BACKGROUND AND
OBJECTIVE: Acetabular cup orientation, consisting of pelvic positioning, version and inclination, can influence short-term and long-term results after total hip arthroplasty (THA). The radiographic measurement of acetabular cup inclination represents an indicator of quality for the EndoCert certification in Germany. The purpose of this study was to determine the intrarater and interrater reliability of radiographic measurements of acetabular cup inclination after THA.
MATERIAL AND METHODS: In this study four independent investigators with different levels of expertise retrospectively performed measurements on radiograms (anteroposterior pelvic radiogram) from 99 patients. The intraclass correlation coefficient (ICC) and Pearson's correlation coefficient were determined and were considered statistically significant with r > 0.8 and p < 0.05. RESULTS AND
CONCLUSION: A high correlation was found for both intrarater and interrater reliability based on determination of Pearson's correlation coefficient and the ICC with r > 0.9 and p < 0.001 for all measurements. Based on these results the radiographic measurement of acetabular cup inclination can be considered as a simple measuring tool with high intrarater and interrater reliability. As cup orientation consists of inclination, version and positioning, the exclusive measurement of cup inclination for radiological quality assessment needs to be discussed critically.

Entities:  

Keywords:  Acetabular cup inclination; EndoCert; Hip joint; Joint replacement surgery; Radiologic measurement parameter

Mesh:

Year:  2018        PMID: 30143824     DOI: 10.1007/s00132-018-3628-2

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  23 in total

1.  Effect of restoration of combined offset on stability of large head THA.

Authors:  Michael Robinson; Lindsey Bornstein; Brandon Mennear; Mathias Bostrom; Bryan Nestor; Douglas Padgett; Geoffrey Westrich
Journal:  Hip Int       Date:  2012 May-Jun       Impact factor: 2.135

Review 2.  Impingement with total hip replacement.

Authors:  Aamer Malik; Aditya Maheshwari; Lawrence D Dorr
Journal:  J Bone Joint Surg Am       Date:  2007-08       Impact factor: 5.284

3.  Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Authors:  Ming Lu; Yi-Xin Zhou; Hui Du; Ji Zhang; Jian Liu
Journal:  Clin Orthop Relat Res       Date:  2013-05-04       Impact factor: 4.176

4.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

5.  Dislocation after total hip arthroplasty. Causes and prevention.

Authors:  D E McCollum; W J Gray
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

6.  Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.

Authors:  Jia-Liang Tian; Li Sun; Rui-Yin Hu; Wei Han; Xiao-Bin Tian
Journal:  Orthop Surg       Date:  2017-05-30       Impact factor: 2.071

7.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

8.  Polyethylene wear and acetabular component orientation.

Authors:  Shantanu Patil; Arnie Bergula; Peter C Chen; Clifford W Colwell; Darryl D D'Lima
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

9.  Dislocations after total hip arthroplasty.

Authors:  R Y Woo; B F Morrey
Journal:  J Bone Joint Surg Am       Date:  1982-12       Impact factor: 5.284

10.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.