Literature DB >> 23470288

Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study.

Y Petibon1, J Ouyang, X Zhu, C Huang, T G Reese, S Y Chun, Q Li, G El Fakhri.   

Abstract

Cardiac motion and partial volume effects (PVE) are two of the main causes of image degradation in cardiac PET. Motion generates artifacts and blurring while PVE lead to erroneous myocardial activity measurements. Newly available simultaneous PET-MR scanners offer new possibilities in cardiac imaging as MRI can assess wall contractility while collecting PET perfusion data. In this perspective, we develop a list-mode iterative reconstruction framework incorporating both tagged-MR derived non-rigid myocardial wall motion and position dependent detector point spread function (PSF) directly into the PET system matrix. In this manner, our algorithm performs both motion 'deblurring' and PSF deconvolution while reconstructing images with all available PET counts. The proposed methods are evaluated in a beating non-rigid cardiac phantom whose hot myocardial compartment contains small transmural and non-transmural cold defects. In order to accelerate imaging time, we investigate collecting full and half k-space tagged MR data to obtain tagged volumes that are registered using non-rigid B-spline registration to yield wall motion information. Our experimental results show that tagged-MR based motion correction yielded an improvement in defect/myocardium contrast recovery of 34-206% as compared to motion uncorrected studies. Likewise, lesion detectability improved by respectively 115-136% and 62-235% with MR-based motion compensation as compared to gating and no motion correction and made it possible to distinguish non-transmural from transmural defects, which has clinical significance given the inherent limitations of current single modality imaging in identifying the amount of residual ischemia. The incorporation of PSF modeling within the framework of MR-based motion compensation significantly improved defect/myocardium contrast recovery (5.1-8.5%, p < 0.01) and defect detectability (39-56%, p < 0.01). No statistical difference was found in PET contrast and lesion detectability based on motion fields obtained with half and full k-space tagged data.

Entities:  

Mesh:

Year:  2013        PMID: 23470288      PMCID: PMC3657754          DOI: 10.1088/0031-9155/58/7/2085

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  40 in total

1.  Four-dimensional processing of deformable cardiac PET data.

Authors:  Gregory J Klein; Ronald H Huesman
Journal:  Med Image Anal       Date:  2002-03       Impact factor: 8.545

2.  "Motion-frozen" display and quantification of myocardial perfusion.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Xingping Kang; Cigdem Akincioglu; John D Friedman; Sean W Hayes; Usaf E Aladl; Guido Germano
Journal:  J Nucl Med       Date:  2004-07       Impact factor: 10.057

3.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

4.  Channelized-ideal observer using Laguerre-Gauss channels in detection tasks involving non-Gaussian distributed lumpy backgrounds and a Gaussian signal.

Authors:  Subok Park; Harrison H Barrett; Eric Clarkson; Matthew A Kupinski; Kyle J Myers
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

5.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

6.  Quantitative PET comparing gated with nongated acquisitions using a NEMA phantom with respiratory-simulated motion.

Authors:  Douglass C Vines; Harald Keller; Jeremy D P Hoisak; Stephen L Breen
Journal:  J Nucl Med Technol       Date:  2007-11-15

7.  Modeling and incorporation of system response functions in 3-D whole body PET.

Authors:  Adam M Alessio; Paul E Kinahan; Thomas K Lewellen
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

8.  Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images.

Authors:  W G O'Dell; C C Moore; W C Hunter; E A Zerhouni; E R McVeigh
Journal:  Radiology       Date:  1995-06       Impact factor: 11.105

9.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

10.  Motion correction in dual gated cardiac PET using mass-preserving image registration.

Authors:  Fabian Gigengack; Lars Ruthotto; Martin Burger; Carsten H Wolters; Xiaoyi Jiang; Klaus P Schäfers
Journal:  IEEE Trans Med Imaging       Date:  2011-11-09       Impact factor: 10.048

View more
  28 in total

Review 1.  Combined PET/MRI: Multi-modality Multi-parametric Imaging Is Here: Summary Report of the 4th International Workshop on PET/MR Imaging; February 23-27, 2015, Tübingen, Germany.

Authors:  D L Bailey; B J Pichler; B Gückel; H Barthel; A J Beer; J Bremerich; J Czernin; A Drzezga; C Franzius; V Goh; M Hartenbach; H Iida; A Kjaer; C la Fougère; C N Ladefoged; I Law; K Nikolaou; H H Quick; O Sabri; J Schäfer; M Schäfers; H F Wehrl; T Beyer
Journal:  Mol Imaging Biol       Date:  2015-10       Impact factor: 3.488

2.  Comparative analysis of iterative reconstruction algorithms with resolution recovery and time of flight modeling for 18F-FDG cardiac PET: A multi-center phantom study.

Authors:  Roberta Matheoud; Michela Lecchi; Domenico Lizio; Camilla Scabbio; Claudio Marcassa; Lucia Leva; Angelo Del Sole; Carlo Rodella; Luca Indovina; Christian Bracco; Marco Brambilla; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-01-12       Impact factor: 5.952

3.  Do myocardial PET-MR and PET-CT FDG images provide comparable information?

Authors:  Jorge D Oldan; Shetal N Shah; Richard C Brunken; Frank P DiFilippo; Nancy A Obuchowski; Michael A Bolen
Journal:  J Nucl Cardiol       Date:  2015-06-13       Impact factor: 5.952

4.  Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Authors:  Chuan Huang; Yoann Petibon; Jinsong Ouyang; Timothy G Reese; Mark A Ahlman; David A Bluemke; Georges El Fakhri
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

5.  Quantitative simultaneous positron emission tomography and magnetic resonance imaging.

Authors:  Jinsong Ouyang; Yoann Petibon; Chuan Huang; Timothy G Reese; Aleksandra L Kolnick; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

Review 6.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

7.  Imaging moving heart structures with PET.

Authors:  Piotr J Slomka; Tinsu Pan; Guido Germano
Journal:  J Nucl Cardiol       Date:  2015-03-26       Impact factor: 5.952

8.  MR-based motion correction for PET imaging using wired active MR microcoils in simultaneous PET-MR: phantom study.

Authors:  Chuan Huang; Jerome L Ackerman; Yoann Petibon; Thomas J Brady; Georges El Fakhri; Jinsong Ouyang
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

9.  4D numerical observer for lesion detection in respiratory-gated PET.

Authors:  Auranuch Lorsakul; Quanzheng Li; Cathryn M Trott; Christopher Hoog; Yoann Petibon; Jinsong Ouyang; Andrew F Laine; Georges El Fakhri
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

10.  Towards coronary plaque imaging using simultaneous PET-MR: a simulation study.

Authors:  Y Petibon; G El Fakhri; R Nezafat; N Johnson; T Brady; J Ouyang
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

View more