Literature DB >> 31001392

A comparative study of mechanical resistance of two reciprocating files.

Dario Di Nardo1, Massimo Galli2, Antonio Morese3, Marco Seracchiani3, Valerio Ferri3, Gabriele Miccoli4, Gianluca Gambarini2, Luca Testarelli1.   

Abstract

BACKGROUND: To evaluate the cyclic fatigue resistance of two different Nickel-Titanium instruments, Reziflow (Komet, Brasseler GmbH & Co., Lemgo, Germany) and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland).
MATERIAL AND METHODS: Two groups of 20 different NiTi endodontic instruments of identical tip size of 0.25 mm were tested; Reziflow and Wave-One Gold primary. Cyclic fatigue testing was performed in a stainless steel simulated root canal manufactured by reproducing the instrument's size and taper. A simulated root canal with a 90 degrees angle of curvature and 5 mm radius of curvature was constructed for the instruments tested. The centre of the curvature was 5 mm from the tip of the instrument and the curved segment of the canal was approximately 5 mm in length. Both the instruments were used in the same preset program specific for the WaveOne instruments. Each instrument was rotated until fracture occurred and the time to fracture (TtF) and the length of the fractured fragment were recorded. Means and standard deviations of TtF and fragment length were calculated and data were subjected to statical analysis (P<0.05).
RESULTS: Statistically significant differences (P<0.05) were noted between Reziflow and WaveOne Gold instruments. There were no significant differences (P>0.05) in the mean length of the fractured fragments between the instruments.
CONCLUSIONS: Rezifllow instruments were associated with a significantly higher cyclic fatigue resistance than WaveOne Gold instruments. Key words:Endodontic instruments, NiTi alloy, Reciprocating motion, Cyclic Fatigue, Heat treatment.

Entities:  

Year:  2019        PMID: 31001392      PMCID: PMC6461731          DOI: 10.4317/jced.55487

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


  36 in total

1.  Morphometric analysis of shank-to-flute ratio in rotary nickel-titanium files.

Authors:  M T Biz; J A P Figueiredo
Journal:  Int Endod J       Date:  2004-06       Impact factor: 5.264

2.  Effect of pitch length on the behavior of rotary triple helix root canal instruments.

Authors:  Franck Diemer; Paul Calas
Journal:  J Endod       Date:  2004-10       Impact factor: 4.171

3.  An in vitro comparison of the rake angles between K3 and ProFile endodontic file systems.

Authors:  David Y Chow; Sheila E Stover; James K Bahcall; Andris Jaunberzins; Jeffrey M Toth
Journal:  J Endod       Date:  2005-03       Impact factor: 4.171

4.  Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.

Authors:  N M Grande; G Plotino; R Pecci; R Bedini; V A Malagnino; F Somma
Journal:  Int Endod J       Date:  2006-10       Impact factor: 5.264

Review 5.  Rotary NiTi instrument fracture and its consequences.

Authors:  Peter Parashos; Harold H Messer
Journal:  J Endod       Date:  2006-11       Impact factor: 4.171

6.  Canal preparation using only one Ni-Ti rotary instrument: preliminary observations.

Authors:  G Yared
Journal:  Int Endod J       Date:  2007-12-12       Impact factor: 5.264

7.  The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue.

Authors:  Spiros Zinelis; Myrsini Darabara; Toshiyuki Takase; Kaoru Ogane; George D Papadimitriou
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2007-04-11

8.  Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

Authors:  Gianluca Gambarini; Nicola Maria Grande; Gianluca Plotino; Francesco Somma; Manish Garala; Massimo De Luca; Luca Testarelli
Journal:  J Endod       Date:  2008-06-25       Impact factor: 4.171

9.  Nickel-titanium rotary instrument fracture: a clinical practice assessment.

Authors:  P M Di Fiore; K A Genov; E Komaroff; Y Li; L Lin
Journal:  Int Endod J       Date:  2006-09       Impact factor: 5.264

10.  Impact of torsional and bending inertia on root canal instruments.

Authors:  Y L Turpin; F Chagneau; G Cathelineau; J M Vulcain
Journal:  J Endod       Date:  2001-05       Impact factor: 4.171

View more
  4 in total

1.  Analysis of the Importance of the Motion Used in the Resistance of Different Mechanical Instrumentation Systems in Endodontics: A Comparative Study.

Authors:  Jesús Mena-Álvarez; Manuel Almanzor-López; Norberto Quispe-López; Ana De Pedro-Muñoz; Cristina Rico-Romano
Journal:  Materials (Basel)       Date:  2022-06-24       Impact factor: 3.748

2.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

3.  Comparison of Obturation Removal Efficiency from Straight Root Canals with ProTaper Gold or Reciproc Blue: A Micro-Computed Tomography Study.

Authors:  Vicente Faus-Matoses; Cristina Pasarín-Linares; Ignacio Faus-Matoses; Federico Foschi; Salvatore Sauro; Vicente J Faus-Llácer
Journal:  J Clin Med       Date:  2020-04-18       Impact factor: 4.241

4.  Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model.

Authors:  Álvaro Zubizarreta-Macho; Alberto Albaladejo Martínez; Carlos Falcão Costa; Norberto Quispe-López; Ruben Agustín-Panadero; Jesús Mena-Álvarez
Journal:  BMC Oral Health       Date:  2021-04-07       Impact factor: 2.757

  4 in total