Literature DB >> 24556608

Towards coronary plaque imaging using simultaneous PET-MR: a simulation study.

Y Petibon1, G El Fakhri, R Nezafat, N Johnson, T Brady, J Ouyang.   

Abstract

Coronary atherosclerotic plaque rupture is the main cause of myocardial infarction and the leading killer in the US. Inflammation is a known bio-marker of plaque vulnerability and can be assessed non-invasively using fluorodeoxyglucose-positron emission tomography imaging (FDG-PET). However, cardiac and respiratory motion of the heart makes PET detection of coronary plaque very challenging. Fat surrounding coronary arteries allows the use of MRI to track plaque motion during simultaneous PET-MR examination. In this study, we proposed and assessed the performance of a fat-MR based coronary motion correction technique for improved FDG-PET coronary plaque imaging in simultaneous PET-MR. The proposed methods were evaluated in a realistic four-dimensional PET-MR simulation study obtained by combining patient water-fat separated MRI and XCAT anthropomorphic phantom. Five small lesions were digitally inserted inside the patients coronary vessels to mimic coronary atherosclerotic plaques. The heart of the XCAT phantom was digitally replaced with the patient's heart. Motion-dependent activity distributions, attenuation maps, and fat-MR volumes of the heart, were generated using the XCAT cardiac and respiratory motion fields. A full Monte Carlo simulation using Siemens mMR's geometry was performed for each motion phase. Cardiac/respiratory motion fields were estimated using non-rigid registration of the transformed fat-MR volumes and incorporated directly into the system matrix of PET reconstruction along with motion-dependent attenuation maps. The proposed motion correction method was compared to conventional PET reconstruction techniques such as no motion correction, cardiac gating, and dual cardiac-respiratory gating. Compared to uncorrected reconstructions, fat-MR based motion compensation yielded an average improvement of plaque-to-background contrast of 29.6%, 43.7%, 57.2%, and 70.6% for true plaque-to-blood ratios of 10, 15, 20 and 25:1, respectively. Channelized Hotelling observer (CHO) signal-to-noise ratio (SNR) was used to quantify plaque detectability. CHO-SNR improvement ranged from 105% to 128% for fat-MR-based motion correction as compared to no motion correction. Likewise, CHO-SNR improvement ranged from 348% to 396% as compared to both cardiac and dual cardiac-respiratory gating approaches. Based on this study, our approach, a fat-MR based motion correction for coronary plaque PET imaging using simultaneous PET-MR, offers great potential for clinical practice. The ultimate performance and limitation of our approach, however, must be fully evaluated in patient studies.

Entities:  

Mesh:

Year:  2014        PMID: 24556608      PMCID: PMC4061607          DOI: 10.1088/0031-9155/59/5/1203

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  39 in total

Review 1.  Clinical usefulness of respiratory variations in arterial pressure.

Authors:  Sheldon Magder
Journal:  Am J Respir Crit Care Med       Date:  2004-01-15       Impact factor: 21.405

2.  "Motion-frozen" display and quantification of myocardial perfusion.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Xingping Kang; Cigdem Akincioglu; John D Friedman; Sean W Hayes; Usaf E Aladl; Guido Germano
Journal:  J Nucl Med       Date:  2004-07       Impact factor: 10.057

3.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

4.  Fusion of positron emission tomography and coronary computed tomographic angiography identifies fluorine 18 fluorodeoxyglucose uptake in the left main coronary artery soft plaque.

Authors:  Erick Alexanderson; Piotr Slomka; Victor Cheng; Aloha Meave; Yolanda Saldaña; Leonardo García-Rojas; Daniel Berman
Journal:  J Nucl Cardiol       Date:  2008-08-09       Impact factor: 5.952

5.  Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images.

Authors:  W G O'Dell; C C Moore; W C Hunter; E A Zerhouni; E R McVeigh
Journal:  Radiology       Date:  1995-06       Impact factor: 11.105

Review 6.  Triggers, acute risk factors and vulnerable plaques: the lexicon of a new frontier.

Authors:  J E Muller; G S Abela; R W Nesto; G H Tofler
Journal:  J Am Coll Cardiol       Date:  1994-03-01       Impact factor: 24.094

7.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

8.  Coronary risk factors and plaque morphology in men with coronary disease who died suddenly.

Authors:  A P Burke; A Farb; G T Malcom; Y H Liang; J Smialek; R Virmani
Journal:  N Engl J Med       Date:  1997-05-01       Impact factor: 91.245

Review 9.  Coronary plaque erosion without rupture into a lipid core. A frequent cause of coronary thrombosis in sudden coronary death.

Authors:  A Farb; A P Burke; A L Tang; T Y Liang; P Mannan; J Smialek; R Virmani
Journal:  Circulation       Date:  1996-04-01       Impact factor: 29.690

10.  Cardiac motion compensation and resolution modeling in simultaneous PET-MR: a cardiac lesion detection study.

Authors:  Y Petibon; J Ouyang; X Zhu; C Huang; T G Reese; S Y Chun; Q Li; G El Fakhri
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

View more
  16 in total

1.  Do myocardial PET-MR and PET-CT FDG images provide comparable information?

Authors:  Jorge D Oldan; Shetal N Shah; Richard C Brunken; Frank P DiFilippo; Nancy A Obuchowski; Michael A Bolen
Journal:  J Nucl Cardiol       Date:  2015-06-13       Impact factor: 5.952

2.  Quantitative simultaneous positron emission tomography and magnetic resonance imaging.

Authors:  Jinsong Ouyang; Yoann Petibon; Chuan Huang; Timothy G Reese; Aleksandra L Kolnick; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

Review 3.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

4.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

Review 5.  Diagnostic imaging in the management of patients with metabolic syndrome.

Authors:  Seo Rin Kim; Lilach O Lerman
Journal:  Transl Res       Date:  2017-11-22       Impact factor: 7.012

6.  MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging.

Authors:  Y Petibon; T Sun; P K Han; C Ma; G El Fakhri; J Ouyang
Journal:  Phys Med Biol       Date:  2019-10-04       Impact factor: 3.609

7.  Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.

Authors:  Yoann Petibon; Yothin Rakvongthai; Georges El Fakhri; Jinsong Ouyang
Journal:  Phys Med Biol       Date:  2017-04-05       Impact factor: 3.609

Review 8.  Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

Authors:  Yothin Rakvongthai; Georges El Fakhri
Journal:  PET Clin       Date:  2017-07

Review 9.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

Review 10.  Molecular imaging of plaques in coronary arteries with PET and SPECT.

Authors:  Zhong-Hua Sun; Hairil Rashmizal; Lei Xu
Journal:  J Geriatr Cardiol       Date:  2014-09       Impact factor: 3.327

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.