Literature DB >> 20439508

MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences.

Vincent Keereman1, Yves Fierens, Tom Broux, Yves De Deene, Max Lonneux, Stefaan Vandenberghe.   

Abstract

UNLABELLED: One of the challenges in PET/MRI is the derivation of an attenuation map to correct the PET image for attenuation. Different methods have been suggested for deriving the attenuation map from an MR image. Because the low signal intensity of cortical bone on images acquired with conventional MRI sequences makes it difficult to detect this tissue type, these methods rely on some sort of anatomic precondition to predict the attenuation map, raising the question of whether these methods will be usable in the clinic when patients may exhibit anatomic abnormalities.
METHODS: We propose the use of the transverse relaxation rate, derived from images acquired with an ultrashort echo time sequence to classify the voxels into 1 of 3 tissue classes (bone, soft tissue, or air), without making any assumptions on patient anatomy. Each voxel is assigned a linear attenuation coefficient corresponding to its tissue class. A reference CT scan is used to determine the voxel-by-voxel accuracy of the proposed method. The overall accuracy of the MRI-based attenuation correction is evaluated using a method that takes into account the nonlocal effects of attenuation correction.
RESULTS: As a proof of concept, the head of a pig was used as a phantom for imaging. The new method yielded a correct tissue classification in 90% of the voxels. Five human brain PET/CT and MRI datasets were also processed, yielding slightly worse voxel-by-voxel performance, compared to a CT-derived attenuation map. The PET datasets were reconstructed using the segmented MRI attenuation map derived with the new method, and the resulting images were compared with segmented CT-based attenuation correction. An average error of around 5% was found in the brain.
CONCLUSION: The feasibility of using the transverse relaxation rate map derived from ultrashort echo time MR images for the estimation of the attenuation map was shown on phantom and clinical brain data. The results indicate that the new method, compared with CT-based attenuation correction, yields clinically acceptable errors. The proposed method does not make any assumptions about patient anatomy and could therefore also be used in cases in which anatomic abnormalities are present.

Entities:  

Mesh:

Year:  2010        PMID: 20439508     DOI: 10.2967/jnumed.109.065425

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  138 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET.

Authors:  Xiaofeng Yang; Baowei Fei
Journal:  J Am Med Inform Assoc       Date:  2013-06-12       Impact factor: 4.497

Review 3.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

4.  Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapy.

Authors:  Shu-Hui Hsu; Yue Cao; Ke Huang; Mary Feng; James M Balter
Journal:  Phys Med Biol       Date:  2013-11-11       Impact factor: 3.609

5.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

6.  Accurate PET/MR quantification using time of flight MLAA image reconstruction.

Authors:  R Boellaard; M B M Hofman; O S Hoekstra; A A Lammertsma
Journal:  Mol Imaging Biol       Date:  2014-08       Impact factor: 3.488

Review 7.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

8.  On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

Authors:  Kevin T Chen; David Izquierdo-Garcia; Clare B Poynton; Daniel B Chonde; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-29       Impact factor: 9.236

9.  Positron emission tomography (PET) attenuation correction artefacts in PET/CT and PET/MRI.

Authors:  C Buchbender; V Hartung-Knemeyer; M Forsting; G Antoch; T A Heusner
Journal:  Br J Radiol       Date:  2013-05       Impact factor: 3.039

Review 10.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.