Literature DB >> 8898134

Migration and wear of a hydroxyapatite-coated hip prosthesis. A controlled roentgen stereophotogrammetric study.

I Onsten1, A S Carlsson, L Sanzén, J Besjakov.   

Abstract

A consecutive series of 30 total hip replacements using a hydroxyapatite (HA)-coated, modular implant (Omnifit) was followed clinically and by roentgen stereophotogrammetric analysis for two years and compared with two control groups, one of 27 cemented Charnley sockets and one of 40 cemented Charnley stems. Omnifit sockets with a central gap between the dome of the socket and the acetabular bone in the postoperative radiographs, migrated less than sockets without such gaps (p = 0.01). After adjustment for patient-related factors (age, gender and weight), no significant difference was found between the two prostheses with respect to micromotion and wear. We conclude that the early fixation of the HA-coated Omnifit prosthesis compares with that of the cemented Charnley prosthesis.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8898134

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

1.  Full weight bearing after non-cemented total hip replacement is compatible with satisfactory results.

Authors:  Y K Chan; K Y Chiu; D K H Yip; T P Ng; W M Tang
Journal:  Int Orthop       Date:  2003-01-11       Impact factor: 3.075

2.  Should we worry about periacetabular interference gaps in hip resurfacing?

Authors:  Bruno Gomes; Michael Olsen; Michael Donnelly; Ashesh Kumar; Emil H Schemitsch
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

3.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  Similar outcome with a new anteverted or a straight standard stem: a randomized study of 72 total hip arthroplasties evaluated with clinical variables, radiostereometry, and DXA up to 2 years.

Authors:  Karin Rilby; Maziar Mohaddes; Emma Nauclér; Johan Kärrholm
Journal:  Acta Orthop       Date:  2022-01-03       Impact factor: 3.717

5.  A cementless, elastic press-fit socket with and without screws.

Authors:  Dean Pakvis; Joan Luites; Gijs van Hellemondt; Maarten Spruit
Journal:  Acta Orthop       Date:  2012-10       Impact factor: 3.717

Review 6.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

7.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

8.  Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

Authors:  Sami Finnilä; Niko Moritz; Erkki SvedströM; Jessica J Alm; Hannu T Aro
Journal:  Acta Orthop       Date:  2015-11-16       Impact factor: 3.717

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.