Literature DB >> 21908169

The value of patient-matched instrumentation in total knee arthroplasty.

John W Noble1, Chris A Moore, Ning Liu.   

Abstract

The purpose of the current prospective, randomized study was to compare the value of a new mechanically aligned patient-matched instrument system for total knee arthroplasty (TKA) (Visionaire; Smith & Nephew, Inc, Memphis, Tenn) (VIS) to that of standard TKA surgical instrumentation (STD). Twenty-nine primary TKA patients were enrolled and completed surgery (15 VIS and 14 STD). Postoperatively, mechanical alignment was significantly closer to neutral zero in the VIS group (1.7° vs 2.8°; P = .03). Furthermore, the VIS group demonstrated significant reductions in duration of hospital stay, operative time, incision length, and number of used instrument trays (P < .05). Although additional research is underway to confirm these preliminary results, this evidence suggests that patient-matched instrumentation may support repeatable improvements in surgical accuracy and hospital efficiency.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21908169     DOI: 10.1016/j.arth.2011.07.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  70 in total

1.  Assessment of patient-specific instrumentation precision through bone resection measurements.

Authors:  F Zambianchi; A Colombelli; V Digennaro; A Marcovigi; R Mugnai; F Fiacchi; D Sandoni; A Belluati; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-24       Impact factor: 4.342

Review 2.  No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.

Authors:  Huichao Fu; Jiaxing Wang; Shenyuan Zhou; Tao Cheng; Wen Zhang; Qi Wang; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

3.  Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial.

Authors:  Tilman Pfitzner; Matthew P Abdel; Philipp von Roth; Carsten Perka; Hagen Hommel
Journal:  Clin Orthop Relat Res       Date:  2014-07-15       Impact factor: 4.176

4.  Accuracy of Individualized Custom Tibial Cutting Guides in UKA.

Authors:  Thomas J Heyse; Joseph D Lipman; Carl W Imhauser; Scott M Tucker; Yogesh Rajak; Geoffrey H Westrich
Journal:  HSS J       Date:  2014-09-09

5.  Inter-observer precision and physiologic variability of mri landmarks used to determine rotational alignment in conventional and patient-specific TKA.

Authors:  Andrew Park; Denis Nam; Michael V Friedman; Stephen T Duncan; Travis J Hillen; Robert L Barrack
Journal:  J Arthroplasty       Date:  2014-09-06       Impact factor: 4.757

6.  Are MRI-based, patient matched cutting jigs as accurate as the tibial guides?

Authors:  Fabio Conteduca; Raffaele Iorio; Daniele Mazza; Ludovico Caperna; Gabriele Bolle; Giuseppe Argento; Andrea Ferretti
Journal:  Int Orthop       Date:  2012-03-18       Impact factor: 3.075

7.  Evolution of customization design for total knee arthroplasty.

Authors:  John Slamin; Brian Parsley
Journal:  Curr Rev Musculoskelet Med       Date:  2012-12

8.  Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation.

Authors:  Corey Scholes; Varun Sahni; Sebastien Lustig; David A Parker; Myles R J Coolican
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-17       Impact factor: 4.342

9.  Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides.

Authors:  David H Ballard; Patrick Mills; Richard Duszak; Jeffery A Weisman; Frank J Rybicki; Pamela K Woodard
Journal:  Acad Radiol       Date:  2019-09-18       Impact factor: 3.173

10.  [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].

Authors:  C O Tibesku
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.