Literature DB >> 8396709

Double resonant quadrature birdcage.

J R Fitzsimmons1, B L Beck, H R Brooker.   

Abstract

The combined acquisition of proton images and localized spectra is considered essential to the application of NMR techniques to human and animal research. The ideal imaging/spectroscopy coil for our purposes would be one that provides the highest possible signal-to-noise, high homogeneity, and operation on two or more frequencies without retuning requirements or cable changes. To address these needs we have developed a quadrature double-tuned birdcage. We have incorporated our earlier work on the transformer coupled double-tuned surface coil into the birdcage structure by placing two birdcages in a coaxial configuration. This structure resonates at 34.6 MHz (phosphorus resonance at 2.0 T) and 85.5 MHz (proton resonance at 2.0 T). The quadrature performance of this coil for phosphorus was excellent, with a signal-to-noise that was 133% of our linear reference. The proton performance was less efficient, with a signal to noise that was 67% of our linear reference, but still quite sufficient for imaging. A phosphorus spectra and proton image of a rat abdomen are shown.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8396709     DOI: 10.1002/mrm.1910300116

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  Dual resonant birdcage coils for 1H detected 13C microscopic imaging at 11.7 T.

Authors:  A M Hudson; W Köckenberger; R W Bowtell
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

3.  A practical multinuclear transceiver volume coil for in vivo MRI/MRS at 7 T.

Authors:  Chunsheng Wang; Ye Li; Bing Wu; Duan Xu; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Magn Reson Imaging       Date:  2011-11-03       Impact factor: 2.546

4.  Design of a nested eight-channel sodium and four-channel proton coil for 7T knee imaging.

Authors:  Ryan Brown; Guillaume Madelin; Riccardo Lattanzi; Gregory Chang; Ravinder R Regatte; Daniel K Sodickson; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2012-08-08       Impact factor: 4.668

Review 5.  High-performance radiofrequency coils for (23)Na MRI: brain and musculoskeletal applications.

Authors:  Graham C Wiggins; Ryan Brown; Karthik Lakshmanan
Journal:  NMR Biomed       Date:  2015-09-24       Impact factor: 4.044

6.  Optimization and comparison of two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging.

Authors:  Gunthard Lykowsky; Flavio Carinci; Markus Düring; Daniel Weber; Peter M Jakob; Daniel Haddad
Journal:  Quant Imaging Med Surg       Date:  2015-12

7.  Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy.

Authors:  Wm Potter; L Wang; Kk McCully; Q Zhao
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2013-08-01       Impact factor: 1.176

8.  A flexible nested sodium and proton coil array with wideband matching for knee cartilage MRI at 3T.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Leeor Alon; Gregory Chang; Daniel K Sodickson; Ravinder R Regatte; Graham C Wiggins
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

9.  Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Authors:  Nikolai I Avdievich
Journal:  Appl Magn Reson       Date:  2011-12       Impact factor: 0.831

10.  Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Authors:  Omar Rutledge; Tiffany Kwak; Peng Cao; Xiaoliang Zhang
Journal:  J Magn Reson       Date:  2016-04-07       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.