Literature DB >> 3383507

Development and first experience with an uncemented press-fit cup.

E Morscher1, Z Masar.   

Abstract

A new cup with a new concept of cementless fixation and new coating was designed to obtain primary stability by a press-fit mechanism. The press-fit mechanism is achieved by flattening the dome of the hemispheric cup and by using a cup size with an outer diameter 1.5 mm larger than the reamer used last. The coating (Sulmesh) consists of a net shell of four layers of orderly oriented wire meshes with specific pore size and porosity volume. The pure titanium wires are bonded together. The advantages of the press-fit cup are the excellent adaptation with minimal resection and the preservation of the subchondral bone. The preparation of the acetabulum is easy (reaming only), no additional fixation by screws is necessary, and only a few instruments are needed. The results of 81 total hip arthoplasties using the press-fit cup and having an observation period ranging from 12 to 24 months show no clinical or roentgenographic loosening. No intraoperative or postoperative complications because of the press-fit cup were seen.

Entities:  

Mesh:

Year:  1988        PMID: 3383507

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  [Principles of fixation of the cementless modular revision stem Revitan].

Authors:  B Fink; M Fuerst; M Hahn; L Thybaud; H-P Sieber; G Delling
Journal:  Unfallchirurg       Date:  2005-12       Impact factor: 1.000

2.  Metropolitan and micropolitan statistical area estimates of depression and anxiety using the Patient Health Questionnaire-8 in the 2006 Behavioral Risk Factor Surveillance System.

Authors:  Tara W Strine; Satvinder S Dhingra; Kurt Kroenke; Mohamed Qayad; James L Ribble; Catherine A Okoro; Lina S Balluz; Shanta R Dube; James Lando; Ali H Mokdad
Journal:  Int J Public Health       Date:  2009       Impact factor: 3.380

3.  [Reconstruction of large acetabular defects using trabecular metal augments].

Authors:  Olaf Hasart; Carsten Perka; Rex Lehnigk; Stephan Tohtz
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

4.  Total hip replacement with solid autologous femoral head graft for hip dysplasia.

Authors:  B Hintermann; E W Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

5.  [Long-term results of 2 uncemented acetabular cup components in total hip prosthesis].

Authors:  D Schmitt; O Bigard; F Bresler; D Molé; P Bernard
Journal:  Int Orthop       Date:  1993-12       Impact factor: 3.075

6.  [Acetabulum without cement. Short-term results of a series of 112 threaded cups].

Authors:  F Gouin; F Fechoz; N Passuti; J Sentucq-Rigal; O Bertrand; J V Bainvel
Journal:  Int Orthop       Date:  1993       Impact factor: 3.075

7.  Should we worry about periacetabular interference gaps in hip resurfacing?

Authors:  Bruno Gomes; Michael Olsen; Michael Donnelly; Ashesh Kumar; Emil H Schemitsch
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

8.  Survival of uncemented acetabular monoblock cups: evaluation of 210 hips in the Swedish Hip Arthroplasty Register.

Authors:  Rüdiger J Weiss; Nils P Hailer; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-05-10       Impact factor: 3.717

9.  Primary stability of two uncementedacetabular components of different geometry: hemispherical or peripherallyenhanced?

Authors:  G Antoniades; E J Smith; A H Deakin; S C Wearing; M Sarungi
Journal:  Bone Joint Res       Date:  2013-12-10       Impact factor: 5.853

10.  Impaction technique influences implant stability in low-density bone model.

Authors:  Ruben Doyle; Richard J van Arkel; Sarah Muirhead-Allwood; Jonathan R T Jeffers
Journal:  Bone Joint Res       Date:  2020-07-31       Impact factor: 5.853

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.