Literature DB >> 26944696

Advanced flow MRI: emerging techniques and applications.

M Markl1, S Schnell2, C Wu3, E Bollache2, K Jarvis3, A J Barker2, J D Robinson4, C K Rigsby5.   

Abstract

Magnetic resonance imaging (MRI) techniques provide non-invasive and non-ionising methods for the highly accurate anatomical depiction of the heart and vessels throughout the cardiac cycle. In addition, the intrinsic sensitivity of MRI to motion offers the unique ability to acquire spatially registered blood flow simultaneously with the morphological data, within a single measurement. In clinical routine, flow MRI is typically accomplished using methods that resolve two spatial dimensions in individual planes and encode the time-resolved velocity in one principal direction, typically oriented perpendicular to the two-dimensional (2D) section. This review describes recently developed advanced MRI flow techniques, which allow for more comprehensive evaluation of blood flow characteristics, such as real-time flow imaging, 2D multiple-venc phase contrast MRI, four-dimensional (4D) flow MRI, quantification of complex haemodynamic properties, and highly accelerated flow imaging. Emerging techniques and novel applications are explored. In addition, applications of these new techniques for the improved evaluation of cardiovascular (aorta, pulmonary arteries, congenital heart disease, atrial fibrillation, coronary arteries) as well as cerebrovascular disease (intra-cranial arteries and veins) are presented.
Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26944696      PMCID: PMC4930408          DOI: 10.1016/j.crad.2016.01.011

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  228 in total

1.  Heart motion adapted cine phase-contrast flow measurements through the aortic valve.

Authors:  S Kozerke; M B Scheidegger; E M Pedersen; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Computational fluid dynamics modeling of intracranial aneurysms: effects of parent artery segmentation on intra-aneurysmal hemodynamics.

Authors:  M A Castro; C M Putman; J R Cebral
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

3.  Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulation.

Authors:  Michael Markl; Julia Geiger; Philip J Kilner; Daniela Föll; Brigitte Stiller; Friedhelm Beyersdorf; Raoul Arnold; Alex Frydrychowicz
Journal:  Eur J Cardiothorac Surg       Date:  2010-07-02       Impact factor: 4.191

4.  Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging.

Authors:  Kate Hanneman; Milani Sivagnanam; Elsie T Nguyen; Rachel Wald; Andreas Greiser; Andrew M Crean; Sebastian Ley; Bernd J Wintersperger
Journal:  Acad Radiol       Date:  2014-08       Impact factor: 3.173

5.  Rheological changes after stenting of a cerebral aneurysm: a finite element modeling approach.

Authors:  Makoto Ohta; Stephan G Wetzel; Philippe Dantan; Caroline Bachelet; Karl O Lovblad; Hasan Yilmaz; Patrice Flaud; Daniel A Rüfenacht
Journal:  Cardiovasc Intervent Radiol       Date:  2005 Nov-Dec       Impact factor: 2.740

6.  The congenitally bicuspid aortic valve. A study of 85 autopsy cases.

Authors:  W C Roberts
Journal:  Am J Cardiol       Date:  1970-07       Impact factor: 2.778

7.  Three-dimensional hemodynamics in intracranial aneurysms: influence of size and morphology.

Authors:  Susanne Schnell; Sameer A Ansari; Parmede Vakil; Marie Wasielewski; Maria L Carr; Michael C Hurley; Bernard R Bendok; Hunt Batjer; Timothy J Carroll; James Carr; Michael Markl
Journal:  J Magn Reson Imaging       Date:  2013-10-22       Impact factor: 4.813

8.  Semi-automatic quantification of 4D left ventricular blood flow.

Authors:  Jonatan Eriksson; Carl Johan Carlhäll; Petter Dyverfeldt; Jan Engvall; Ann F Bolger; Tino Ebbers
Journal:  J Cardiovasc Magn Reson       Date:  2010-02-12       Impact factor: 5.364

9.  Assessment of intracranial venous hemodynamics in normal individuals and patients with cerebral venous thrombosis.

Authors:  E Stolz; M Kaps; W Dorndorf
Journal:  Stroke       Date:  1999-01       Impact factor: 7.914

10.  Analysis of temperature dependence of background phase errors in phase-contrast cardiovascular magnetic resonance.

Authors:  Julia Busch; S Johanna Vannesjo; Christoph Barmet; Klaas P Pruessmann; Sebastian Kozerke
Journal:  J Cardiovasc Magn Reson       Date:  2014-12-11       Impact factor: 5.364

View more
  25 in total

Review 1.  Pediatric brain MRI, Part 2: Advanced techniques.

Authors:  Mai-Lan Ho; Norbert G Campeau; Thang D Ngo; Unni K Udayasankar; Kirk M Welker
Journal:  Pediatr Radiol       Date:  2017-04-13

2.  Magnetic Resonance Imaging of Shear Stress and Wall Thickness in Tissue-Engineered Vascular Grafts.

Authors:  Mitchel R Stacy; Cameron A Best; Mark W Maxfield; Maolin Qiu; Yuji Naito; Hirotsugu Kurobe; Nathan Mahler; Kevin A Rocco; Albert J Sinusas; Toshiharu Shinoka; Smita Sampath; Christopher K Breuer
Journal:  Tissue Eng Part C Methods       Date:  2018-07-31       Impact factor: 3.056

3.  Aortic valve-mediated wall shear stress is heterogeneous and predicts regional aortic elastic fiber thinning in bicuspid aortic valve-associated aortopathy.

Authors:  Emilie Bollache; David G Guzzardi; Samaneh Sattari; Katherine E Olsen; Elena S Di Martino; S Chris Malaisrie; Pim van Ooij; Jeremy Collins; James Carr; Patrick M McCarthy; Michael Markl; Alex J Barker; Paul W M Fedak
Journal:  J Thorac Cardiovasc Surg       Date:  2018-06-12       Impact factor: 5.209

4.  Comprehensive MR Analysis of Cardiac Function, Aortic Hemodynamics and Left Ventricular Strain in Pediatric Cohort with Isolated Bicuspid Aortic Valve.

Authors:  Heather A Stefek; Haben Berhane; Joshua D Robinson; Brian Reilly; Alexander Ruh; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Cardiol       Date:  2019-07-24       Impact factor: 1.655

5.  Improved acceleration of phase-contrast flow imaging with magnitude difference regularization.

Authors:  Taehoon Shin; Wanyong Shin
Journal:  Magn Reson Imaging       Date:  2019-12-02       Impact factor: 2.546

6.  Comparison of hemodialysis arteriovenous fistula blood flow rates measured by Doppler ultrasound and phase-contrast magnetic resonance imaging.

Authors:  Yong He; Yan-Ting Shiu; Daniel B Pike; Prabir Roy-Chaudhury; Alfred K Cheung; Scott A Berceli
Journal:  J Vasc Surg       Date:  2018-05-18       Impact factor: 4.268

7.  Real-Time Transthoracic Vector Flow Imaging of the Heart in Pediatric Patients.

Authors:  R Thomas Collins; Megan E Laughlin; Sean M Lang; Elijah H Bolin; Joshua A Daily; Hanna A Jensen; Morten O Jensen
Journal:  Prog Pediatr Cardiol       Date:  2019-03-05

8.  4D flow characterization of aortic blood flow after valve sparing root reimplantation procedure.

Authors:  Nicola Galea; Filippo Piatti; Christopher Lau; Francesco Sturla; Luca Weltert; Iacopo Carbone; Ruggero De Paulis; Mario Gaudino; Leonard N Girardi
Journal:  J Vis Surg       Date:  2018-05-09

9.  Hemodynamic analysis of carotid artery after endarterectomy: a preliminary and quantitative imaging study based on computational fluid dynamics and magnetic resonance angiography.

Authors:  Yuanyuan Dai; Peng Lv; Ashkan Javadzadegan; Xiao Tang; Yi Qian; Jiang Lin
Journal:  Quant Imaging Med Surg       Date:  2018-05

Review 10.  Functional assessment of thoracic aortic aneurysms - the future of risk prediction?

Authors:  Pouya Youssefi; Rajan Sharma; C Alberto Figueroa; Marjan Jahangiri
Journal:  Br Med Bull       Date:  2017-01-01       Impact factor: 4.291

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.