Literature DB >> 21118768

Simultaneous reconstruction of activity and attenuation for PET/MR.

André Salomon1, Andreas Goedicke, Bernd Schweizer, Til Aach, Volkmar Schulz.   

Abstract

Medical investigations targeting a quantitative analysis of the position emission tomography (PET) images require the incorporation of additional knowledge about the photon attenuation distribution in the patient. Today, energy range adapted attenuation maps derived from computer tomography (CT) scans are used to effectively compensate for image quality degrading effects, such as attenuation and scatter. Replacing CT by magnetic resonance (MR) is considered as the next evolutionary step in the field of hybrid imaging systems. However, unlike CT, MR does not measure the photon attenuation and thus does not provide an easy access to this valuable information. Hence, many research groups currently investigate different technologies for MR-based attenuation correction (MR-AC). Typically, these approaches are based on techniques such as special acquisition sequences (alone or in combination with subsequent image processing), anatomical atlas registration, or pattern recognition techniques using a data base of MR and corresponding CT images. We propose a generic iterative reconstruction approach to simultaneously estimate the local tracer concentration and the attenuation distribution using the segmented MR image as anatomical reference. Instead of applying predefined attenuation values to specific anatomical regions or tissue types, the gamma attenuation at 511 keV is determined from the PET emission data. In particular, our approach uses a maximum-likelihood estimation for the activity and a gradient-ascent based algorithm for the attenuation distribution. The adverse effects of scattered and accidental gamma coincidences on the quantitative accuracy of PET, as well as artifacts caused by the inherent crosstalk between activity and attenuation estimation are efficiently reduced using enhanced decay event localization provided by time-of-flight PET, accurate correction for accidental coincidences, and a reduced number of unknown attenuation coefficients. First results achieved with measured whole body PET data and reference segmentation from CT showed an absolute mean difference of 0.005 cm⁻¹ (< 20%) in the lungs, 0.0009 cm⁻¹ (< 2%) in case of fat, and 0.0015 cm⁻¹ (< 2%) for muscles and blood. The proposed method indicates a robust and reliable alternative to other MR-AC approaches targeting patient specific quantitative analysis in time-of-flight PET/MR.

Entities:  

Mesh:

Year:  2010        PMID: 21118768     DOI: 10.1109/TMI.2010.2095464

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  46 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging.

Authors:  David Izquierdo-Garcia; Stephen J Sawiak; Karin Knesaurek; Jagat Narula; Valentin Fuster; Joseph Machac; Zahi A Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-21       Impact factor: 9.236

3.  Quantitative simultaneous positron emission tomography and magnetic resonance imaging.

Authors:  Jinsong Ouyang; Yoann Petibon; Chuan Huang; Timothy G Reese; Aleksandra L Kolnick; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

4.  Direct attenuation correction of brain PET images using only emission data via a deep convolutional encoder-decoder (Deep-DAC).

Authors:  Isaac Shiri; Pardis Ghafarian; Parham Geramifar; Kevin Ho-Yin Leung; Mostafa Ghelichoghli; Mehrdad Oveisi; Arman Rahmim; Mohammad Reza Ay
Journal:  Eur Radiol       Date:  2019-06-21       Impact factor: 5.315

5.  Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience.

Authors:  Edwin E G W Ter Voert; Patrick Veit-Haibach; Sangtae Ahn; Florian Wiesinger; M Mehdi Khalighi; Craig S Levin; Andrei H Iagaru; Greg Zaharchuk; Martin Huellner; Gaspar Delso
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-01-26       Impact factor: 9.236

6.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

7.  Accurate PET/MR quantification using time of flight MLAA image reconstruction.

Authors:  R Boellaard; M B M Hofman; O S Hoekstra; A A Lammertsma
Journal:  Mol Imaging Biol       Date:  2014-08       Impact factor: 3.488

Review 8.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

Review 9.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

Review 10.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.