Literature DB >> 16827484

Modeling and incorporation of system response functions in 3-D whole body PET.

Adam M Alessio1, Paul E Kinahan, Thomas K Lewellen.   

Abstract

Appropriate application of spatially variant system models can correct for degraded resolution response and mispositioning errors. This paper explores the detector blurring component of the system model for a whole body positron emission tomography (PET) system and extends this factor into a more general system response function to account for other system effects including the influence of Fourier rebinning (FORE). We model the system response function as a three-dimensional (3-D) function that blurs in the radial and axial dimension and is spatially variant in radial location. This function is derived from Monte Carlo simulations and incorporates inter-crystal scatter, crystal penetration, and the blurring due to the FORE algorithm. The improved system model is applied in a modified ordered subsets expectation maximization (OSEM) algorithm to reconstruct images from rebinned, fully 3-D PET data. The proposed method effectively removes the spatial variance in the resolution response, as shown in simulations of point sources. Furthermore, simulation and measured studies show the proposed method improves quantitative accuracy with a reduction in tumor bias compared to conventional OSEM on the order of 10%-30% depending on tumor size and smoothing parameter.

Entities:  

Mesh:

Year:  2006        PMID: 16827484     DOI: 10.1109/tmi.2006.873222

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  42 in total

1.  Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM.

Authors:  D Wiant; J A Gersh; M Bennett; J D Bourland
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Evaluation of Noise Properties in PSF-Based PET Image Reconstruction.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

3.  Iterative reconstruction of Fourier-rebinned PET data using sinogram blurring function estimated from point source scans.

Authors:  Michel S Tohme; Jinyi Qi
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

4.  Comparative analysis of iterative reconstruction algorithms with resolution recovery and time of flight modeling for 18F-FDG cardiac PET: A multi-center phantom study.

Authors:  Roberta Matheoud; Michela Lecchi; Domenico Lizio; Camilla Scabbio; Claudio Marcassa; Lucia Leva; Angelo Del Sole; Carlo Rodella; Luca Indovina; Christian Bracco; Marco Brambilla; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-01-12       Impact factor: 5.952

5.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

6.  APPLICATION OF A SPATIALLY VARIANT SYSTEM MODEL FOR 3-D WHOLE-BODY PET IMAGE RECONSTRUCTION.

Authors:  Adam M Alessio; Paul E Kinahan
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2008-05-14

7.  Comparison between two super-resolution implementations in PET imaging.

Authors:  Guoping Chang; Tinsu Pan; Feng Qiao; John W Clark; Osama R Mawlawi
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

Review 8.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

9.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

10.  Applications of the line-of-response probability density function resolution model in PET list mode reconstruction.

Authors:  Y Jian; R Yao; T Mulnix; X Jin; R E Carson
Journal:  Phys Med Biol       Date:  2014-12-09       Impact factor: 3.609

View more