Literature DB >> 26161246

Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Gianluca Gambarini1, Gianluca Plotino1, Lucila Piasecki2, Dina Al-Sudani3, Luca Testarelli1, Gianpaolo Sannino4.   

Abstract

AIM: To compare the effect of brushing motion on torsional and cyclic fatigue resistance of TF Adaptive instruments after clinical use.
METHODS: 20 packs of TFA small sequence (SybronEndo, Orange, CA, USA) were used for this study and divided into two groups. Each instrument prepared one resin tooth, consisting in 4 canals with a complex anatomy. In group A, no brushing motion was performed. In group B, after the green instrument reached the working length, brushing motion with circumferential filing was performed for 15 seconds in each canal (overall 1 minute). All the instruments were then subjected to cyclic fatigue test and mean values and standard deviation for time to fracture were evaluated. Data were subjected to one-way analysis of variance and Bonferroni t-test procedure with a significance set at P < 0.05.
RESULTS: No instruments were broken during preparation of root canals. Two TF Adaptive green and 5 yellow showed unwinding after intracanal clinical use. No statistically significant differences were found between green instruments of both groups (P > 0.05), while a statistically significant difference was found between the yellow instruments (P < 0.05), with group B showing an higher resistance to cyclic fatigue.
CONCLUSIONS: A prolonged passive brushing motion did not adversely affected mechanical resistance of the instrument used for this purpose. Resistance to both deformations and cyclic fatigue of the second instrument within the TFA small sequence was enhanced by the coronal flaring provided by the brushing action of the first instrument used.

Entities:  

Keywords:  brushing action; cyclic fatigue; deformations; nickel-titanium

Year:  2015        PMID: 26161246      PMCID: PMC4475905     

Source DB:  PubMed          Journal:  Ann Stomatol (Roma)        ISSN: 1824-0852


  29 in total

1.  Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use.

Authors:  D Fife; G Gambarini; L r Britto Lr
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2004-02

2.  Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.

Authors:  Gianluca Plotino; Alberto Costanzo; Nicola M Grande; Renata Petrovic; Luca Testarelli; Gianluca Gambarini
Journal:  J Endod       Date:  2011-11-21       Impact factor: 4.171

3.  Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique.

Authors:  G Gambarini; G Plotino; N M Grande; D Al-Sudani; M De Luca; L Testarelli
Journal:  Int Endod J       Date:  2011-01-10       Impact factor: 5.264

4.  Influence of a brushing working motion on the fatigue life of NiTi rotary instruments.

Authors:  G Plotino; N M Grande; E Sorci; V A Malagnino; F Somma
Journal:  Int Endod J       Date:  2007-01       Impact factor: 5.264

5.  A comparison of cyclic fatigue between used and new Mtwo Ni-Ti rotary instruments.

Authors:  G Plotino; N M Grande; E Sorci; V A Malagnino; F Somma
Journal:  Int Endod J       Date:  2006-09       Impact factor: 5.264

6.  Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods.

Authors:  Gianluca Gambarini; Nicola Maria Grande; Gianluca Plotino; Francesco Somma; Manish Garala; Massimo De Luca; Luca Testarelli
Journal:  J Endod       Date:  2008-06-25       Impact factor: 4.171

7.  Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests.

Authors:  Gianluca Plotino; Nicola M Grande; Massimo Cordaro; Luca Testarelli; Gianluca Gambarini
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-09

8.  Influence of size and taper of artificial canals on the trajectory of NiTi rotary instruments in cyclic fatigue studies.

Authors:  Gianluca Plotino; Nicola M Grande; Ciro Mazza; Renata Petrovic; Luca Testarelli; Gianluca Gambarini
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-11-17

9.  Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

Authors:  Luca Testarelli; Gianluca Plotino; Dina Al-Sudani; Valentina Vincenzi; Alessio Giansiracusa; Nicola M Grande; Gianluca Gambarini
Journal:  J Endod       Date:  2011-07-16       Impact factor: 4.171

10.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

View more
  3 in total

1.  In Vivo Evaluation of Operative Torque Generated by Two Nickel-Titanium Rotary Instruments during Root Canal Preparation.

Authors:  Gianluca Gambarini; Massimo Galli; Marco Seracchiani; Dario Di Nardo; Marco A Versiani; Lucila Piasecki; Luca Testarelli
Journal:  Eur J Dent       Date:  2019-12-31

2.  Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use.

Authors:  Gianluca Gambarini; Lucila Piasecki; Dario Di Nardo; Gabriele Miccoli; Gianni Di Giorgio; Everdan Carneiro; Dina Al-Sudani; Luca Testarelli
Journal:  J Oral Maxillofac Res       Date:  2016-12-28

3.  Role of the Flat-Designed Surface in Improving the Cyclic Fatigue Resistance of Endodontic NiTi Rotary Instruments.

Authors:  Gianluca Gambarini; Gabriele Miccoli; Marco Seracchiani; Tatyana Khrenova; Orlando Donfrancesco; Maurilio D'Angelo; Massimo Galli; Dario Di Nardo; Luca Testarelli
Journal:  Materials (Basel)       Date:  2019-08-08       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.