Literature DB >> 21179392

A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Se Young Chun1, Jeffrey A Fessler.   

Abstract

Nonrigid image registration is an important task for many medical imaging applications. In particular, for radiation oncology it is desirable to track respiratory motion for thoracic cancer treatment. B-splines are convenient for modeling nonrigid deformations, but ensuring invertibility can be a challenge. This paper describes sufficient conditions for local invertibility of deformations based on B-spline bases. These sufficient conditions can be used with constrained optimization to enforce local invertibility. We also incorporate these conditions into nonrigid image registration methods based on a simple penalty approach that encourages diffeomorphic deformations. Traditional Jacobian penalty methods penalize negative Jacobian determinant values only at grid points. In contrast, our new method enforces a sufficient condition for invertibility directly on the deformation coefficients to encourage invertibility globally over a 3D continuous domain. The proposed penalty approach requires substantially less compute time than Jacobian penalties per iteration.

Entities:  

Year:  2009        PMID: 21179392      PMCID: PMC3004236          DOI: 10.1109/JSTSP.2008.2011116

Source DB:  PubMed          Journal:  IEEE J Sel Top Signal Process        ISSN: 1932-4553            Impact factor:   6.856


  21 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint.

Authors:  Torsten Rohlfing; Calvin R Maurer; David A Bluemke; Michael A Jacobs
Journal:  IEEE Trans Med Imaging       Date:  2003-06       Impact factor: 10.048

3.  3-D deformable image registration: a topology preservation scheme based on hierarchical deformation models and interval analysis optimization.

Authors:  Vincent Noblet; Christian Heinrich; Fabrice Heitz; Jean-Paul Armspach
Journal:  IEEE Trans Image Process       Date:  2005-05       Impact factor: 10.856

4.  Respiratory motion correction for PET oncology applications using affine transformation of list mode data.

Authors:  F Lamare; T Cresson; J Savean; C Cheze Le Rest; A J Reader; D Visvikis
Journal:  Phys Med Biol       Date:  2006-12-12       Impact factor: 3.609

5.  Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

6.  A fast nonrigid image registration with constraints on the Jacobian using large scale constrained optimization.

Authors:  Michaël Sdika
Journal:  IEEE Trans Med Imaging       Date:  2008-02       Impact factor: 10.048

7.  Topology preserving deformable image matching using constrained hierarchical parametric models.

Authors:  O Musse; F Heitz; J P Armspach
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

8.  Fast parametric elastic image registration.

Authors:  Jan Kybic; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

9.  Diffeomorphic registration using B-splines.

Authors:  Daniel Rueckert; Paul Aljabar; Rolf A Heckemann; Joseph V Hajnal; Alexander Hammers
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

10.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

Authors:  F Lamare; M J Ledesma Carbayo; T Cresson; G Kontaxakis; A Santos; C Cheze Le Rest; A J Reader; D Visvikis
Journal:  Phys Med Biol       Date:  2007-08-09       Impact factor: 3.609

View more
  26 in total

1.  Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  MRI-based nonrigid motion correction in simultaneous PET/MRI.

Authors:  Se Young Chun; Timothy G Reese; Jinsong Ouyang; Bastien Guerin; Ciprian Catana; Xuping Zhu; Nathaniel M Alpert; Georges El Fakhri
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

3.  Motion-compensated reconstruction of magnetic resonance images from undersampled data.

Authors:  Daniel S Weller; Luonan Wang; John P Mugler; Craig H Meyer
Journal:  Magn Reson Imaging       Date:  2018-09-11       Impact factor: 2.546

4.  Spatial Confidence Regions for Quantifying and Visualizing Registration Uncertainty.

Authors:  Takanori Watanabe; Clayton Scott
Journal:  Biomed Image Regist Proc       Date:  2012

5.  Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Authors:  Chuan Huang; Yoann Petibon; Jinsong Ouyang; Timothy G Reese; Mark A Ahlman; David A Bluemke; Georges El Fakhri
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

6.  Towards coronary plaque imaging using simultaneous PET-MR: a simulation study.

Authors:  Y Petibon; G El Fakhri; R Nezafat; N Johnson; T Brady; J Ouyang
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

7.  Motion correction of respiratory-gated PET images using deep learning based image registration framework.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-07-30       Impact factor: 3.609

8.  Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery.

Authors:  S Reaungamornrat; A S Wang; A Uneri; Y Otake; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-06-17       Impact factor: 3.609

9.  Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI.

Authors:  Sajan Goud Lingala; Edward DiBella; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2014-07-29       Impact factor: 10.048

10.  Bias atlases for segmentation-based PET attenuation correction using PET-CT and MR.

Authors:  Jinsong Ouyang; Se Young Chun; Yoann Petibon; Ali A Bonab; Nathaniel Alpert; Georges El Fakhri
Journal:  IEEE Trans Nucl Sci       Date:  2013-10-01       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.