Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Youcef El-Mohri, Larry E Antonuk, Richard B Choroszucha, Qihua Zhao, Hao Jiang, Langechuan Liu.   

Abstract

Thick, segmented crystalline scintillators have shown increasing promise as replacement x-ray converters for the phosphor screens currently used in active matrix flat-panel imagers (AMFPIs) in radiotherapy, by virtue of providing over an order of magnitude improvement in the detective quantum efficiency (DQE). However, element-to-element misalignment in current segmented scintillator prototypes creates a challenge for optimal registration with underlying AMFPI arrays, resulting in degradation of spatial resolution. To overcome this challenge, a methodology involving the use of a relatively high resolution AMFPI array in combination with novel binning techniques is presented. The array, which has a pixel pitch of 0.127 mm, was coupled to prototype segmented scintillators based on BGO, LYSO and CsI:Tl materials, each having a nominal element-to-element pitch of 1.016 mm and thickness of ∼ 1 cm. The AMFPI systems incorporating these prototypes were characterized at a radiotherapy energy of 6 MV in terms of modulation transfer function, noise power spectrum, DQE, and reconstructed images of a resolution phantom acquired using a cone-beam CT geometry. For each prototype, the application of 8 × 8 pixel binning to achieve a sampling pitch of 1.016 mm was optimized through use of an alignment metric which minimized misregistration and thereby improved spatial resolution. In addition, the application of alternative binning techniques that exclude the collection of signal near septal walls resulted in further significant improvement in spatial resolution for the BGO and LYSO prototypes, though not for the CsI:Tl prototype due to the large amount of optical cross-talk resulting from significant light spread between scintillator elements in that device. The efficacy of these techniques for improving spatial resolution appears to be enhanced for scintillator materials that exhibit mechanical hardness, high density and high refractive index, such as BGO. Moreover, materials that exhibit these properties as well as offer significantly higher light output than BGO, such as CdWO4, should provide the additional benefit of preserving DQE performance.

Entities:  

Mesh:

Year:  2014        PMID: 24487347      PMCID: PMC4061715          DOI: 10.1088/0031-9155/59/4/797

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  30 in total

1.  Megavoltage cone-beam computed tomography using a high-efficiency image receptor.

Authors:  Ed J Seppi; Peter Munro; Stan W Johnsen; Ed G Shapiro; Carlo Tognina; Dan Jones; John M Pavkovich; Chris Webb; Ivan Mollov; Larry D Partain; Rick E Colbeth
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-03-01       Impact factor: 7.038

2.  A megavoltage CT scanner for radiotherapy verification.

Authors:  D G Lewis; W Swindell; E J Morton; P M Evans; Z R Xiao
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

3.  Segmented crystalline scintillators: empirical and theoretical investigation of a high quantum efficiency EPID based on an initial engineering prototype CsI(TI) detector.

Authors:  Amit Sawant; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Yi Wang; Yixin Li; Hong Du; Louis Perna
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

4.  A bench-top megavoltage fan-beam CT using CdWO4-photodiode detectors. II. Image performance evaluation.

Authors:  T T Monajemi; D Tu; B G Fallone; S Rathee
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

5.  Slit design for efficient and accurate MTF measurement at megavoltage x-ray energies.

Authors:  Amit Sawant; Larry Antonuk; Youcef El-Mohri
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

6.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

7.  An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays.

Authors:  Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Hong Du; Yi Wang; Robert A Street; Jackson Ho; Richard Weisfield; William Yao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

8.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

9.  Low-dose megavoltage cone-beam CT for radiation therapy.

Authors:  Jean Pouliot; Ali Bani-Hashemi; Josephine Chen; Michelle Svatos; Farhad Ghelmansarai; Matthias Mitschke; Michele Aubin; Ping Xia; Olivier Morin; Kara Bucci; Mack Roach; Paco Hernandez; Zirao Zheng; Dimitre Hristov; Lynn Verhey
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-02-01       Impact factor: 7.038

Review 10.  Megavoltage cone-beam CT: system description and clinical applications.

Authors:  Olivier Morin; Amy Gillis; Josephine Chen; Michèle Aubin; M Kara Bucci; Mack Roach; Jean Pouliot
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

View more
  1 in total

1.  Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique.

Authors:  Langechuan Liu; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Hao Jiang
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.