A comprehensive formulation for volumetric modulated arc therapy planning.

Dan Nguyen1, Qihui Lyu1, Dan Ruan1, Daniel O'Connor1, Daniel A Low1, Ke Sheng1.   

Abstract

PURPOSE: Volumetric modulated arc therapy (VMAT) is a widely employed radiation therapy technique, showing comparable dosimetry to static beam intensity modulated radiation therapy (IMRT) with reduced monitor units and treatment time. However, the current VMAT optimization has various greedy heuristics employed for an empirical solution, which jeopardizes plan consistency and quality. The authors introduce a novel direct aperture optimization method for VMAT to overcome these limitations.
METHODS: The comprehensive VMAT (comVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term to penalize the difference between the optimized dose and the prescribed dose, as well as an anisotropic total variation term to promote piecewise continuity in the fluence maps, preparing it for direct aperture optimization. A level set function was used to describe the aperture shapes and the difference between aperture shapes at adjacent angles was penalized to control MLC motion range. A proximal-class optimization solver was adopted to solve the large scale optimization problem, and an alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc comVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme case, a lung (LNG) case, and two head and neck cases-one with three PTVs (H&N3PTV) and one with foue PTVs (H&N4PTV)-to test the efficacy. The plans were optimized using an alternating optimization strategy. The plans were compared against the clinical VMAT (clnVMAT) plans utilizing two overlapping coplanar arcs for treatment.
RESULTS: The optimization of the comVMAT plans had converged within 600 iterations of the block minimization algorithm. comVMAT plans were able to consistently reduce the dose to all organs-at-risk (OARs) as compared to the clnVMAT plans. On average, comVMAT plans reduced the max and mean OAR dose by 6.59% and 7.45%, respectively, of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N3PTV case. PTV coverages measured by D95, D98, and D99 were within 0.25% of the prescription dose. By comprehensively optimizing all beams, the comVMAT optimizer gained the freedom to allow some selected beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization.
CONCLUSIONS: The novel nongreedy VMAT approach simultaneously optimizes all beams in an arc and then directly generates deliverable apertures. The single arc VMAT approach thus fully utilizes the digital Linac's capability in dose rate and gantry rotation speed modulation. In practice, the new single VMAT algorithm generates plans superior to existing VMAT algorithms utilizing two arcs.

Entities:  

Mesh:

Year:  2016        PMID: 27370141      PMCID: PMC4912562          DOI: 10.1118/1.4953832

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  27 in total

1.  Comparison of algorithms for multileaf collimator field segmentation.

Authors:  W Que
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans.

Authors:  Motohiro Kawashima; Shuichi Ozawa; Akihiro Haga; Akira Sakumi; Chie Kurokawa; Satoru Sugimoto; Kumiko Karasawa; Keiichi Nakagawa; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2012-07-01

3.  An arc-sequencing algorithm for intensity modulated arc therapy.

Authors:  D M Shepard; D Cao; M K N Afghan; M A Earl
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

4.  An exact approach to direct aperture optimization in IMRT treatment planning.

Authors:  Chunhua Men; H Edwin Romeijn; Z Caner Taşkin; James F Dempsey
Journal:  Phys Med Biol       Date:  2007-12-05       Impact factor: 3.609

5.  2-Step IMAT and 2-Step IMRT in three dimensions.

Authors:  Klaus Bratengeier
Journal:  Med Phys       Date:  2005-12       Impact factor: 4.071

6.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

7.  Single-Arc IMRT?

Authors:  Thomas Bortfeld; Steve Webb
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

8.  Using total-variation regularization for intensity modulated radiation therapy inverse planning with field-specific numbers of segments.

Authors:  Lei Zhu; Louis Lee; Yunzhi Ma; Yinyu Ye; Rafe Mazzeo; Lei Xing
Journal:  Phys Med Biol       Date:  2008-11-07       Impact factor: 3.609

Review 9.  Advances in treatment techniques: arc-based and other intensity modulated therapies.

Authors:  Jian-Yue Jin; Ning Wen; Lei Ren; Carri Glide-Hurst; Indrin J Chetty
Journal:  Cancer J       Date:  2011 May-Jun       Impact factor: 3.360

10.  Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study.

Authors:  Wilko F A R Verbakel; Johan P Cuijpers; Daan Hoffmans; Michael Bieker; Ben J Slotman; Suresh Senan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-05-01       Impact factor: 7.038

View more
  11 in total

1.  VMAT optimization with dynamic collimator rotation.

Authors:  Qihui Lyu; Daniel O'Connor; Dan Ruan; Victoria Yu; Dan Nguyen; Ke Sheng
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

2.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

3.  Use of proximal operator graph solver for radiation therapy inverse treatment planning.

Authors:  Xinmin Liu; Charles Pelizzari; Andrew H Belcher; Zachary Grelewicz; Rodney D Wiersma
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

4.  Deterministic direct aperture optimization using multiphase piecewise constant segmentation.

Authors:  Dan Nguyen; Daniel O'Connor; Dan Ruan; Ke Sheng
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

5.  Using deep learning to predict beam-tunable Pareto optimal dose distribution for intensity-modulated radiation therapy.

Authors:  Gyanendra Bohara; Azar Sadeghnejad Barkousaraie; Steve Jiang; Dan Nguyen
Journal:  Med Phys       Date:  2020-08-02       Impact factor: 4.071

6.  A novel optimization framework for VMAT with dynamic gantry couch rotation.

Authors:  Qihui Lyu; Victoria Y Yu; Dan Ruan; Ryan Neph; Daniel O'Connor; Ke Sheng
Journal:  Phys Med Biol       Date:  2018-06-13       Impact factor: 3.609

7.  Solving the volumetric modulated arc therapy (VMAT) problem using a sequential convex programming method.

Authors:  Pınar Dursun; Masoud Zarepisheh; Gourav Jhanwar; Joseph O Deasy
Journal:  Phys Med Biol       Date:  2021-04-14       Impact factor: 4.174

8.  A fast optimization approach for treatment planning of volumetric modulated arc therapy.

Authors:  Hui Yan; Jian-Rong Dai; Ye-Xiong Li
Journal:  Radiat Oncol       Date:  2018-05-30       Impact factor: 3.481

9.  ROAD: ROtational direct Aperture optimization with a Decoupled ring-collimator for FLASH radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Daniel O'Connor; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2021-01-29       Impact factor: 3.609

10.  A feasibility study for predicting optimal radiation therapy dose distributions of prostate cancer patients from patient anatomy using deep learning.

Authors:  Dan Nguyen; Troy Long; Xun Jia; Weiguo Lu; Xuejun Gu; Zohaib Iqbal; Steve Jiang
Journal:  Sci Rep       Date:  2019-01-31       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.