Literature DB >> 23076495

Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Gianluca Plotino1, Luca Testarelli, Dina Al-Sudani, Gianlcarlo Pongione, Nicola M Grande, Gianluca Gambarini.   

Abstract

The aim of this study was to investigate whether cyclic fatigue resistance is increased for Controlled Memory (CM) Nickel-Titanium (NiTi) instruments, compared to instruments produced using traditional NiTi and instruments produced using M-Wire alloy. Two groups of NiTi endodontic instruments consisting of identical instrument sizes (constant 0.06 taper and 0.25 tip diameter and constant 0.04 taper and 0.40 tip diameter) were tested: group A compared Hyflex™ CM, Vortex ™ and ProFile ™ size 25 and 0.06 taper and group B compared Hyflex™ CM, Vortex™ and ProFile™ size 40 and 0.04 taper. 10 files from each different subgroup were tested for cyclic fatigue resistance. Mean and standard deviations of the Number of Cycles to Failure (NCF) were calculated for each group and data were statistically analysed (p < 0.05). Hyflex™ CM instruments, size 25 and 0.06 taper, and size 40 and 0.04 taper, showed a significant increase in the mean number of cycles to failure when compared with size 25 and 0.06 taper Vortex™ and ProFile™. No statistically significant difference (p > 0.05) was noted between Vortex™ and ProFile™ in the tested sizes. The new manufacturing process involving memory shape heat treatment produced new NiTi rotary files (Hyflex™ CM) significantly more resistant to fatigue than instruments produced with other proprietary methods of treatment (Vortex™) and with the traditional NiTi grinding process (ProFile™).

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23076495     DOI: 10.1007/s10266-012-0088-8

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  28 in total

Review 1.  An overview of nickel-titanium alloys used in dentistry.

Authors:  S A Thompson
Journal:  Int Endod J       Date:  2000-07       Impact factor: 5.264

2.  Factors influencing defects of rotary nickel-titanium endodontic instruments after clinical use.

Authors:  Peter Parashos; Ian Gordon; Harold H Messer
Journal:  J Endod       Date:  2004-10       Impact factor: 4.171

3.  Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique.

Authors:  G Gambarini; G Plotino; N M Grande; D Al-Sudani; M De Luca; L Testarelli
Journal:  Int Endod J       Date:  2011-01-10       Impact factor: 5.264

4.  A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments.

Authors:  G Plotino; N M Grande; E Sorci; V A Malagnino; F Somma
Journal:  Int Endod J       Date:  2006-09       Impact factor: 5.264

5.  Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?

Authors:  Gary S P Cheung; Ya Shen; Brian W Darvell
Journal:  J Endod       Date:  2007-08-23       Impact factor: 4.171

6.  Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency.

Authors:  Tung B Bui; John C Mitchell; J Craig Baumgartner
Journal:  J Endod       Date:  2008-02       Impact factor: 4.171

7.  Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

Authors:  Gianluca Gambarini; Nicola Maria Grande; Gianluca Plotino; Francesco Somma; Manish Garala; Massimo De Luca; Luca Testarelli
Journal:  J Endod       Date:  2008-06-25       Impact factor: 4.171

8.  Influence of size and taper of artificial canals on the trajectory of NiTi rotary instruments in cyclic fatigue studies.

Authors:  Gianluca Plotino; Nicola M Grande; Ciro Mazza; Renata Petrovic; Luca Testarelli; Gianluca Gambarini
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-11-17

9.  Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

Authors:  Luca Testarelli; Gianluca Plotino; Dina Al-Sudani; Valentina Vincenzi; Alessio Giansiracusa; Nicola M Grande; Gianluca Gambarini
Journal:  J Endod       Date:  2011-07-16       Impact factor: 4.171

10.  Cyclic fatigue analysis of a new generation of nickel titanium rotary instruments.

Authors:  C Michael Larsen; Ikuya Watanabe; Gerald N Glickman; Jianing He
Journal:  J Endod       Date:  2009-03       Impact factor: 4.171

View more
  21 in total

1.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

2.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

3.  Comparative analysis of canal transportation and centring ability of three Ni-Ti rotary endodontic systems: Protaper®, MTwo® and Revo-S™, assessed by micro-computed tomography.

Authors:  Karen Vallaeys; Valérie Chevalier; Reza Arbab-Chirani
Journal:  Odontology       Date:  2014-09-24       Impact factor: 2.634

4.  Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

Authors:  Amr Elnaghy; Shaymaa Elsaka
Journal:  Clin Oral Investig       Date:  2017-10-13       Impact factor: 3.573

5.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

Review 6.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

7.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01

8.  In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments.

Authors:  Gabriele Miccoli; Gianfranco Gaimari; Marco Seracchiani; Antonio Morese; Tatyana Khrenova; Dario Di Nardo
Journal:  Ann Stomatol (Roma)       Date:  2017-11-08

9.  Cutting efficiency of instruments with different movements: a comparative study.

Authors:  Luigi Tocci; Gianluca Plotino; Dina Al-Sudani; Alessio Giansiracusa Rubini; Gianpaolo Sannino; Lucila Piasecki; Ermanno Putortì; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2015-03-30

10.  Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study.

Authors:  Galvin Sim Siang Lin; Kiran Prabhakar Singbal; Tahir Yusuf Noorani; Raghavendra Penukonda
Journal:  Odontology       Date:  2021-07-16       Impact factor: 2.634

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.