"Motion-frozen" display and quantification of myocardial perfusion.

Piotr J Slomka1, Hidetaka Nishina, Daniel S Berman, Xingping Kang, Cigdem Akincioglu, John D Friedman, Sean W Hayes, Usaf E Aladl, Guido Germano.   

Abstract

UNLABELLED: Gated myocadial perfusion SPECT (MPS) incorporates functional and perfusion information of the left ventricle (LV). To improve the image quality and accuracy of gated MPS we propose to eliminate the influence of cardiac LV motion in the display and quantification by a novel "motion-frozen" (MF) technique.
METHODS: Three-dimensional LV contours were identified on images of the individual time phases. Three-dimensional phase-to-phase motion vectors were derived by sampling of the epi- and endocardial surfaces. A nonlinear image warping (thin-plate spline) was applied to warp all image phases to fit the end-diastolic (ED) phase. Warped images were created to provide the LV image in the ED phase but containing counts from an arbitrary number of time intervals. MF quantification has been performed using the same phase-to-phase motion vectors. MF normal perfusion limits were created from (99m)Tc sestamibi gated MPS studies of 40 females and 40 males with low likelihood (<5%) of coronary artery disease. All MF processing was completely automated. In the initial evaluation, we assessed the display quality and quantification of stress images using MF processing in 51 consecutive patients with 16-frame electrocardiographic gating and available coronary angiography.
RESULTS: The display quality was significantly better for MF images as assessed visually. The MF images had the appearance of ED frames but were less noisy and of higher resolution than the summed images. MF images had higher maximum count values in the LV (116% +/- 6%) and higher contrast (12.5 +/- 7.7 vs. 9.5 +/- 3.2) than the corresponding summed images. The area under the receiver operator characteristic curve for prediction of stenoses > or = 70% by the MF method was 0.92 +/- 0.04 versus 0.89 +/- 0.04 by standard quantification (P = not significant). The computation time for automated MF quantification and warping was <25 s for each case.
CONCLUSION: We have developed a novel technique for display and quantification of gated myocardial perfusion images, which retrospectively eliminates blur due to cardiac motion. Such processing of gated MPS appears to improve the effective resolution of images. Initial evaluation indicates that it may improve the accuracy of gated MPS in detection of coronary artery disease.

Entities:  

Mesh:

Year:  2004        PMID: 15235058

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  47 in total

Review 1.  Improvement in PET myocardial perfusion image quality and quantification with flurpiridaz F 18.

Authors:  Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2012-02       Impact factor: 5.952

2.  Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT.

Authors:  Ryo Nakazato; Damini Dey; Erick Alexánderson; Aloha Meave; Moisés Jiménez; Edgar Romero; Rodrigo Jácome; Marco Peña; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2012-03-15       Impact factor: 5.952

3.  Deformable left-ventricle mesh model for motion-compensated filtering in cardiac gated SPECT.

Authors:  Thibault Marin; Jovan G Brankov
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

Review 4.  Value of coronary CTA in patients with known or suspected CAD and non-diagnostic initial myocardial perfusion testing: current evidence and clinical considerations.

Authors:  Aiden Abidov; Gilbert L Raff
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

5.  Fourth annual Mario S. Verani, MD Memorial Lecture: noninvasive imaging in coronary artery disease: changing roles, changing players.

Authors:  Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

6.  Recent technologic advances in nuclear cardiology.

Authors:  James A Patton; Piotr J Slomka; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

Review 7.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

8.  Geometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT.

Authors:  Jonghye Woo; Piotr J Slomka; Damini Dey; Victor Y Cheng; Byung-Woo Hong; Amit Ramesh; Daniel S Berman; Ronald P Karlsberg; C-C Jay Kuo; Guido Germano
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

9.  Towards coronary plaque imaging using simultaneous PET-MR: a simulation study.

Authors:  Y Petibon; G El Fakhri; R Nezafat; N Johnson; T Brady; J Ouyang
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

10.  Optimizing radiation dose and imaging time with conventional myocardial perfusion SPECT: Technical aspects.

Authors:  Piotr Slomka; Guido Germano
Journal:  J Nucl Cardiol       Date:  2016-03-08       Impact factor: 5.952