OBJECTIVE: We propose a novel flexible and entirely stretchable radiofrequency coil for magnetic resonance imaging. This coil design aims at increasing patient comfort during imaging while maintaining or improving image quality.
METHODS: Conductive silver-coated thread was zigzag stitched onto stretchable athletic fabric to create a single-loop receive coil. The stitched coil was mounted in draped and stretched fashions and compared to a coil fabricated on flexible printed circuit board. Match/tune circuits, detuning circuits, and baluns were incorporated into the final setup for bench measurements and imaging on a 3T MR scanner. A fast spin echo sequence was used to obtain images for comparison.
RESULTS: The fabricated coil presents multi-directional stretchability and flexibility while maintaining conductivity and stitch integrity. SNR calculations show that this stretchable coil design is comparable to a flexible, standard PCB coil with a 13-30% decrease in SNR depending on stretch degree and direction. In vivo human wrist images were obtained using the stitched coil.
CONCLUSION: Despite the reduction in SNR for this combination of materials, there is a reduced percentage of SNR drop as compared to existing stretch coil designs. These imaging results and calculations support further experimentation into more complex coil geometries. SIGNIFICANCE: This coil is uniquely stretchable in all directions, allowing for joint imaging at various degrees of flexion, while offering the closest proximity of placement to the skin. The materials provide a similar level of comfort to athletic wear and could be incorporated into coils for a variety of anatomies.

Entities:  

Mesh:

Year:  2019        PMID: 31794385      PMCID: PMC7253317          DOI: 10.1109/TBME.2019.2956682

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  16 in total

Review 1.  Magnetic resonance imaging of the knee: optimizing 3 Tesla imaging.

Authors:  Lauren Shapiro; Ernesto Staroswiecki; Garry Gold
Journal:  Semin Roentgenol       Date:  2010-10       Impact factor: 0.800

2.  MR imaging of healthy knees in varying degrees of flexion using a stretchable coil array provides comparable image quality compared to a standard knee coil array.

Authors:  Jurek A Nordmeyer-Massner; Klaas P Pruessmann; Michael Wyss; Andrei Manoliu; Jürg Hodler; Gustav Andreisek; Nadja Mamisch-Saupe
Journal:  Eur J Radiol       Date:  2015-12-18       Impact factor: 3.528

3.  ICE decoupling technique for RF coil array designs.

Authors:  Ye Li; Zhentian Xie; Yong Pang; Daniel Vigneron; Xiaoliang Zhang
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  A PIN diode controlled dual-tuned MRI RF coil and phased array for multi nuclear imaging.

Authors:  Seunghoon Ha; Mark J Hamamura; Orhan Nalcioglu; L Tugan Muftuler
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

5.  Resonant inductive decoupling (RID) for transceiver arrays to compensate for both reactive and resistive components of the mutual impedance.

Authors:  Nikolai I Avdievich; Jullie W Pan; Hoby P Hetherington
Journal:  NMR Biomed       Date:  2013-06-18       Impact factor: 4.044

6.  RF shimming for spectroscopic localization in the human brain at 7 T.

Authors:  Hoby P Hetherington; Nikolai I Avdievich; Andrey M Kuznetsov; Jullie W Pan
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

7.  Stitching Stretchable Radiofrequency Coils for MRI: A Conductive Thread and Athletic Fabric Approach.

Authors:  Jana M Vincent; Joseph V Rispoli
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

8.  Adsorbed Eutectic GaIn Structures on a Neoprene Foam for Stretchable MRI Coils.

Authors:  Matija Varga; Andreas Mehmann; Josip Marjanovic; Jonas Reber; Christian Vogt; Klaas Paul Pruessmann; Gerhard Tröster
Journal:  Adv Mater       Date:  2017-10-13       Impact factor: 30.849

9.  On the Bending and Stretching of Liquid Metal Receive Coils for Magnetic Resonance Imaging.

Authors:  Andreas Mehmann; Matija Varga; Christian Vogt; Andreas Port; Jonas Reber; Josip Marjanovic; Klaas Paul Pruessmann; Gerhard Troster
Journal:  IEEE Trans Biomed Eng       Date:  2018-10-11       Impact factor: 4.538

10.  Automated tuning of an eight-channel cardiac transceive array at 7 tesla using piezoelectric actuators.

Authors:  Graeme A Keith; Christopher T Rodgers; Aaron T Hess; Carl J Snyder; J Thomas Vaughan; Matthew D Robson
Journal:  Magn Reson Med       Date:  2014-07-01       Impact factor: 4.668

View more
  2 in total

1.  Twenty-four-channel high-impedance glove array for hand and wrist MRI at 3T.

Authors:  Bei Zhang; Bili Wang; Justin Ho; Shota Hodono; Christopher Burke; Riccardo Lattanzi; Markus Vester; Robert Rehner; Daniel Sodickson; Ryan Brown; Martijn Cloos
Journal:  Magn Reson Med       Date:  2021-12-31       Impact factor: 4.668

2.  A flexible MRI coil based on a cable conductor and applied to knee imaging.

Authors:  Bili Wang; Syed S Siddiq; Jerzy Walczyk; Mary Bruno; Iman Khodarahmi; Inge M Brinkmann; Robert Rehner; Karthik Lakshmanan; Jan Fritz; Ryan Brown
Journal:  Sci Rep       Date:  2022-09-02       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.