Literature DB >> 22978860

Cross-imaging system comparison of backscatter coefficient estimates from a tissue-mimicking material.

Kibo Nam1, Ivan M Rosado-Mendez, Lauren A Wirtzfeld, Viksit Kumar, Ernest L Madsen, Goutam Ghoshal, Alexander D Pawlicki, Michael L Oelze, Roberto J Lavarello, Timothy A Bigelow, James A Zagzebski, William D O'Brien, Timothy J Hall.   

Abstract

A key step toward implementing quantitative ultrasound techniques in a clinical setting is demonstrating that parameters such as the ultrasonic backscatter coefficient (BSC) can be accurately estimated independent of the clinical imaging system used. In previous studies, agreement in BSC estimates for well characterized phantoms was demonstrated across different laboratory systems. The goal of this study was to compare the BSC estimates of a tissue mimicking sample measured using four clinical scanners, each providing RF echo data in the 1-15 MHz frequency range. The sample was previously described and characterized with single-element transducer systems. Using a reference phantom for analysis, excellent quantitative agreement was observed across the four array-based imaging systems for BSC estimates. Additionally, the estimates from data acquired with the clinical systems agreed with theoretical predictions and with estimates from laboratory measurements using single-element transducers.

Mesh:

Substances:

Year:  2012        PMID: 22978860      PMCID: PMC3460978          DOI: 10.1121/1.4742725

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  15 in total

1.  Statistics of ultrasonic scatterer size estimation with a reference phantom.

Authors:  Anthony Gerig; James Zagzebski; Tomy Varghese
Journal:  J Acoust Soc Am       Date:  2003-06       Impact factor: 1.840

2.  Ultrasonic tissue characterization using 2-D spectrum analysis and its application in ocular tumor diagnosis.

Authors:  Tian Liu; Frederic L Lizzi; Ronald H Silverman; Gerald J Kutcher
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

3.  Parametric ultrasound imaging from backscatter coefficient measurements: image formation and interpretation.

Authors:  M F Insana; T J Hall
Journal:  Ultrason Imaging       Date:  1990-10       Impact factor: 1.578

4.  Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gels.

Authors:  Ernest L Madsen; Maritza A Hobson; Hairong Shi; Tomy Varghese; Gary R Frank
Journal:  Ultrasound Med Biol       Date:  2006-02       Impact factor: 2.998

5.  Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors.

Authors:  L X Yao; J A Zagzebski; E L Madsen
Journal:  Ultrason Imaging       Date:  1990-01       Impact factor: 1.578

6.  Renal ultrasound using parametric imaging techniques to detect changes in microstructure and function.

Authors:  M F Insana; T J Hall; J G Wood; Z Y Yan
Journal:  Invest Radiol       Date:  1993-08       Impact factor: 6.016

7.  Method of data reduction for accurate determination of acoustic backscatter coefficients.

Authors:  E L Madsen; M F Insana; J A Zagzebski
Journal:  J Acoust Soc Am       Date:  1984-09       Impact factor: 1.840

8.  Ultrasound attenuation measurements using a reference phantom with sound speed mismatch.

Authors:  Kibo Nam; Ivan M Rosado-Mendez; Nicholas C Rubert; Ernest L Madsen; James A Zagzebski; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2011-10       Impact factor: 1.578

9.  Interlaboratory comparison of backscatter coefficient estimates for tissue-mimicking phantoms.

Authors:  Janelle J Anderson; Maria-Teresa Herd; Michael R King; Alexander Haak; Zachary T Hafez; Jun Song; Michael L Oelze; Ernest L Madsen; James A Zagzebski; William D O'Brien; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2010-01       Impact factor: 1.578

10.  Envelope amplitude analysis following narrow-band filtering: a technique for ultrasonic tissue characterization.

Authors:  F G Sommer; R A Stern; P J Howes; H Young
Journal:  Med Phys       Date:  1987 Jul-Aug       Impact factor: 4.071

View more
  12 in total

Review 1.  The mechanical role of the cervix in pregnancy.

Authors:  Kristin M Myers; Helen Feltovich; Edoardo Mazza; Joy Vink; Michael Bajka; Ronald J Wapner; Timothy J Hall; Michael House
Journal:  J Biomech       Date:  2015-03-11       Impact factor: 2.712

2.  Estimation of Backscatter Coefficients Using an In Situ Calibration Source.

Authors:  Trong N Nguyen; Alex J Tam; Minh N Do; Michael L Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-27       Impact factor: 2.725

3.  Comparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners.

Authors:  Kibo Nam; Ivan M Rosado-Mendez; Lauren A Wirtzfeld; Goutam Ghoshal; Alexander D Pawlicki; Ernest L Madsen; Roberto J Lavarello; Michael L Oelze; James A Zagzebski; William D O'Brien; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2012-10       Impact factor: 1.578

4.  Characterizing Fatty Liver in vivo in Rabbits, Using Quantitative Ultrasound.

Authors:  Trong N Nguyen; Anthony S Podkowa; Alex Y Tam; Eben C Arnold; Rita J Miller; Trevor H Park; Minh N Do; Michael L Oelze
Journal:  Ultrasound Med Biol       Date:  2019-05-08       Impact factor: 2.998

5.  Quantifying Backscatter Anisotropy Using the Reference Phantom Method.

Authors:  Quinton W Guerrero; Ivan M Rosado-Mendez; Lindsey C Drehfal; Helen Feltovich; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-04-27       Impact factor: 2.725

6.  Gap-filling method for suppressing grating lobes in ultrasound imaging: Experimental study with deep-learning approach.

Authors:  Viksit Kumar; Po-Yang Lee; Bae-Hyung Kim; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Access       Date:  2020-04-21       Impact factor: 3.367

7.  Quantitative ultrasound and apoptotic death in the neonatal primate brain.

Authors:  Ivan M Rosado-Mendez; Kevin K Noguchi; Laura Castañeda-Martinez; George Kirvassilis; Sophie H Wang; Francesca Manzella; Brant S Swiney; Kobe Masuoka; Saverio Capuano; Kevin G Brunner; Kristin Crosno; Quinton W Guerrero; Hayley Whitson; Ansgar Brambrink; Heather S Simmons; Andres F Mejia; James A Zagzebski; Timothy J Hall; Chrysanthy Ikonomidou
Journal:  Neurobiol Dis       Date:  2019-04-02       Impact factor: 5.996

Review 8.  Review of quantitative multiscale imaging of breast cancer.

Authors:  Michael A Pinkert; Lonie R Salkowski; Patricia J Keely; Timothy J Hall; Walter F Block; Kevin W Eliceiri
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-22

9.  Beyond Cervical Length: A Pilot Study of Ultrasonic Attenuation for Early Detection of Preterm Birth Risk.

Authors:  Barbara L McFarlin; Viksit Kumar; Timothy A Bigelow; Douglas G Simpson; Rosemary C White-Traut; Jacques S Abramowicz; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2015-08-08       Impact factor: 2.998

Review 10.  Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound.

Authors:  Michael L Oelze; Jonathan Mamou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-01-08       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.