Literature DB >> 22854009

Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers.

Langechuan Liu1, Larry E Antonuk, Qihua Zhao, Youcef El-Mohri, Hao Jiang.   

Abstract

The imaging performance of active matrix flat-panel imagers designed for megavoltage imaging (MV AMFPIs) is severely constrained by relatively low x-ray detection efficiency, which leads to a detective quantum efficiency (DQE) of only ∼1%. Previous theoretical and empirical studies by our group have demonstrated the potential for addressing this constraint through the utilization of thick, two-dimensional, segmented scintillators with optically isolated crystals. However, this strategy is constrained by the degradation of high-frequency DQE resulting from spatial resolution loss at locations away from the central beam axis due to oblique incidence of radiation. To address this challenge, segmented scintillators constructed so that the crystals are individually focused toward the radiation source are proposed and theoretically investigated. The study was performed using Monte Carlo simulations of radiation transport to examine the modulation transfer function and DQE of focused segmented scintillators with thicknesses ranging from 5 to 60 mm. The results demonstrate that, independent of scintillator thickness, the introduction of focusing largely restores spatial resolution and DQE performance otherwise lost in thick, unfocused segmented scintillators. For the case of a 60 mm thick BGO scintillator and at a location 20 cm off the central beam axis, use of focusing improves DQE by up to a factor of ∼130 at non-zero spatial frequencies. The results also indicate relatively robust tolerance of such scintillators to positional displacements, of up to 10 cm in the source-to-detector direction and 2 cm in the lateral direction, from their optimal focusing position, which could potentially enhance practical clinical use of focused segmented scintillators in MV AMFPIs.

Entities:  

Mesh:

Year:  2012        PMID: 22854009      PMCID: PMC3429122          DOI: 10.1088/0031-9155/57/16/5343

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  24 in total

Review 1.  Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research.

Authors:  Larry E Antonuk
Journal:  Phys Med Biol       Date:  2002-03-21       Impact factor: 3.609

2.  Megavoltage cone-beam computed tomography using a high-efficiency image receptor.

Authors:  Ed J Seppi; Peter Munro; Stan W Johnsen; Ed G Shapiro; Carlo Tognina; Dan Jones; John M Pavkovich; Chris Webb; Ivan Mollov; Larry D Partain; Rick E Colbeth
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-03-01       Impact factor: 7.038

3.  Segmented phosphors: MEMS-based high quantum efficiency detectors for megavoltage x-ray imaging.

Authors:  Amit Sawant; Larry E Antonuk; Youcef El-Mohri; Yixin Li; Zhong Su; Yi Wang; Jin Yamamoto; Qihua Zhao; Hong Du; Jurgen Daniel; Robert Street
Journal:  Med Phys       Date:  2005-02       Impact factor: 4.071

4.  Segmented crystalline scintillators: an initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging.

Authors:  Amit Sawant; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Yixin Li; Zhong Su; Yi Wang; Jin Yamamoto; Hong Du; Ian Cunningham; Misha Klugerman; Kanai Shah
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

5.  Segmented crystalline scintillators: empirical and theoretical investigation of a high quantum efficiency EPID based on an initial engineering prototype CsI(TI) detector.

Authors:  Amit Sawant; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Yi Wang; Yixin Li; Hong Du; Louis Perna
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

6.  Analysis of the kinestatic charge detection system as a high detective quantum efficiency electronic portal imaging device.

Authors:  Sanjiv S Samant; Arun Gopal
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

7.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

8.  A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

9.  Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum.

Authors:  M L Giger; K Doi; C E Metz
Journal:  Med Phys       Date:  1984 Nov-Dec       Impact factor: 4.071

10.  Low-dose megavoltage cone-beam CT for radiation therapy.

Authors:  Jean Pouliot; Ali Bani-Hashemi; Josephine Chen; Michelle Svatos; Farhad Ghelmansarai; Matthias Mitschke; Michele Aubin; Ping Xia; Olivier Morin; Kara Bucci; Mack Roach; Paco Hernandez; Zirao Zheng; Dimitre Hristov; Lynn Verhey
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

View more
  8 in total

1.  A novel EPID design for enhanced contrast and detective quantum efficiency.

Authors:  Joerg Rottmann; Daniel Morf; Rony Fueglistaller; George Zentai; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

2.  Rapid Monte Carlo simulation of detector DQE(f).

Authors:  Josh Star-Lack; Mingshan Sun; Andre Meyer; Daniel Morf; Dragos Constantin; Rebecca Fahrig; Eric Abel
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique.

Authors:  Langechuan Liu; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Hao Jiang
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

4.  Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Authors:  Youcef El-Mohri; Larry E Antonuk; Richard B Choroszucha; Qihua Zhao; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

5.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

6.  Frequency-dependent optimal weighting approach for megavoltage multilayer imagers.

Authors:  Ingrid Valencia Lozano; Mengying Shi; Marios Myronakis; Paul Baturin; Rony Fueglistaller; Pascal Huber; Mathias Lehmann; Daniel Morf; Dianne Ferguson; Matthew W Jacobson; Thomas Harris; Ross I Berbeco; Christopher L Williams
Journal:  Phys Med Biol       Date:  2021-04-16       Impact factor: 4.174

7.  A rapid, accurate image simulation strategy for mega-voltage cone-beam computed tomography.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Mathias Lehmann; Dianne Ferguson; Paul Baturin; Pascal Huber; Rony Fueglistaller; Thomas Harris; Ingrid Valencia Lozano; Christopher Williams; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-07-06       Impact factor: 4.174

8.  ScintSim1: A new Monte Carlo simulation code for transport of optical photons in 2D arrays of scintillation detectors.

Authors:  Mohammad Amin Mosleh-Shirazi; Zinat Zarrini-Monfared; Sareh Karbasi; Ali Zamani
Journal:  J Med Phys       Date:  2014-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.