Literature DB >> 16464671

Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gels.

Ernest L Madsen1, Maritza A Hobson, Hairong Shi, Tomy Varghese, Gary R Frank.   

Abstract

A set of five tissue-mimicking phantoms with cylindrical inclusions were produced for assessing long-term stability of geometry and elastic properties and assessing accuracy of determination of elastic properties. The base aqueous materials were either gelatin or a mixture of agar and gelatin. Stiffness was controlled by selection of the volume percent consisting of microscopic safflower oil droplets. Cylinder diameters remained unchanged within 1% or 2% over many months. Strain ratios from elastograms of the phantoms were stable over many months, implying that elastic contrasts were also stable. Test samples, called production samples, for measurement of Young's moduli were made at the time of manufacture of each phantom and were stored separately from one another. Each production sample was homogeneous and consisted of either inclusion material or background material. For all five phantoms, it was found that the elastic contrast computed using Young's modulus values determined using the production samples accurately represented the true elastic contrasts in the corresponding phantom. This finding was established by the fact that the (true) elastic contrasts determined using samples excised from the phantoms themselves agreed with the elastic contrasts obtained using the homogeneous production samples.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16464671      PMCID: PMC3769984          DOI: 10.1016/j.ultrasmedbio.2005.10.009

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements.

Authors:  E L Madsen; F Dong; G R Frank; B S Garra; K A Wear; T Wilson; J A Zagzebski; H L Miller; K K Shung; S H Wang; E J Feleppa; T Liu; W D O'Brien; K A Topp; N T Sanghvi; A V Zaitsev; T J Hall; J B Fowlkes; O D Kripfgans; J G Miller
Journal:  J Ultrasound Med       Date:  1999-09       Impact factor: 2.153

2.  Contrast-transfer efficiency for continuously varying tissue moduli: simulation and phantom validation.

Authors:  F Kallel; C D Prihoda; J Ophir
Journal:  Ultrasound Med Biol       Date:  2001-08       Impact factor: 2.998

3.  Tissue-mimicking oil-in-gelatin dispersions for use in heterogeneous elastography phantoms.

Authors:  E L Madsen; G R Frank; T A Krouskop; T Varghese; F Kallel; J Ophir
Journal:  Ultrason Imaging       Date:  2003-01       Impact factor: 1.578

4.  Anthropomorphic 1H MRS head phantom.

Authors:  J R Rice; R H Milbrandt; E L Madsen; G R Frank; E J Boote; J C Blechinger
Journal:  Med Phys       Date:  1998-07       Impact factor: 4.071

  4 in total
  29 in total

1.  Analysis of shear strain imaging for classifying breast masses: finite element and phantom results.

Authors:  Haiyan Xu; Tomy Varghese; Ernest L Madsen
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Volumetric elasticity imaging with a 2-D CMUT array.

Authors:  Ted G Fisher; Timothy J Hall; Satchi Panda; Michael S Richards; Paul E Barbone; Jingfeng Jiang; Jeff Resnick; Steve Barnes
Journal:  Ultrasound Med Biol       Date:  2010-06       Impact factor: 2.998

3.  Shear wave velocity imaging using transient electrode perturbation: phantom and ex vivo validation.

Authors:  Ryan J DeWall; Tomy Varghese; Ernest L Madsen
Journal:  IEEE Trans Med Imaging       Date:  2010-11-11       Impact factor: 10.048

4.  Ultrasonic tracking of shear waves using a particle filter.

Authors:  Atul N Ingle; Chi Ma; Tomy Varghese
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

5.  Spherical lesion phantoms for testing the performance of elastography systems.

Authors:  Ernest L Madsen; Gary R Frank; Maritza A Hobson; Hairong Shi; Jingfeng Jiang; Tomy Varghese; Timothy J Hall
Journal:  Phys Med Biol       Date:  2005-12-06       Impact factor: 3.609

6.  Anthropomorphic breast phantoms for testing elastography systems.

Authors:  Ernest L Madsen; Maritza A Hobson; Gary R Frank; Hairong Shi; Jingfeng Jiang; Timothy J Hall; Tomy Varghese; Marvin M Doyley; John B Weaver
Journal:  Ultrasound Med Biol       Date:  2006-06       Impact factor: 2.998

7.  Normal and shear strain estimation using beam steering on linear-array transducers.

Authors:  M Rao; Q Chen; H Shi; T Varghese; E L Madsen; J A Zagzebski; T A Wilson
Journal:  Ultrasound Med Biol       Date:  2007-01       Impact factor: 2.998

8.  Three-dimensional electrode displacement elastography using the Siemens C7F2 fourSight four-dimensional ultrasound transducer.

Authors:  Shyam Bharat; Ted G Fisher; Tomy Varghese; Timothy J Hall; Jingfeng Jiang; Ernest L Madsen; James A Zagzebski; Fred T Lee
Journal:  Ultrasound Med Biol       Date:  2008-03-28       Impact factor: 2.998

9.  Shear strain imaging using shear deformations.

Authors:  Min Rao; Tomy Varghese; Ernest L Madsen
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

10.  Quantitative assessment of in vivo breast masses using ultrasound attenuation and backscatter.

Authors:  Kibo Nam; James A Zagzebski; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

View more