Literature DB >> 21846552

Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

Luca Testarelli1, Gianluca Plotino, Dina Al-Sudani, Valentina Vincenzi, Alessio Giansiracusa, Nicola M Grande, Gianluca Gambarini.   

Abstract

INTRODUCTION: The aim of the present study was to evaluate the bending properties of Hyflex instruments, which exhibit a lower percent in weight of nickel (52 Ni %wt) and compare them with other commercially available nickel-titanium (NiTi) rotary instruments.
METHODS: Ten instruments with tip size 25, 0.06 taper of each of the following NiTi rotary instrumentation techniques were selected for the study: Hyflex, EndoSequence, ProFile, Hero, and Flexmasters. All instruments from each group were tested for stiffness by comparing their bending moment when they attained a 45-degree bend. Experimental procedures strictly followed testing methodology described in ISO 3630-1. All data were recorded and subjected to statistical evaluation by using analysis of variance test. Statistical significance was set at P < .05).
RESULTS: Statistical analysis of the data revealed that Hyflex files were found to be the most flexible instruments, with a significant difference (P < .05) in comparison with the other instruments. Among the other files, a significant difference has been reported for EndoSequence instruments compared with ProFile, Hero, and FlexMaster (P < .05), whereas no significant differences have been reported among those 3 files (P > .05).
CONCLUSIONS: Results of the present study have illustrated an increased flexibility of the new NiTi alloy over conventional NiTi alloy, and they highlight the potential of the new manufacturing process.
Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21846552     DOI: 10.1016/j.joen.2011.05.023

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  37 in total

1.  Influence of file motion on cyclic fatigue of new nickel titanium instruments.

Authors:  Alessio Giansiracusa Rubini; Gianpaolo Sannino; Giancarlo Pongione; Luca Testarelli; Dina Al Sudani; Jeeraphat Jantarat; Massimo De Luca; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

2.  Cyclic fatigue of instruments for endodontic glide path.

Authors:  Gianluca Gambarini; Gianluca Plotino; GianPaolo Sannino; Nicola Maria Grande; Alessio Giansiracusa; Lucila Piasecki; Ulisses Xavier da Silva Neto; Dina Al-Sudani; Luca Testarelli
Journal:  Odontology       Date:  2013-11-07       Impact factor: 2.634

3.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

4.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

5.  Flexibility and resistance to cyclic fatigue of endodontic instruments made with different nickel-titanium alloys: a comparative test.

Authors:  Giancarlo Pongione; Giorgio Pompa; Valerio Milana; Stefano Di Carlo; Alessio Giansiracusa; Emanuele Nicolini; Francesca De Angelis
Journal:  Ann Stomatol (Roma)       Date:  2012-01-14

6.  Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals.

Authors:  Taha Özyürek; Mustafa Gündoğar; Gülşah Uslu; Koray Yılmaz; Simone Staffoli; Grande Nm; Gianluca Plotino; Antonella Polimeni
Journal:  Odontology       Date:  2018-01-30       Impact factor: 2.634

7.  The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment.

Authors:  Gianluca Gambarini; Luca Testarelli; Massimo De Luca; Valerio Milana; Gianluca Plotino; Nicola Maria Grande; Alessio Giansiracusa Rubini; Dina Al Sudani; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

8.  An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.

Authors:  B Shiva Kumar; Spoorti Pattanshetty; Manju Prasad; Sunny Soni; Kirti S Pattanshetty; Shiva Prasad
Journal:  J Int Oral Health       Date:  2013-10-26

9.  In Vivo Evaluation of Operative Torque Generated by Two Nickel-Titanium Rotary Instruments during Root Canal Preparation.

Authors:  Gianluca Gambarini; Massimo Galli; Marco Seracchiani; Dario Di Nardo; Marco A Versiani; Lucila Piasecki; Luca Testarelli
Journal:  Eur J Dent       Date:  2019-12-31

10.  A comparative study of mechanical resistance of two reciprocating files.

Authors:  Dario Di Nardo; Massimo Galli; Antonio Morese; Marco Seracchiani; Valerio Ferri; Gabriele Miccoli; Gianluca Gambarini; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-03-01
View more