Literature DB >> 1587880

The initial stability of uncemented acetabular components.

M J Curtis1, R H Jinnah, V D Wilson, D S Hungerford.   

Abstract

The osseo-integration of an uncemented acetabular component depends on its initial stability. This is usually provided by under-reaming of the acetabulum. We have assessed the fixation of 52 mm porous-coated hemispherical prostheses inserted into cadaveric acetabula under-reamed by 1, 2, 3 and 4 mm. We tested the torsional stability of fixation, after preloading with 686 N in compression, by measuring the torque required to produce 1 degree and 2 degrees of rotation. Under-reaming by 2 mm and 3 mm gave significantly better fixation than 1 mm (p less than 0.01, p less than 0.02). Insertion after under-reaming of 4 mm caused some fractures. To obtain maximum interference fit and optimal implant stability, we recommend the use of an implant 2 mm or 3 mm larger than the last reamer.

Entities:  

Mesh:

Year:  1992        PMID: 1587880

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  29 in total

Review 1.  Treatment algorithm of acetabular periprosthetic fractures.

Authors:  Paul Simon; Philipp von Roth; Carsten Perka
Journal:  Int Orthop       Date:  2015-08-30       Impact factor: 3.075

2.  Periprosthetic acetabular fractures.

Authors:  Francesco Benazzo; Mario Formagnana; Marco Bargagliotti; Loris Perticarini
Journal:  Int Orthop       Date:  2015-08-27       Impact factor: 3.075

3.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

4.  Complications of total hip arthroplasty: periprosthetic fractures of the acetabulum.

Authors:  Amol Chitre; Henry Wynn Jones; Nikhil Shah; Anthony Clayson
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

5.  [Influence of acetabular cup design on the primary implant stability : an experimental and numerical analysis].

Authors:  C Zietz; A Fritsche; D Kluess; W Mittelmeier; R Bader
Journal:  Orthopade       Date:  2009-11       Impact factor: 1.087

6.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

7.  Uncemented porous-coated anatomic total hip replacement in Chinese patients.

Authors:  K H Chiu; W Y Shen; K M Chan
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

Review 8.  [Periprosthetic fractures after total hip arthroplasty : classification, diagnosis and therapy strategies].

Authors:  B M Holzapfel; P M Prodinger; M Hoberg; R Meffert; M Rudert; R Gradinger
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

9.  Acetabular loosening using an extended offset polyethylene liner.

Authors:  Michael J Archibeck; Tamara Cummins; Daniel W Junick; Richard E White
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

Review 10.  [Periprosthetic fractures following total hip and knee arthroplasty: Risk factors, epidemiological aspects, diagnostics and classification systems].

Authors:  M Fuchs; C Perka; P von Roth
Journal:  Unfallchirurg       Date:  2016-03       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.