Literature DB >> 7822342

Fracture of the acetabulum during insertion of an oversized hemispherical component.

Y S Kim1, J J Callaghan, P B Ahn, T D Brown.   

Abstract

A hemispherical metal-backed acetabular component that was oversized by two or four millimeters was introduced without cement into thirty fresh or embalmed cadaveric acetabula that were fifty, fifty-two, fifty-four, fifty-six, or fifty-eight millimeters in diameter. Manual tapping was used to insert the component into ten fresh and ten embalmed specimens, and a materials testing machine was used for the remaining five fresh and five embalmed specimens. The magnitude of force and the number of pulses necessary to seat the component were determined for the insertions performed with the materials testing machine; 2000 and 3000 newtons of force were required to insert the cups that were oversized by two and four millimeters, respectively. Visual and radiographic assessments were used to identify any resulting acetabular fractures. Over-all, eighteen (60 per cent) of the thirty acetabular specimens fractured. Of the eighteen fractures, only fifteen were detectable radiographically: ten on en face or lateral radiographs of the cup and five only on oblique radiographs of the cup. The remaining three fractures were apparent only after the removal of the acetabular component.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7822342     DOI: 10.2106/00004623-199501000-00013

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

Review 1.  Treatment algorithm of acetabular periprosthetic fractures.

Authors:  Paul Simon; Philipp von Roth; Carsten Perka
Journal:  Int Orthop       Date:  2015-08-30       Impact factor: 3.075

2.  Periprosthetic acetabular fractures.

Authors:  Francesco Benazzo; Mario Formagnana; Marco Bargagliotti; Loris Perticarini
Journal:  Int Orthop       Date:  2015-08-27       Impact factor: 3.075

3.  Complications of total hip arthroplasty: periprosthetic fractures of the acetabulum.

Authors:  Amol Chitre; Henry Wynn Jones; Nikhil Shah; Anthony Clayson
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

4.  [Influence of acetabular cup design on the primary implant stability : an experimental and numerical analysis].

Authors:  C Zietz; A Fritsche; D Kluess; W Mittelmeier; R Bader
Journal:  Orthopade       Date:  2009-11       Impact factor: 1.087

5.  [Impacted acetabular cups].

Authors:  A Dambreville; P Lautridou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

6.  Periprosthetic Occult Fractures of the Acetabulum Occur Frequently During Primary THA.

Authors:  Kazuhiro Hasegawa; Tamon Kabata; Yoshitomo Kajino; Daisuke Inoue; Hiroyuki Tsuchiya
Journal:  Clin Orthop Relat Res       Date:  2016-10-31       Impact factor: 4.176

7.  A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

Authors:  S G Clarke; A T M Phillips; A M J Bull; J P Cobb
Journal:  J Biomech       Date:  2012-04-16       Impact factor: 2.712

8.  Protrusio After Medial Acetabular Wall Breach in Total Hip Arthroplasty.

Authors:  Christopher T Martin; Anneliese D Heiner; Thomas E Baer; Andrew J Pugely; Nicolas O Noiseux
Journal:  Iowa Orthop J       Date:  2015

9.  Should we worry about periacetabular interference gaps in hip resurfacing?

Authors:  Bruno Gomes; Michael Olsen; Michael Donnelly; Ashesh Kumar; Emil H Schemitsch
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

10.  Objective evaluation for initial stability of highly porous cup without screws in total hip arthroplasty for femoral neck fracture.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Hiroki Tanabe; Taiji Watari; Hironori Ochi; Sammy Banno; Tomonori Baba; Kazuo Kaneko
Journal:  J Orthop       Date:  2019-08-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.