Literature DB >> 23143179

Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Stephan Meckel1, Lorenz Leitner, Leo H Bonati, Francesco Santini, Tilman Schubert, Aurelien F Stalder, Philippe Lyrer, Michael Markl, Stephan G Wetzel.   

Abstract

INTRODUCTION: 4D phase contrast MR imaging (4D PC MRI) has been introduced for spatiotemporal evaluation of intracranial hemodynamics in various cerebrovascular diseases. However, it still lacks validation with standards of reference. Our goal was to compare blood flow quantification derived from 4D PC MRI with transcranial ultrasound and 2D PC MRI.
METHODS: Velocity measurements within large intracranial arteries [internal carotid artery (ICA), basilar artery (BA), and middle cerebral artery (MCA)] were obtained in 20 young healthy volunteers with 4D and 2D PC MRI, transcranial Doppler sonography (TCD), and transcranial color-coded duplex sonography (TCCD). Maximum velocities at peak systole (PSV) and end diastole (EDV) were compared using regression analysis and Bland-Altman plots.
RESULTS: Correlation of 4D PC MRI measured velocities was higher in comparison with TCD (r = 0.49-0.66) than with TCCD (0.35-0.44) and 2D PC MRI (0.52-0.60). In mid-BA and ICA C7 segment, a significant correlation was found with TCD (0.68-0.81 and 0.65-0.71, respectively). No significant correlation was found in carotid siphon. On average over all volunteers, PSVs and EDVs in MCA were minimally underestimated compared with TCD/TCCD. Minimal overestimation of velocities was found compared to TCD in mid-BA and ICA C7 segment.
CONCLUSION: 4D PC MRI appears as valid alternative for intracranial velocity measurement consistent with previous reference standards, foremost with TCD. Spatiotemporal averaging effects might contribute to vessel size-dependent mild underestimation of velocities in smaller (MCA), and overestimation in larger-sized (BA and ICA) arteries, respectively. Complete spatiotemporal flow analysis may be advantageous in anatomically complex regions (e.g. carotid siphon) relative to restrictions of ultrasound techniques.

Entities:  

Mesh:

Year:  2012        PMID: 23143179     DOI: 10.1007/s00234-012-1103-z

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  39 in total

1.  Phase contrast MRI with improved temporal resolution by view sharing: k-space related velocity mapping properties.

Authors:  M Markl; J Hennig
Journal:  Magn Reson Imaging       Date:  2001-06       Impact factor: 2.546

2.  Visualization of hemodynamics in intracranial arteries using time-resolved three-dimensional phase-contrast MRI.

Authors:  Shuhei Yamashita; Haruo Isoda; Masaya Hirano; Hiroyasu Takeda; Shoichi Inagawa; Yasuo Takehara; Marcus T Alley; Michael Markl; Norbert J Pelc; Harumi Sakahara
Journal:  J Magn Reson Imaging       Date:  2007-03       Impact factor: 4.813

3.  In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

Authors:  S Wetzel; S Meckel; A Frydrychowicz; L Bonati; E-W Radue; K Scheffler; J Hennig; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

4.  Quantification and visualization of flow in the Circle of Willis: time-resolved three-dimensional phase contrast MRI at 7 T compared with 3 T.

Authors:  P van Ooij; J J M Zwanenburg; F Visser; C B Majoie; E vanBavel; J Hendrikse; A J Nederveen
Journal:  Magn Reson Med       Date:  2012-05-22       Impact factor: 4.668

5.  Side-to-side differences and day-to-day variations of transcranial Doppler parameters in normal subjects.

Authors:  W Sorteberg; I A Langmoen; K F Lindegaard; H Nornes
Journal:  J Ultrasound Med       Date:  1990-07       Impact factor: 2.153

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Color Doppler imaging of basal cerebral arteries: normal reference values and clinical applications.

Authors:  E Bartels; H H Fuchs; K A Flügel
Journal:  Angiology       Date:  1995-10       Impact factor: 3.619

8.  A comparative study of velocity measurements in major blood vessels using magnetic resonance imaging and Doppler ultrasound.

Authors:  F V Zananiri; P C Jackson; M Halliwell; R A Harris; J K Hayward; E R Davies; P N Wells
Journal:  Br J Radiol       Date:  1993-12       Impact factor: 3.039

9.  Transcranial color Doppler sonography of basal cerebral arteries in 182 healthy subjects: age and sex variability and normal reference values for blood flow parameters.

Authors:  J Krejza; Z Mariak; J Walecki; P Szydlik; J Lewko; A Ustymowicz
Journal:  AJR Am J Roentgenol       Date:  1999-01       Impact factor: 3.959

10.  Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients.

Authors:  Michael Markl; Mary T Draney; Michael D Hope; Jonathan M Levin; Frandics P Chan; Marcus T Alley; Norbert J Pelc; Robert J Herfkens
Journal:  J Comput Assist Tomogr       Date:  2004 Jul-Aug       Impact factor: 1.826

View more
  29 in total

Review 1.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

2.  Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging.

Authors:  Maria Correia de Verdier; Johan Wikström
Journal:  Neuroradiology       Date:  2016-02-16       Impact factor: 2.804

3.  In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV.

Authors:  Rafael Medero; Katrina Ruedinger; David Rutkowski; Kevin Johnson; Alejandro Roldán-Alzate
Journal:  Ann Biomed Eng       Date:  2020-06-10       Impact factor: 3.934

4.  Blood flow distribution in cerebral arteries.

Authors:  Laleh Zarrinkoob; Khalid Ambarki; Anders Wåhlin; Richard Birgander; Anders Eklund; Jan Malm
Journal:  J Cereb Blood Flow Metab       Date:  2015-03-31       Impact factor: 6.200

Review 5.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

6.  Velocity-selective magnetization-prepared non-contrast-enhanced cerebral MR angiography at 3 Tesla: Improved immunity to B0/B1 inhomogeneity.

Authors:  Qin Qin; Taehoon Shin; Michael Schär; Hua Guo; Hanwei Chen; Ye Qiao
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

7.  Measurement of cerebral blood flow using phase contrast magnetic resonance imaging and duplex ultrasonography.

Authors:  Muhammad Ayaz Khan; Jie Liu; Takashi Tarumi; Justin Stevan Lawley; Peiying Liu; David C Zhu; Hanzhang Lu; Rong Zhang
Journal:  J Cereb Blood Flow Metab       Date:  2016-07-20       Impact factor: 6.200

8.  Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI.

Authors:  Michael J Rose; Kelly Jarvis; Varun Chowdhary; Alex J Barker; Bradley D Allen; Joshua D Robinson; Michael Markl; Cynthia K Rigsby; Susanne Schnell
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

Review 9.  Advanced flow MRI: emerging techniques and applications.

Authors:  M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby
Journal:  Clin Radiol       Date:  2016-03-02       Impact factor: 2.350

10.  4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

Authors:  Tetsuro Sekine; Ryo Takagi; Yasuo Amano; Yasuo Murai; Erika Orita; Yoshio Matsumura; Shin-Ichiro Kumita
Journal:  Neuroradiology       Date:  2015-12-02       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.