Literature DB >> 16032690

Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T.

Robert G Pinkerton1, Enzo A Barberi, Ravi S Menon.   

Abstract

As the static magnetic field strength used in human magnetic resonance imaging increases, the wavelength of the corresponding radiofrequency field becomes comparable to the dimensions of the coil and volume of interest. The dielectric resonance effects that arise in this full wavelength regime may be partially compensated for through the use of surface coils. A novel high-field (4 T) transceive surface coil array is presented that allows arbitrary surface coil placement and size while maintaining the ability to independently transmit and/or receive through conventional 50-ohm power amplifiers and preamplifiers, respectively. A ninefold signal-to-noise ratio (SNR) increase is shown in close proximity to the transceive array and there is an overall 38% increase throughout the entire brain volume in comparison to the standard hybrid birdcage coil. Furthermore, the ability to independently transmit and receive through each surface coil within this array enables transmit and/or receive-only fast parallel imaging techniques to be employed while maintaining the increased SNR sensitivity inherent to surface coil designs. 2005 Wiley-Liss, Inc

Entities:  

Mesh:

Year:  2005        PMID: 16032690     DOI: 10.1002/mrm.20583

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Multiple-Input Multiple-Output (MIMO) MRI: Combining Parallel Excitation and Parallel Reception for Enhanced Imaging.

Authors:  Xianglun Mao; Nicole L Vike; Thomas M Talavage; Joseph V Rispoli; David J Love
Journal:  IEEE Trans Comput Imaging       Date:  2019-03-13

2.  Design and Test of Magnetic Wall Decoupling for Dipole Transmit/Receive Array for MR Imaging at the Ultrahigh Field of 7T.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Appl Magn Reson       Date:  2014-11-27       Impact factor: 0.831

3.  Magnetic wall decoupling method for monopole coil array in ultrahigh field MRI: a feasibility test.

Authors:  Xinqiang Yan; Xiaoliang Zhang; Long Wei; Rong Xue
Journal:  Quant Imaging Med Surg       Date:  2014-04

4.  Performance evaluation of RF coils integrated with an RF-penetrable PET insert for simultaneous PET/MRI.

Authors:  Brian J Lee; Ronald D Watkins; Keum Sil Lee; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2018-09-09       Impact factor: 4.668

5.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

6.  Experimental implementation of array-compressed parallel transmission at 7 tesla.

Authors:  Xinqiang Yan; Zhipeng Cao; William A Grissom
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

7.  Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T.

Authors:  Xinqiang Yan; Long Wei; Suoda Chu; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2016-04-07       Impact factor: 0.831

8.  Hybrid monopole/loop coil array for human head MR imaging at 7T.

Authors:  Xinqiang Yan; Long Wei; Rong Xue; Xiaoliang Zhang
Journal:  Appl Magn Reson       Date:  2015-05-01       Impact factor: 0.831

9.  Multichannel Double-Row Transmission Line Array for Human MR Imaging at Ultrahigh Fields.

Authors:  Xinqiang Yan; Jan Ole Pedersen; Long Wei; Xiaoliang Zhang; Rong Xue
Journal:  IEEE Trans Biomed Eng       Date:  2015-02-18       Impact factor: 4.538

10.  Transceiver-Phased Arrays for Human Brain Studies at 7 T.

Authors:  Nikolai I Avdievich
Journal:  Appl Magn Reson       Date:  2011-12       Impact factor: 0.831

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.