Literature DB >> 1402946

Stability of press-fit acetabular cups.

E Adler1, S A Stuchin, F J Kummer.   

Abstract

Mechanical tests were performed to characterize the initial stability of press-fit cups as a function of cup design, surface structure, and surgical preparation. Eight cups from six manufacturers were press-fit into acetabular cavities prepared in two densities of Sawbones polyethylene foam and in bovine knee trabecular bone. Cavity sizes and cup loading forces were varied. Acetabular defects were simulated in the Sawbones model. Preparations were tested to determine axial-rotatory and tangential ("levering-out") stability. Results suggested that cup geometry and proper surgical technique--in particular, proper sizing and depth of the acetabular cavity--are important in determining initial cup stability independent of adjuvant screw or spike fixation. Stability is a function of the area of interface contact between the cup rim and the substrate. If the cavity is too small or too shallow, and the substrate too dense, the cup will not seat to the rim and stability will be compromised. If there are defects in the rim, the area of interface contact will be diminished and stability compromised. Cups with a true hemispherical design have a greater area of rim interface contact than "low-profile" cups and are therefore more stable. 1 mm undersizing of the cavity (or 2 mm undersizing in less dense substrate) appears to provide optimal stability.

Entities:  

Mesh:

Year:  1992        PMID: 1402946     DOI: 10.1016/0883-5403(92)90052-r

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  22 in total

1.  [Periprosthetic bone loss after total hip endoprosthesis. Dependence on the type of prosthesis and preoperative bone configuration].

Authors:  A Roth; G Richartz; K Sander; A Sachse; R Fuhrmann; A Wagner; R-A Venbrocks
Journal:  Orthopade       Date:  2005-04       Impact factor: 1.087

2.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

3.  [Influence of acetabular cup design on the primary implant stability : an experimental and numerical analysis].

Authors:  C Zietz; A Fritsche; D Kluess; W Mittelmeier; R Bader
Journal:  Orthopade       Date:  2009-11       Impact factor: 1.087

4.  [Impacted acetabular cups].

Authors:  A Dambreville; P Lautridou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

5.  Finite element model of the impaction of a press-fitted acetabular cup.

Authors:  Adrien Michel; Vu-Hieu Nguyen; Romain Bosc; Romain Vayron; Philippe Hernigou; Salah Naili; Guillaume Haiat
Journal:  Med Biol Eng Comput       Date:  2016-08-04       Impact factor: 2.602

6.  Validation of FE micromotions and strains around a press-fit cup: introducing a new micromotion measuring technique.

Authors:  S G Clarke; A T M Phillips; A M J Bull
Journal:  Ann Biomed Eng       Date:  2012-02-16       Impact factor: 3.934

7.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

8.  Should we worry about periacetabular interference gaps in hip resurfacing?

Authors:  Bruno Gomes; Michael Olsen; Michael Donnelly; Ashesh Kumar; Emil H Schemitsch
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

9.  Objective evaluation for initial stability of highly porous cup without screws in total hip arthroplasty for femoral neck fracture.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Hiroki Tanabe; Taiji Watari; Hironori Ochi; Sammy Banno; Tomonori Baba; Kazuo Kaneko
Journal:  J Orthop       Date:  2019-08-10

10.  Primary stability of two uncementedacetabular components of different geometry: hemispherical or peripherallyenhanced?

Authors:  G Antoniades; E J Smith; A H Deakin; S C Wearing; M Sarungi
Journal:  Bone Joint Res       Date:  2013-12-10       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.