Literature DB >> 19673222

A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Yi Wang1, Larry E Antonuk, Youcef El-Mohri, Qihua Zhao.   

Abstract

Thick, segmented scintillating detectors, consisting of 2D matrices of scintillator crystals separated by optically opaque septal walls, hold considerable potential for significantly improving the performance of megavoltage (MV) active matrix, flat-panel imagers (AMFPIs). Initial simulation studies of the radiation transport properties of segmented detectors have indicated the possibility of significant improvement in DQE compared to conventional MV AMFPIs based on phosphor screen detectors. It is therefore interesting to investigate how the generation and transport of secondary optical photons affect the DQE performance of such segmented detectors. One effect that can degrade DQE performance is optical Swank noise (quantified by the optical Swank factor I(opt)), which is induced by depth-dependent variations in optical gain. In this study, Monte Carlo simulations of radiation and optical transport have been used to examine I(opt) and zero-frequency DQE for segmented CsI:Tl and BGO detectors at different thicknesses and element-to-element pitches. For these detectors, I(opt) and DQE were studied as a function of various optical parameters, including absorption and scattering in the scintillator, absorption at the top reflector and septal walls, as well as scattering at the side surfaces of the scintillator crystals. The results indicate that I(opt) and DQE are only weakly affected by absorption and scattering in the scintillator, as well as by absorption at the top reflector. However, in some cases, these metrics were found to be significantly degraded by absorption at the septal walls and scattering at the scintillator side surfaces. Moreover, such degradations are more significant for detectors with greater thickness or smaller element pitch. At 1.016 mm pitch and with optimized optical properties, 40 mm thick segmented CsI:Tl and BGO detectors are predicted to provide DQE values of approximately 29% and 42%, corresponding to improvement by factors of approximately 29 and 42, respectively, compared to that of conventional MV AMFPIs.

Mesh:

Year:  2009        PMID: 19673222      PMCID: PMC2805354          DOI: 10.1118/1.3125821

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.

Authors:  L E Antonuk; K W Jee; Y El-Mohri; M Maolinbay; S Nassif; X Rong; Q Zhao; J H Siewerdsen; R A Street; K S Shah
Journal:  Med Phys       Date:  2000-02       Impact factor: 4.071

2.  Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy.

Authors:  C Kausch; B Schreiber; F Kreuder; R Schmidt; O Dössel
Journal:  Med Phys       Date:  1999-10       Impact factor: 4.071

3.  Determination of the detective quantum efficiency of a prototype, megavoltage indirect detection, active matrix flat-panel imager.

Authors:  Y El-Mohri; K W Jee; L E Antonuk; M Maolinbay; Q Zhao
Journal:  Med Phys       Date:  2001-12       Impact factor: 4.071

Review 4.  Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research.

Authors:  Larry E Antonuk
Journal:  Phys Med Biol       Date:  2002-03-21       Impact factor: 3.609

5.  Monte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and image-guided radiotherapy.

Authors:  H Keller; M Glass; R Hinderer; K Ruchala; R Jeraj; G Olivera; T Rock Mackie
Journal:  Med Phys       Date:  2002-02       Impact factor: 4.071

6.  A performance comparison of flat-panel imager-based MV and kV cone-beam CT.

Authors:  B A Groh; J H Siewerdsen; D G Drake; J W Wong; D A Jaffray
Journal:  Med Phys       Date:  2002-06       Impact factor: 4.071

7.  Megavoltage cone-beam computed tomography using a high-efficiency image receptor.

Authors:  Ed J Seppi; Peter Munro; Stan W Johnsen; Ed G Shapiro; Carlo Tognina; Dan Jones; John M Pavkovich; Chris Webb; Ivan Mollov; Larry D Partain; Rick E Colbeth
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-03-01       Impact factor: 7.038

8.  Performance of a 41 x 41 cm2 amorphous silicon flat panel x-ray detector designed for angiographic and R&F imaging applications.

Authors:  Paul R Granfors; Richard Aufrichtig; George E Possin; Brian W Giambattista; Zhong S Huang; Jianqiang Liu; Bing Ma
Journal:  Med Phys       Date:  2003-10       Impact factor: 4.071

9.  Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography.

Authors:  D A Jaffray; J J Battista; A Fenster; P Munro
Journal:  Med Phys       Date:  1995-07       Impact factor: 4.071

10.  A linear array, scintillation crystal-photodiode detector for megavoltage imaging.

Authors:  E J Morton; W Swindell; D G Lewis; P M Evans
Journal:  Med Phys       Date:  1991 Jul-Aug       Impact factor: 4.071

View more
  10 in total

1.  Multi-layer imager design for mega-voltage spectral imaging.

Authors:  Marios Myronakis; Yue-Houng Hu; Rony Fueglistaller; Adam Wang; Paul Baturin; Pascal Huber; Daniel Morf; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-05-10       Impact factor: 3.609

2.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

3.  Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Youcef El-Mohri; Larry E Antonuk; Qihua Zhao
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

4.  Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique.

Authors:  Langechuan Liu; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Hao Jiang
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

5.  Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Richard B Choroszucha; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

6.  A piecewise-focused high DQE detector for MV imaging.

Authors:  Josh Star-Lack; Daniel Shedlock; Dennis Swahn; Dave Humber; Adam Wang; Hayley Hirsh; George Zentai; Daren Sawkey; Isaac Kruger; Mingshan Sun; Eric Abel; Gary Virshup; Mihye Shin; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

7.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

8.  Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers.

Authors:  Langechuan Liu; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Hao Jiang
Journal:  Phys Med Biol       Date:  2012-08-01       Impact factor: 3.609

9.  ScintSim1: A new Monte Carlo simulation code for transport of optical photons in 2D arrays of scintillation detectors.

Authors:  Mohammad Amin Mosleh-Shirazi; Zinat Zarrini-Monfared; Sareh Karbasi; Ali Zamani
Journal:  J Med Phys       Date:  2014-01

10.  Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

Authors:  Jian Liu; Yuan Xu; Aram Teymurazyan; Zisis Papandreou; Geordi Pang
Journal:  Med Phys       Date:  2019-11-04       Impact factor: 4.071

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.