Literature DB >> 16916361

A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments.

G Plotino1, N M Grande, E Sorci, V A Malagnino, F Somma.   

Abstract

AIM: To evaluate the cyclic fatigue of Mtwo Ni-Ti rotary instruments after controlled clinical use in molar teeth.
METHODOLOGY: Twenty Mtwo instruments of each size were selected and divided into two groups: group A consisted of 10 new instruments (control group); group B consisted of 10 used instruments. Each instrument in group B was used to clean and shape 10 root canals of molar teeth in patients. Cyclic fatigue testing of instruments was performed in tapered artificial canals with a 5-mm radius of curvature and a 60 degrees angle of curvature. In all 140, instruments were rotated until fracture and the number of cycles to failure was recorded. Data were analysed using one-way anova, Tukey's HSD test and independent sample t-test to determine any statistical difference; the significance was determined at the 95% confidence level.
RESULTS: A reduction of cycles to failure between new (group A) and used (group B) instruments was apparent. A statistically significant difference (P < 0.05) was noted between instruments of groups A and B in all sizes with the exception of size 40, 0.04 taper.
CONCLUSIONS: Clinical use significantly reduced cyclic fatigue resistance of Mtwo rotary instruments when compared with an unused control group. However, all the instruments had minimal instrument fatigue when discarded after controlled clinical use.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16916361     DOI: 10.1111/j.1365-2591.2006.01142.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  15 in total

1.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

2.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

3.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

4.  Cyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators--an in vivo and in vitro study.

Authors:  Gianluca Plotino; Dina Al-Sudani; Stefano Pulino; Nicola M Grande; Piero Alessandro Marcoli; Silvia Pizzi; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2012-06

5.  A comparative evaluation on the cleaning and shaping ability of three nickel titanium rotary instruments using computerized tomography - An ex vivo study.

Authors:  Gopal S Narayan; Sokkalingam Mothilal Venkatesan; C S Karumaran; Rajamani Indira; S Ramachandran; M R Srinivasan
Journal:  Contemp Clin Dent       Date:  2012-09

6.  The Effect of Size and Taper of Apical Preparation in Reducing Intra-Canal Bacteria: A Quantitative SEM Study.

Authors:  Nahid Mohammadzadeh Akhlaghi; Nahid Rahimifard; Amirabbas Moshari; Mehdi Vatanpour; Soheila Darmiani
Journal:  Iran Endod J       Date:  2013-12-24

7.  Assessment of root canal enlargement using Mtwo and BioRace rotary files.

Authors:  Enzo Cumbo; Riccardo Russo; Giuseppe Gallina
Journal:  ScientificWorldJournal       Date:  2015-03-23

8.  [Not Available].

Authors:  L Testarelli; N M Grande; G Plotino; M Lendini; G Pongione; G De Paolis; F Rizzo; V Milana; G Gambarini
Journal:  Open Dent J       Date:  2009-04-16

9.  Influence of Different Apical Preparations on Root Canal Cleanliness in Human Molars: a SEM Study.

Authors:  Gianluca Plotino; Nicola M Grande; Luigi Tocci; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2014-07-01

10.  Mechanical behavior of deep cryogenically treated martensitic shape memory nickel-titanium rotary endodontic instruments.

Authors:  Thilla Sekar Vinothkumar; Deivanayagam Kandaswamy; Gopalakrishnan Prabhakaran; Arunachalam Rajadurai
Journal:  Eur J Dent       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.