Literature DB >> 18634935

Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

Gianluca Gambarini1, Nicola Maria Grande, Gianluca Plotino, Francesco Somma, Manish Garala, Massimo De Luca, Luca Testarelli.   

Abstract

The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p < 0.05) in the mean number of cycles to failure when compared with size 06-25 K3 files. Size 06-20 K3 instruments showed no significant increase (p > 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18634935     DOI: 10.1016/j.joen.2008.05.007

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  65 in total

1.  Performance of NiTi endodontic instrument under different temperatures.

Authors:  Ahmed Jamleh; Yoshio Yahata; Arata Ebihara; Amre R Atmeh; Turki Bakhsh; Hideaki Suda
Journal:  Odontology       Date:  2015-08-22       Impact factor: 2.634

2.  Cyclic fatigue of instruments for endodontic glide path.

Authors:  Gianluca Gambarini; Gianluca Plotino; GianPaolo Sannino; Nicola Maria Grande; Alessio Giansiracusa; Lucila Piasecki; Ulisses Xavier da Silva Neto; Dina Al-Sudani; Luca Testarelli
Journal:  Odontology       Date:  2013-11-07       Impact factor: 2.634

3.  A Comparative SEM Investigation of Smear Layer Remaining on Dentinal Walls by Three Rotary NiTi Files with Different Cross Sectional Designs in Moderately Curved Canals.

Authors:  Gaurav Sharma; Pooja Kakkar; Asit Vats
Journal:  J Clin Diagn Res       Date:  2015-03-01

4.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

5.  Mechanism of fracture of NiTi superelastic endodontic rotary instruments.

Authors:  Javier Gil; Elisa Rupérez; Eugenio Velasco; Conrado Aparicio; José María Manero
Journal:  J Mater Sci Mater Med       Date:  2018-08-07       Impact factor: 3.896

6.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

Review 7.  Shaping the root canal system.

Authors:  M Waplington; A S McRobert
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

Review 8.  Root dentine and endodontic instrumentation: cutting edge microscopic imaging.

Authors:  Amre R Atmeh; Timothy F Watson
Journal:  Interface Focus       Date:  2016-06-06       Impact factor: 3.906

9.  Cyclic fatigue resistance of XP-endo Shaper compared with different nickel-titanium alloy instruments.

Authors:  Amr Elnaghy; Shaymaa Elsaka
Journal:  Clin Oral Investig       Date:  2017-10-13       Impact factor: 3.573

10.  An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.

Authors:  B Shiva Kumar; Spoorti Pattanshetty; Manju Prasad; Sunny Soni; Kirti S Pattanshetty; Shiva Prasad
Journal:  J Int Oral Health       Date:  2013-10-26
View more