Literature DB >> 19540062

Volumetric modulated arc therapy: planning and evaluation for prostate cancer cases.

Pengpeng Zhang1, Laura Happersett, Margie Hunt, Andrew Jackson, Michael Zelefsky, Gig Mageras.   

Abstract

PURPOSE: To develop an optimization method using volumetric modulated arc therapy (VMAT) and evaluate VMAT plans relative to the standard intensity-modulated radiotherapy (IMRT) approach in prostate cancer. METHODS AND MATERIALS: A single gantry rotation was modeled using 177 equispaced beams. Multileaf collimator apertures and dose rates were optimized with respect to gantry angle subject to dose-volume-based objectives. Our VMAT implementation used conjugate gradient descent to optimize dose rate, and stochastic sampling to find optimal multileaf collimator leaf positions. A treatment planning study of 11 prostate cancer patients with a prescription dose of 86.4 Gy was performed to compare VMAT with a standard five-field IMRT approach. Plan evaluation statistics included the percentage of planning target volume (PTV) receiving 95% of prescribed dose (V95), dose to 95% of PTV (D95), mean PTV dose, tumor control probability, and dosimetric endpoints of normal organs, whereas monitor unit (MU) and delivery time were used to assess delivery efficiency.
RESULTS: Patient-averaged PTV V95, D95, mean dose, and tumor control probability in VMAT plans were 96%, 82.6 Gy, 88.5 Gy, and 0.920, respectively, vs. 97%, 84.0 Gy, 88.9 Gy, and 0.929 in IMRT plans. All critical structure dose requirements were met. The VMAT plans presented better rectal wall sparing, with a reduction of 1.5% in normal tissue complication probability. An advantage of VMAT plans was that the average number of MUs (290 MU) was less than for IMRT plans (642 MU).
CONCLUSION: The VMAT technique can reduce beam on time by up to 55% while maintaining dosimetric quality comparable to that of the standard IMRT approach.

Entities:  

Mesh:

Year:  2009        PMID: 19540062     DOI: 10.1016/j.ijrobp.2009.03.033

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  78 in total

Review 1.  Volumetric modulated arc therapy: a review of current literature and clinical use in practice.

Authors:  M Teoh; C H Clark; K Wood; S Whitaker; A Nisbet
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

2.  Multicriteria VMAT optimization.

Authors:  David Craft; Dualta McQuaid; Jeremiah Wala; Wei Chen; Ehsan Salari; Thomas Bortfeld
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Comparison of total MU and segment areas in VMAT and step-and-shoot IMRT plans.

Authors:  Motohiro Kawashima; Shuichi Ozawa; Akihiro Haga; Akira Sakumi; Chie Kurokawa; Satoru Sugimoto; Kumiko Karasawa; Keiichi Nakagawa; Keisuke Sasai
Journal:  Radiol Phys Technol       Date:  2012-07-01

4.  RapidArc vs intensity-modulated radiation therapy for hepatocellular carcinoma: a comparative planning study.

Authors:  J M Park; K Kim; E K Chie; C H Choi; S J Ye; S W Ha
Journal:  Br J Radiol       Date:  2012-07       Impact factor: 3.039

5.  Dose correction strategy for the optimization of volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Jie Yang; Margie Hunt; Gig Mageras
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

6.  Inverse planning for four-dimensional (4D) volumetric modulated arc therapy.

Authors:  Yunzhi Ma; Daniel Chang; Paul Keall; Yiaoqin Xie; Jae-yoon Park; Tae-suk Suh; Lei Xing
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

7.  FusionArc optimization: a hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy.

Authors:  Martha M Matuszak; Jennifer M Steers; Troy Long; Daniel L McShan; Benedick A Fraass; H Edwin Romeijn; Randall K Ten Haken
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

8.  A dosimetric comparison of RapidArc and IMRT with hypofractionated simultaneous integrated boost to the prostate for treatment of prostate cancer.

Authors:  K Ishii; R Ogino; W Okada; R Nakahara; R Kawamorita; T Nakajima
Journal:  Br J Radiol       Date:  2013-08-30       Impact factor: 3.039

9.  Exploring trade-offs between VMAT dose quality and delivery efficiency using a network optimization approach.

Authors:  Ehsan Salari; Jeremiah Wala; David Craft
Journal:  Phys Med Biol       Date:  2012-08-14       Impact factor: 3.609

10.  Automated volumetric modulated Arc therapy treatment planning for stage III lung cancer: how does it compare with intensity-modulated radio therapy?

Authors:  Enzhuo M Quan; Joe Y Chang; Zhongxing Liao; Tingyi Xia; Zhiyong Yuan; Hui Liu; Xiaoqiang Li; Cody A Wages; Radhe Mohan; Xiaodong Zhang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-09-01       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.