Literature DB >> 21938375

A reliability study of measurement tools available on standard picture archiving and communication system workstations for the evaluation of hip radiographs following arthroplasty.

Sanjay R Patel1, Andoni P Toms, Javed M Rehman, James Wimhurst.   

Abstract

BACKGROUND: Conventional radiography is the primary imaging tool for routine follow-up of total hip replacements, but the reliability of this method has been questioned. The aim of this study was to assess the reliability of commonly used measurements of the position of hip prostheses on postoperative radiographs with use of tools available on all standard picture archiving and communication system workstations.
METHODS: Fifty anteroposterior pelvic and lateral hip radiographs that were made after a unilateral total hip arthroplasty were included in this study. Acetabular inclination, lateral offset, lower-limb length, center of rotation, and femoral stem angle were independently assessed by two observers. Intraclass correlation coefficients were calculated for each measurement.
RESULTS: The results demonstrated excellent reliability for acetabular angle (r = 0.95), lower-limb length (r = 0.91), and lateral offset (r = 0.95) measurements and good reliability for center of rotation (r = 0.73) and lateral femoral stem angle (r = 0.68) measurements.
CONCLUSIONS: The position of total hip replacements can be reliably assessed with use of simple electronic tools and standard radiology workstations.

Entities:  

Mesh:

Year:  2011        PMID: 21938375     DOI: 10.2106/JBJS.J.00709

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  7 in total

1.  Total hip arthroplasty in patients with fibrous dysplasia: a modern update.

Authors:  Simon Garceau; Yaniv Warschawski; Oleg Safir; Allan Gross; Jesse Wolfstadt; Paul Kuzyk
Journal:  Can J Surg       Date:  2020-05-01       Impact factor: 2.089

2.  The withdrawn ASR™ THA and hip resurfacing systems: how have our patients fared over 1 to 6 years?

Authors:  Kevin T Hug; Tyler S Watters; Thomas P Vail; Michael P Bolognesi
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

3.  Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Authors:  Ming Lu; Yi-Xin Zhou; Hui Du; Ji Zhang; Jian Liu
Journal:  Clin Orthop Relat Res       Date:  2013-05-04       Impact factor: 4.176

4.  Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty.

Authors:  Sarwar S Mahmood; Bariq Al-Amiry; Sebastian S Mukka; Saida Baea; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2014-11-18       Impact factor: 2.199

5.  Restoring femoral offset and leg length; the potential of a short curved stem in total hip arthroplasty.

Authors:  Thom E Snijders; Joost H J van Erp; Arthur de Gast
Journal:  J Orthop       Date:  2019-05-02

6.  Association between changes in global femoral offset after total hip arthroplasty and function, quality of life, and abductor muscle strength. A prospective cohort study of 222 patients.

Authors:  Sarwar S Mahmood; Sebastian S Mukka; Sead Crnalic; Per Wretenberg; Arkan S Sayed-Noor
Journal:  Acta Orthop       Date:  2015-10-16       Impact factor: 3.717

7.  Restoration of the hip geometry after two-stage exchange with intermediate resection arthroplasty for periprosthetic joint infection.

Authors:  Jan Hubert; Frank Timo Beil; Tim Rolvien; Christian Ries; Stephan Frosch; Dominik Saul; Thelonius Hawellek
Journal:  Sci Rep       Date:  2021-03-04       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.