Literature DB >> 23179114

Should we worry about periacetabular interference gaps in hip resurfacing?

Bruno Gomes1, Michael Olsen, Michael Donnelly, Ashesh Kumar, Emil H Schemitsch.   

Abstract

BACKGROUND: Press-fit acetabular component seating in hip resurfacing can be challenging as a strong interference fit is required. It has not been established whether reducing the acetabular underream minimizes incomplete component seating or leads to increased acetabular loosening. QUESTIONS/PURPOSES: We examined (1) the incidence and natural history of postoperative interference gaps in hip resurfacing and (2) whether reduction of the acetabular underream from 2 mm to 1 mm reduces the incidence of periacetabular interference gaps.
METHODS: Of 327 Birmingham Hip™ Resurfacings (Smith & Nephew Inc, Memphis, TN, USA) performed by a single surgeon from 2005 to 2010, we evaluated 306 hips with a minimum 1-year radiographic followup. Postoperative periacetabular interference gaps were monitored for radiographic gap resolution at latest followup. The frequency of incomplete component seating was compared between acetabula prepared with 1- and 2-mm underream techniques. Minimum followup was 1 year (mean, 2.7 years; range, 1-6 years).
RESULTS: Fifty-one percent of the postoperative radiographs demonstrated the presence of a periacetabular interference gap. At latest followup, 96% of these gaps were no longer visible. We observed a reduction in the number of interference gaps identified when acetabular preparation changed from a 2-mm underream (63%) to a 1-mm underream (39%). There were no revisions due to acetabular failure.
CONCLUSIONS: Periacetabular interference gaps were common in this series but not associated with acetabular component failure. The use of a 1-mm underream is sufficient for adequate short-term press-fit fixation of the acetabular component in Birmingham Hip™ Resurfacing arthroplasty. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2013        PMID: 23179114      PMCID: PMC3549186          DOI: 10.1007/s11999-012-2665-0

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  24 in total

1.  The initial fixation of the press-fit acetabular shell--clinical observation and experimental study.

Authors:  K Kaneko; Y Inoue; Y Yanagihara; S Uta; A Mogami; H Iwase
Journal:  Arch Orthop Trauma Surg       Date:  2000       Impact factor: 3.067

2.  Stability of press-fit acetabular cups.

Authors:  E Adler; S A Stuchin; F J Kummer
Journal:  J Arthroplasty       Date:  1992-09       Impact factor: 4.757

3.  The initial stability of uncemented acetabular components.

Authors:  M J Curtis; R H Jinnah; V D Wilson; D S Hungerford
Journal:  J Bone Joint Surg Br       Date:  1992-05

4.  Mechanical stability of porous-coated acetabular components in total hip arthroplasty.

Authors:  J B Stiehl; E MacMillan; D A Skrade
Journal:  J Arthroplasty       Date:  1991-12       Impact factor: 4.757

5.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

6.  Migration and wear of a hydroxyapatite-coated hip prosthesis. A controlled roentgen stereophotogrammetric study.

Authors:  I Onsten; A S Carlsson; L Sanzén; J Besjakov
Journal:  J Bone Joint Surg Br       Date:  1996-01

7.  Development and first experience with an uncemented press-fit cup.

Authors:  E Morscher; Z Masar
Journal:  Clin Orthop Relat Res       Date:  1988-07       Impact factor: 4.176

8.  Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty.

Authors:  J R MacKenzie; J J Callaghan; D R Pedersen; T D Brown
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

9.  Rationale of a flexible press fit cup in total hip replacement. 5-year followup in 280 procedures.

Authors:  E Morscher; B Berli; W Jockers; R Schenk
Journal:  Clin Orthop Relat Res       Date:  1997-08       Impact factor: 4.176

10.  Fracture of the acetabulum during insertion of an oversized hemispherical component.

Authors:  Y S Kim; J J Callaghan; P B Ahn; T D Brown
Journal:  J Bone Joint Surg Am       Date:  1995-01       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.