Literature DB >> 6491053

Method of data reduction for accurate determination of acoustic backscatter coefficients.

E L Madsen, M F Insana, J A Zagzebski.   

Abstract

In previous methods of data reduction used to determine ultrasonic backscatter coefficients, various approximations were made. One frequently used is that there is an abrupt cutoff in the lateral extent of the scattering volume interrogated. Another approximation in all previous methods is that the effect of time gating the received echo signals can be written as a function of the distance along the axis of the interrogating beam. In the present paper we show that the backscatter coefficient can be derived from experimental data without making such approximations. The cases of narrow-band and broadband pulses are treated, and the method is applicable whatever the distance between the interrogated volume of scatterers and the transducer face. It is shown that, for a given pulse form, the gate duration must be sufficiently long in order to attain a specified accuracy for the measured backscatter coefficient. A test of the method was done using a phantom with well-defined scattering properties. Very good agreement was found between measured values of backscatter coefficients and those calculated using a first-principles theory.

Mesh:

Year:  1984        PMID: 6491053     DOI: 10.1121/1.391317

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  31 in total

1.  Frequency dependence of ultrasonic backscatter from human trabecular bone: theory and experiment.

Authors:  K A Wear
Journal:  J Acoust Soc Am       Date:  1999-12       Impact factor: 1.840

2.  Relationships among calcaneal backscatter, attenuation, sound speed, hip bone mineral density, and age in normal adult women.

Authors:  K A Wear; D W Armstrong
Journal:  J Acoust Soc Am       Date:  2001-07       Impact factor: 1.840

3.  Measurement of dependence of backscatter coefficient from cylinders on frequency and diameter using focused transducers--with applications in trabecular bone.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2004-01       Impact factor: 1.840

4.  The dependence of ultrasonic backscatter on trabecular thickness in human calcaneus: theoretical and experimental results.

Authors:  Keith A Wear; Andres Laib
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-08       Impact factor: 2.725

5.  In vitro characterization of liposomes and Optison by acoustic scattering at 3.5 MHz.

Authors:  Constantin-C Coussios; Christy K Holland; Ludwika Jakubowska; Shao-Ling Huang; Robert C MacDonald; Ashwin Nagaraj; David D McPherson
Journal:  Ultrasound Med Biol       Date:  2004-02       Impact factor: 2.998

6.  Time domain attenuation estimation method from ultrasonic backscattered signals.

Authors:  Goutam Ghoshal; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

7.  Ultrasonic backscatter coefficients for weakly scattering, agar spheres in agar phantoms.

Authors:  Michael R King; Janelle J Anderson; Maria-Teresa Herd; Darryl Ma; Alexander Haak; Lauren A Wirtzfeld; Ernest L Madsen; James A Zagzebski; Michael L Oelze; Timothy J Hall; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2010-08       Impact factor: 1.840

8.  Shape-based ultrasound tomography using a Born model with application to high intensity focused ultrasound therapy.

Authors:  Başak Ulker Karbeyaz; Eric L Miller; Robin O Cleveland
Journal:  J Acoust Soc Am       Date:  2008-05       Impact factor: 1.840

9.  Absolute backscatter coefficient estimates of tissue-mimicking phantoms in the 5-50 MHz frequency range.

Authors:  Matthew M McCormick; Ernest L Madsen; Meagan E Deaner; Tomy Varghese
Journal:  J Acoust Soc Am       Date:  2011-08       Impact factor: 1.840

10.  Mean scatterer spacing estimation in normal and thermally coagulated ex vivo bovine liver.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2014-04       Impact factor: 1.578

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.