Literature DB >> 25202657

A monopole/loop dual-tuned RF coil for ultrahigh field MRI.

Xinqiang Yan1, Rong Xue1, Xiaoliang Zhang1.   

Abstract

Proton and heteronuclear MRI/MRS using dual-tuned (DT) coils could provide both anatomical and metabolic images without repositioning the subject. However, it is technologically challenging to attain sufficiently electromagnetic (EM) decoupling between the heteronuclear channel and proton channel, and keep the imaging areas and profiles of two nuclear channels highly matched. In this study, a hybrid monopole/loop technique was proposed for DT coil design and this technique was validated by implementing and testing a DT (1)H/(23)Na coil for MR imaging at 7T. The RF fields of the monopole ((1)H channel) and regular L/C loop ((23)Na channel) were orthogonal and intrinsically EM decoupled. Bench measurement results demonstrated the isolation between the two nuclear channels was better than -28 dB at both nuclear frequencies. Compared with the conventional DT coil using trap circuits, the monopole/loop DT coil had higher MR sensitivity for sodium imaging. The experimental results indicated that the monopole/loop technique might be a simple and efficient design for multinuclear imaging at ultrahigh fields. Additionally, the proposed DT coils based on the monopole/loop technique can be used as building blocks in designing multichannel DT coil arrays.

Entities:  

Keywords:  Magnetic resonance image (MRI); decouple; dual-tuned (DT); loop; monopole; radiofrequency coil; sensitivity; signal-to-noise ratio (SNR); sodium; trap

Year:  2014        PMID: 25202657      PMCID: PMC4137181          DOI: 10.3978/j.issn.2223-4292.2014.08.03

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  33 in total

1.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

2.  Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1T.

Authors:  Xiaozhong Zhang; Andrew Webb
Journal:  J Magn Reson       Date:  2004-09       Impact factor: 2.229

3.  Design of an inductively decoupled microstrip array at 9.4 T.

Authors:  Bing Wu; Xiaoliang Zhang; Peng Qu; Gary X Shen
Journal:  J Magn Reson       Date:  2006-07-07       Impact factor: 2.229

4.  An improved trap design for decoupling multinuclear RF coils.

Authors:  Martin Meyerspeer; Eulalia Serés Roig; Rolf Gruetter; Arthur W Magill
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

5.  Alzheimer dementia: quantification of energy metabolism and mobile phosphoesters with P-31 NMR spectroscopy.

Authors:  P A Bottomley; J P Cousins; D L Pendrey; W A Wagle; C J Hardy; F A Eames; R J McCaffrey; D A Thompson
Journal:  Radiology       Date:  1992-06       Impact factor: 11.105

6.  A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Authors:  Chunsheng Wang; Ye Li; Bing Wu; Duan Xu; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

7.  Detecting natural abundance carbon signal of NAA metabolite within 12-cm3 localized volume of human brain using 1H-[13C] NMR spectroscopy.

Authors:  W Chen; G Adriany; X H Zhu; R Gruetter; K Ugurbil
Journal:  Magn Reson Med       Date:  1998-08       Impact factor: 4.668

8.  Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging.

Authors:  Ryan Brown; Guillaume Madelin; Riccardo Lattanzi; Gregory Chang; Ravinder R Regatte; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2012-08-08       Impact factor: 4.668

9.  In vivo 31P magnetic resonance spectroscopy of human brain at 7 T: an initial experience.

Authors:  Hao Lei; Xiao-Hong Zhu; Xiao-Liang Zhang; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

10.  Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Authors:  Nikolai I Avdievich
Journal:  Appl Magn Reson       Date:  2011-12       Impact factor: 0.831

View more
  9 in total

1.  The Need and Initial Practice of Parallel Imaging and Compressed Sensing in Hyperpolarized 13C MRI in vivo.

Authors:  Eugene Milshteyn; Xiaoliang Zhang
Journal:  OMICS J Radiol       Date:  2015-08-05

Review 2.  Quantitative sodium MR imaging: A review of its evolving role in medicine.

Authors:  Keith R Thulborn
Journal:  Neuroimage       Date:  2016-11-24       Impact factor: 6.556

3.  Decoupling and matching network for monopole antenna arrays in ultrahigh field MRI.

Authors:  Xinqiang Yan; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2015-08

4.  Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T.

Authors:  Xinqiang Yan; Long Wei; Suoda Chu; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2016-04-07       Impact factor: 0.831

5.  Hybrid monopole/loop coil array for human head MR imaging at 7T.

Authors:  Xinqiang Yan; Long Wei; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2015-05-01       Impact factor: 0.831

6.  Multichannel Double-Row Transmission Line Array for Human MR Imaging at Ultrahigh Fields.

Authors:  Xinqiang Yan; Jan Ole Pedersen; Long Wei; Xiaoliang Zhang; Rong Xue
Journal:  IEEE Trans Biomed Eng       Date:  2015-02-18       Impact factor: 4.538

7.  A Review of Non-1H RF Receive Arrays in Magnetic Resonance Imaging and Spectroscopy.

Authors:  Matthew Wilcox; Steven M Wright; Mary McDougall
Journal:  IEEE Open J Eng Med Biol       Date:  2020-10-13

8.  High-resolution intravascular magnetic resonance imaging of the coronary artery wall at 3.0 Tesla: toward evaluation of atherosclerotic plaque vulnerability.

Authors:  Yanfeng Meng; Zhiguang Mo; Jinying Hao; Yueyou Peng; Hui Yan; Jingbo Mu; Dengfeng Ma; Xiaoliang Zhang; Ye Li
Journal:  Quant Imaging Med Surg       Date:  2021-11

9.  Closely-spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields.

Authors:  Xinqiang Yan; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2015-06-30       Impact factor: 0.831

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.