Literature DB >> 21859008

ICE decoupling technique for RF coil array designs.

Ye Li1, Zhentian Xie, Yong Pang, Daniel Vigneron, Xiaoliang Zhang.   

Abstract

PURPOSE: Parallel magnetic resonance imaging (MRI) requires an array of RF coil elements with different sensitivity distributions and with minimal electromagnetic coupling. The goal of this project was to develop a new method based on induced current compensation or elimination (ICE) for improved coil element decoupling and to investigate its performance in phantom MR images.
METHODS: An electromagnetic decoupling method based on induced current compensation or elimination for nonoverlapping RF coil arrays was developed with the design criteria of high efficiency, easy implementation, and no physical connection to RF array elements. An eigenvalue/eigenvector approach was employed to analyze the decoupling mechanism and condition. A two-channel microstrip array and an eight-channel coil array were built to test the performance of the method. Following workbench tests, MR imaging experiments were performed on a 7T MR scanner.
RESULTS: The bench tests showed that both arrays achieved sufficient decoupling with a S21 less than -25 dB among the coil elements at 298 MHz. The MR phantom images demonstrated well-defined sensitivity distributions from each coil element and the unique decoupling capability of the proposed ICE decoupling technique. B1 distributions of the individual elements were also measured and calculated.
CONCLUSIONS: The theoretical analysis and experiments demonstrated the feasibility of the decoupling method for high field RF coil array designs without overlapping or direct physical connections between coil elements, which provide more flexibility for coil array design and optimization. The method offers a new approach to address the RF array decoupling issue, which is a major challenge in implementing parallel imaging.

Mesh:

Year:  2011        PMID: 21859008      PMCID: PMC3139506          DOI: 10.1118/1.3598112

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  A generalized approach to parallel magnetic resonance imaging.

Authors:  D K Sodickson; C A McKenzie
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter Kellman; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

Review 7.  Ultrahigh field magnetic resonance imaging and spectroscopy.

Authors:  Kâmil Uğurbil; Gregor Adriany; Peter Andersen; Wei Chen; Michael Garwood; Rolf Gruetter; Pierre-Gil Henry; Seong-Gi Kim; Haiying Lieu; Ivan Tkac; Tommy Vaughan; Pierre-Francoise Van De Moortele; Essa Yacoub; Xiao-Hong Zhu
Journal:  Magn Reson Imaging       Date:  2003-12       Impact factor: 2.546

8.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

9.  Coupling and decoupling theory and its application to the MRI phased array.

Authors:  Ray F Lee; Randy O Giaquinto; Christopher J Hardy
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

10.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

View more
  46 in total

1.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

2.  Image homogenization using pre-emphasis method for high field MRI.

Authors:  Ye Li; Chunsheng Wang; Baiying Yu; Daniel Vigneron; Wei Chen; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2013-08

3.  The Need and Initial Practice of Parallel Imaging and Compressed Sensing in Hyperpolarized 13C MRI in vivo.

Authors:  Eugene Milshteyn; Xiaoliang Zhang
Journal:  OMICS J Radiol       Date:  2015-08-05

4.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

5.  Sensitivity enhancement of traveling wave MRI using free local resonators: an experimental demonstration.

Authors:  Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2017-04

6.  A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-08

7.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

8.  Electromagnetic Field and Radio Frequency Circuit Co-Simulation for Magnetic Resonance Imaging Dual-Tuned Radio Frequency Coils.

Authors:  Nan Li; Shengping Liu; Xiaoqing Hu; Chao Luo; Xiaoliang Zhang; Ye Li
Journal:  IEEE Trans Magn       Date:  2017-10-16       Impact factor: 1.700

9.  Precompensation for mutual coupling between array elements in parallel excitation.

Authors:  Yong Pang; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-12

10.  Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Rong Xue; John C Gore; William A Grissom
Journal:  Magn Reson Imaging       Date:  2016-07-25       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.