (SNR) for central brain locations (20%) and provides substantially greater SNR (up to 400%) for peripheral locations.

Entities:  

Year:  2011        PMID: 23516332      PMCID: PMC3600590          DOI: 10.1007/s00723-011-0280-y

Source DB:  PubMed          Journal:  Appl Magn Reson        ISSN: 0937-9347            Impact factor:   0.831


  20 in total

1.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

2.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

3.  Phantom design method for high-field MRI human systems.

Authors:  Qing X Yang; Jinghua Wang; Christopher M Collins; Michael B Smith; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

4.  Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T.

Authors:  Robert G Pinkerton; Enzo A Barberi; Ravi S Menon
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

5.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

6.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

7.  Double resonant quadrature birdcage.

Authors:  J R Fitzsimmons; B L Beck; H R Brooker
Journal:  Magn Reson Med       Date:  1993-07       Impact factor: 4.668

8.  Radiative losses of a birdcage resonator.

Authors:  M D Harpen
Journal:  Magn Reson Med       Date:  1993-05       Impact factor: 4.668

9.  Two configurations of the four-ring birdcage coil for 1H imaging and 1H-decoupled 31P spectroscopy of the human head.

Authors:  J Murphy-Boesch; R Srinivasan; L Carvajal; T R Brown
Journal:  J Magn Reson B       Date:  1994-02

10.  7T head volume coils: improvements for rostral brain imaging.

Authors:  Nikolai I Avdievich; Hoby P Hetherington; Andrey M Kuznetsov; Jullie W Pan
Journal:  J Magn Reson Imaging       Date:  2009-02       Impact factor: 4.813

View more
  28 in total

1.  Numerical and experimental evaluation of RF shimming in the human brain at 9.4 T using a dual-row transmit array.

Authors:  Jens Hoffmann; Gunamony Shajan; Klaus Scheffler; Rolf Pohmann
Journal:  MAGMA       Date:  2013-11-26       Impact factor: 2.310

2.  Neuropil pruning in Early-Course Schizophrenia: Immunological, Clinical, and Neurocognitive Correlates.

Authors:  Konasale M Prasad; Ashley M Burgess; Matcheri S Keshavan; Vishwajit L Nimgaonkar; Jeffrey A Stanley
Journal:  Biol Psychiatry Cogn Neurosci Neuroimaging       Date:  2016-11

3.  Real-time assessment of potential peak local specific absorption rate value without phase monitoring: Trigonometric maximization method for worst-case local specific absorption rate determination.

Authors:  Ettore Flavio Meliadò; Alessandro Sbrizzi; Cornelis A T van den Berg; Peter R Luijten; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2020-12-22       Impact factor: 4.668

4.  A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-08

5.  Magnetic wall decoupling method for monopole coil array in ultrahigh field MRI: a feasibility test.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Quant Imaging Med Surg       Date:  2014-04

6.  Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.

Authors:  Brian J Lee; Ronald D Watkins; Keum Sil Lee; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2018-09-09       Impact factor: 4.668

7.  Simulation verification of SNR and parallel imaging improvements by ICE-decoupled loop array in MRI.

Authors:  Xinqiang Yan; Zhipeng Cao; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2016-02-29       Impact factor: 0.831

8.  Decoupling and matching network for monopole antenna arrays in ultrahigh field MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2015-08

9.  Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Rong Xue; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2016-07-25       Impact factor: 2.546

10.  Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Authors:  Nikolai I Avdievich; Jullie W Pan; Hoby P Hetherington
Journal:  NMR Biomed       Date:  2013-06-18       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.