Literature DB >> 11672625

Phase contrast MRI with improved temporal resolution by view sharing: k-space related velocity mapping properties.

M Markl1, J Hennig.   

Abstract

Phase contrast techniques in combination with k-space segmented CINE imaging are widely used for the quantitative assessment of blood flow or tissue motion. The temporal resolution of the corresponding pulse sequences plays an important role concerning the potential of the method to fully detect time resolved flow or motion patterns. A further improvement of temporal or spatial resolution in phase contrast CINE MRI can be achieved by the application of view sharing. Based on simulations with point-spread-functions resulting from different cyclic flow or motion patterns an analysis of view sharing techniques in combination with phase contrast MRI is presented. Velocity mapping properties and the role of different k-space regions concerning the resulting values in the phase images and thus encoded velocities were investigated. It could be shown that the velocity induced phase shifts in phase contrast techniques are mainly encoded in the central sections of k-space which makes view sharing also suitable for velocity mapping. As a result the use of appropriate sampling and data acquisition schemes permits the assessment of flow or motion patterns with significantly improved temporal resolution without loss of functional information. In addition phantom measurements with an oscillation phantom were performed in order to validate the simulation results and to demonstrate the potential of view sharing techniques to accelerate phase contrast imaging and improve the detection of the underlying flow or motion dynamics.

Entities:  

Mesh:

Year:  2001        PMID: 11672625     DOI: 10.1016/s0730-725x(01)00386-1

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  21 in total

1.  In vivo assessment and visualization of intracranial arterial hemodynamics with flow-sensitized 4D MR imaging at 3T.

Authors:  S Wetzel; S Meckel; A Frydrychowicz; L Bonati; E-W Radue; K Scheffler; J Hennig; M Markl
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

2.  Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography.

Authors:  Christophe Meyer; Laurent Bonnemains; François Marçon; Pierre-Yves Marie; Jacques Felblinger; Pierre-André Vuissoz
Journal:  MAGMA       Date:  2013-09-08       Impact factor: 2.310

3.  SAR reduced black-blood cine TPM for increased temporal resolution at 3T.

Authors:  Anja Lutz; Axel Bornstedt; Robert Manzke; G Ulrich Nienhaus; Patrick Etyngier; Volker Rasche
Journal:  MAGMA       Date:  2011-01-19       Impact factor: 2.310

4.  Simulation study of the effect of golden-angle KWIC with generalized kinetic model analysis on diagnostic accuracy for lesion discrimination.

Authors:  Melanie Freed; Sungheon G Kim
Journal:  Magn Reson Imaging       Date:  2014-09-28       Impact factor: 2.546

5.  Intracranial artery velocity measurement using 4D PC MRI at 3 T: comparison with transcranial ultrasound techniques and 2D PC MRI.

Authors:  Stephan Meckel; Lorenz Leitner; Leo H Bonati; Francesco Santini; Tilman Schubert; Aurelien F Stalder; Philippe Lyrer; Michael Markl; Stephan G Wetzel
Journal:  Neuroradiology       Date:  2012-11-10       Impact factor: 2.804

6.  Combination of tagging and tissue phase mapping to accelerate myocardial motion measurements in three directions.

Authors:  Anja Lutz; Jan Paul; Axel Bornstedt; Gerd Ulrich Nienhaus; Patrick Etyngier; Peter Bernhardt; Wolfgang Rottbauer; Volker Rasche
Journal:  MAGMA       Date:  2012-08-05       Impact factor: 2.310

7.  Highly accelerated aortic 4D flow MR imaging with variable-density random undersampling.

Authors:  Jing Liu; Petter Dyverfeldt; Gabriel Acevedo-Bolton; Michael Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2014-05-17       Impact factor: 2.546

8.  Shared velocity encoding: a method to improve the temporal resolution of phase-contrast velocity measurements.

Authors:  Hung-Yu Lin; Jacob A Bender; Yu Ding; Yiu-Cho Chung; Alice M Hinton; Michael L Pennell; Kevin K Whitehead; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

9.  Flow characteristics in a canine aneurysm model: a comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations.

Authors:  Jingfeng Jiang; Kevin Johnson; Kristian Valen-Sendstad; Kent-Andre Mardal; Oliver Wieben; Charles Strother
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

10.  Reproducibility of cerebrospinal venous blood flow and vessel anatomy with the use of phase contrast-vastly undersampled isotropic projection reconstruction and contrast-enhanced MRA.

Authors:  E M Schrauben; K M Johnson; J Huston; A M Del Rio; S B Reeder; A Field; O Wieben
Journal:  AJNR Am J Neuroradiol       Date:  2013-11-28       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.