Literature DB >> 22875599

Challenges and current methods for attenuation correction in PET/MR.

Vincent Keereman1, Pieter Mollet, Yannick Berker, Volkmar Schulz, Stefaan Vandenberghe.   

Abstract

Quantitative PET imaging requires an attenuation map to correct for attenuation. In stand-alone PET or PET/CT, the attenuation map is usually derived from a transmission scan or CT image, respectively. In PET/MR, these methods will most likely not be used. Therefore, attenuation correction has long been regarded as one of the major challenges in the development of PET/MR. In the past few years, much progress has been made in this field. In this review, the challenges faced in attenuation correction for PET/MR are discussed. Different methods have been proposed to overcome these challenges. An overview of the MR-based (template-based and voxel-based), transmission-based and emission-based methods and the results that have been obtained is provided. Although several methods show promising results, no single method fulfils all of the requirements for the ideal attenuation correction method for PET/MR. Therefore, more work is still necessary in this field. To allow implementation in routine clinical practice, extensive evaluation of the proposed methods is necessary to demonstrate robustness and automation.

Mesh:

Substances:

Year:  2012        PMID: 22875599     DOI: 10.1007/s10334-012-0334-7

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  43 in total

1.  Simulation of a MR-PET protocol for staging of head-and-neck cancer including Dixon MR for attenuation correction.

Authors:  Matthias Eiber; Michael Souvatzoglou; Anja Pickhard; Denys J Loeffelbein; Andreas Knopf; Konstantin Holzapfel; Axel Martinez-Möller; Stephan G Nekolla; Elias Q Scherer; Markus Schwaiger; Ernst J Rummeny; Ambros J Beer
Journal:  Eur J Radiol       Date:  2011-11-10       Impact factor: 3.528

2.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography.

Authors:  Habib Zaidi; Marie-Louise Montandon; Daniel O Slosman
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

3.  The effect of errors in segmented attenuation maps on PET quantification.

Authors:  Vincent Keereman; Roel Van Holen; Pieter Mollet; Stefaan Vandenberghe
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

4.  Simultaneous reconstruction of activity and attenuation for PET/MR.

Authors:  André Salomon; Andreas Goedicke; Bernd Schweizer; Til Aach; Volkmar Schulz
Journal:  IEEE Trans Med Imaging       Date:  2010-11-29       Impact factor: 10.048

5.  Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.

Authors:  Bernd J Pichler; Martin S Judenhofer; Ciprian Catana; Jeffrey H Walton; Manfred Kneilling; Robert E Nutt; Stefan B Siegel; Claus D Claussen; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

Review 6.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

7.  MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences.

Authors:  Vincent Keereman; Yves Fierens; Tom Broux; Yves De Deene; Max Lonneux; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2010-05       Impact factor: 10.057

8.  Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

Authors:  Ciprian Catana; Andre van der Kouwe; Thomas Benner; Christian J Michel; Michael Hamm; Matthias Fenchel; Bruce Fischl; Bruce Rosen; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2010-09       Impact factor: 10.057

9.  Atlas-guided non-uniform attenuation correction in cerebral 3D PET imaging.

Authors:  Marie-Louise Montandon; Habib Zaidi
Journal:  Neuroimage       Date:  2005-01-17       Impact factor: 6.556

10.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

View more
  49 in total

Review 1.  Hybrid MR-PET in Neuroimaging.

Authors:  S Bisdas; C Lá Fougere; U Ernemann
Journal:  Clin Neuroradiol       Date:  2015-07-31       Impact factor: 3.649

2.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

Review 3.  Characterization of the impact to PET quantification and image quality of an anterior array surface coil for PET/MR imaging.

Authors:  Scott D Wollenweber; Gaspar Delso; Timothy Deller; David Goldhaber; Martin Hüllner; Patrick Veit-Haibach
Journal:  MAGMA       Date:  2013-06-26       Impact factor: 2.310

Review 4.  Clinical oncologic applications of PET/MRI: a new horizon.

Authors:  Sasan Partovi; Andres Kohan; Christian Rubbert; Jose Luis Vercher-Conejero; Chiara Gaeta; Roger Yuh; Lisa Zipp; Karin A Herrmann; Mark R Robbin; Zhenghong Lee; Raymond F Muzic; Peter Faulhaber; Pablo R Ros
Journal:  Am J Nucl Med Mol Imaging       Date:  2014-03-20

5.  Generation of a Four-Class Attenuation Map for MRI-Based Attenuation Correction of PET Data in the Head Area Using a Novel Combination of STE/Dixon-MRI and FCM Clustering.

Authors:  Parisa Khateri; Hamidreza Saligheh Rad; Amir Homayoun Jafari; Anahita Fathi Kazerooni; Afshin Akbarzadeh; Mohsen Shojae Moghadam; Arvin Aryan; Pardis Ghafarian; Mohammad Reza Ay
Journal:  Mol Imaging Biol       Date:  2015-12       Impact factor: 3.488

6.  Quantitative carotid PET/MR imaging: clinical evaluation of MR-Attenuation correction versus CT-Attenuation correction in (18)F-FDG PET/MR emission data and comparison to PET/CT.

Authors:  Jason Bini; Philip M Robson; Claudia Calcagno; Mootaz Eldib; Zahi A Fayad
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-02-15

7.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

Review 8.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

9.  Evaluation of attenuation correction in cardiac PET using PET/MR.

Authors:  Jeffrey M C Lau; R Laforest; H Sotoudeh; X Nie; S Sharma; J McConathy; E Novak; A Priatna; R J Gropler; P K Woodard
Journal:  J Nucl Cardiol       Date:  2015-10-23       Impact factor: 5.952

10.  Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR.

Authors:  Mark Oehmigen; Maike E Lindemann; Marcel Gratz; Julian Kirchner; Verena Ruhlmann; Lale Umutlu; Jan Ole Blumhagen; Matthias Fenchel; Harald H Quick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-11-09       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.