Literature DB >> 6513887

Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum.

M L Giger, K Doi, C E Metz.   

Abstract

We investigated theoretically the effects of various digital parameters, such as sampling aperture, sampling distance, number of quantization levels, and display aperture, on the noise Wiener spectrum of digital radiographic imaging systems. We also measured Wiener spectra for our digital image simulation/processing system, and the results agreed well with the theoretical predictions. Aliasing, which is an artifact caused by undersampling, and the use of a limited number of quantization levels were found to increase the Wiener spectrum for digital systems. The effects of image processing, including unsharp mask filtering, integration, and subtraction, on the Wiener spectrum were also demonstrated. Since noise influences the detectability of radiologic objects and thus diagnostic accuracy, knowledge of the effects of the various digital parameters on the noise spectrum will be useful in the evaluation and design of future digital imaging systems.

Mesh:

Year:  1984        PMID: 6513887     DOI: 10.1118/1.595583

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; D Albagli; S Han; E J Tkaczyk; C E Landberg; B Opsahl-Ong; P R Granfors; I Levis; C J D'Orsi; R E Hendrick
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  Mammographic imaging with a small format CCD-based digital cassette: physical characteristics of a clinical system.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; I Levis; M Sayag; R Kleehammer; R Heidsieck; C J D'Orsi
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

3.  Enhancement of chest images by automatic adaptive spatial filtering.

Authors:  M Souto; J Correa; P G Tahoces; D Tucker; K S Malagari; J J Vidal; R G Fraser
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

4.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis.

Authors:  Yiheng Zhang; Heang-Ping Chan; Berkman Sahiner; Jun Wei; Mitchell M Goodsitt; Lubomir M Hadjiiski; Jun Ge; Chuan Zhou
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

5.  Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Authors:  Claus Koelblinger; Mathias Prokop; Michael Weber; Johannes Sailer; Fabiola Cartes-Zumelzu; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2007-05-10       Impact factor: 5.315

Review 6.  Computer-aided diagnosis in medical imaging: historical review, current status and future potential.

Authors:  Kunio Doi
Journal:  Comput Med Imaging Graph       Date:  2007-03-08       Impact factor: 4.790

Review 7.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

9.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

10.  Accurate MTF measurement in digital radiography using noise response.

Authors:  Andrew Kuhls-Gilcrist; Amit Jain; Daniel R Bednarek; Kenneth R Hoffmann; Stephen Rudin
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

View more