Literature DB >> 22735977

Evaluation of the accuracy of a patient-specific instrumentation by navigation.

Fabio Conteduca1, Raffaele Iorio, Daniele Mazza, Ludovico Caperna, Gabriele Bolle, Giuseppe Argento, Andrea Ferretti.   

Abstract

PURPOSE: The aim of this study is to evaluate the accuracy of a patient-specific instrumentation (PSI) as assessed by the intraoperative use of knee navigation software during the surgical procedure.
METHODS: Fifteen patients with primary gonarthrosis were selected for unilateral total knee arthroplasty. The first three patients were excluded from this study, as they were considered to be a warm up to set-up the procedure. All patients were operated on with a cemented posterior-stabilised prosthesis cruciate ligament-sacrificing by the same surgeon using the patient matched cutting jigs. The size of the implant, level of resection, and alignment in the coronal and sagittal planes were evaluated. An unsatisfactory result was considered an error ≥2° in both planes for each component as a possible error of 4° could result in aggravation.
RESULTS: On the coronal plane the mean deviation of the tibial guide from the ideal alignment was 1.2 ± 1.5 (range 0-5°) and in the sagittal plane was 3.8 ± 2.4 (range 0-7.5°). On the coronal plane the mean deviation of the femoral guide from the ideal alignment was 1.2 ± 0.6 and in the sagittal was 3.7 ± 2.
CONCLUSION: On the basis of this preliminary experience the PSI system based only on data acquisition with A-P radiograms and RMN cannot be defined as accurate. In cases of the use of the custom made cutting jigs it is recommended to perform an accurate control of the alignment before making the cuts, for any step of the procedure. LEVEL OF EVIDENCE: II.

Entities:  

Mesh:

Year:  2012        PMID: 22735977     DOI: 10.1007/s00167-012-2098-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  19 in total

1.  Custom-fit total knee arthroplasty (OtisKnee) results in malalignment.

Authors:  Brian A Klatt; Nitin Goyal; Matthew S Austin; William J Hozack
Journal:  J Arthroplasty       Date:  2008-01       Impact factor: 4.757

2.  Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty.

Authors:  Fabio Catani; Nicola Biasca; Andrea Ensini; Alberto Leardini; Luca Bianchi; Vitantonio Digennaro; Sandro Giannini
Journal:  J Bone Joint Surg Am       Date:  2008-04       Impact factor: 5.284

Review 3.  Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials?

Authors:  Tao Cheng; Song Zhao; Xiaochun Peng; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-06       Impact factor: 4.342

4.  Mechanisms of failure in total knee arthroplasty.

Authors:  J R Moreland
Journal:  Clin Orthop Relat Res       Date:  1988-01       Impact factor: 4.176

5.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations.

Authors:  J H Bargren; J D Blaha; M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

6.  Navigation-assisted total knee arthroplasty in knees with osteoarthritis due to extra-articular deformity.

Authors:  Fabio Catani; Vitantonio Digennaro; Andrea Ensini; Alberto Leardini; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-29       Impact factor: 4.342

7.  Can computer assistance improve the clinical and functional scores in total knee arthroplasty?

Authors:  Daniel Hernández-Vaquero; Abelardo Suarez-Vazquez; Susana Iglesias-Fernandez
Journal:  Clin Orthop Relat Res       Date:  2011-08-27       Impact factor: 4.176

8.  The value of patient-matched instrumentation in total knee arthroplasty.

Authors:  John W Noble; Chris A Moore; Ning Liu
Journal:  J Arthroplasty       Date:  2011-09-09       Impact factor: 4.757

9.  Residual varus alignment does not compromise results of TKAs in patients with preoperative varus.

Authors:  Robert A Magnussen; Florent Weppe; Guillaume Demey; Elvire Servien; Sébastien Lustig
Journal:  Clin Orthop Relat Res       Date:  2011-07-26       Impact factor: 4.176

10.  The cost-effectiveness of computer-assisted navigation in total knee arthroplasty.

Authors:  Erik J Novak; Marc D Silverstein; Kevin J Bozic
Journal:  J Bone Joint Surg Am       Date:  2007-11       Impact factor: 5.284

View more
  31 in total

1.  Assessing the accuracy of patient-specific guides for total knee arthroplasty.

Authors:  Jong-Keun Seon; Hyeong-Won Park; Seung-Hyun Yoo; Eun-Kyoo Song
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-11-16       Impact factor: 4.342

2.  Assessment of patient-specific instrumentation precision through bone resection measurements.

Authors:  F Zambianchi; A Colombelli; V Digennaro; A Marcovigi; R Mugnai; F Fiacchi; D Sandoni; A Belluati; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-24       Impact factor: 4.342

3.  The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty.

Authors:  Jerry Yongqiang Chen; Seng Jin Yeo; Andy Khye Soon Yew; Darren Keng Jin Tay; Shi-Lu Chia; Ngai Nung Lo; Pak Lin Chin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-31       Impact factor: 4.342

4.  Custom-fit total knee arthroplasty: our initial experience with 30 knees.

Authors:  Enrico Bonicoli; Lorenzo Andreani; Paolo Parchi; Nicola Piolanti; Michele Lisanti
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-09-06

Review 5.  No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.

Authors:  Huichao Fu; Jiaxing Wang; Shenyuan Zhou; Tao Cheng; Wen Zhang; Qi Wang; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

6.  Inter-observer precision and physiologic variability of mri landmarks used to determine rotational alignment in conventional and patient-specific TKA.

Authors:  Andrew Park; Denis Nam; Michael V Friedman; Stephen T Duncan; Travis J Hillen; Robert L Barrack
Journal:  J Arthroplasty       Date:  2014-09-06       Impact factor: 4.757

7.  Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

Authors:  Corey Scholes; Varun Sahni; Sebastien Lustig; David A Parker; Myles R J Coolican
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-17       Impact factor: 4.342

8.  [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].

Authors:  C O Tibesku
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

9.  Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Jan Victor; Jan Dujardin; Hilde Vandenneucker; Nele Arnout; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

10.  Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study.

Authors:  Andrzej Kotela; Ireneusz Kotela
Journal:  Int Orthop       Date:  2014-06-28       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.