Literature DB >> 21789710

Residual varus alignment does not compromise results of TKAs in patients with preoperative varus.

Robert A Magnussen1, Florent Weppe, Guillaume Demey, Elvire Servien, Sébastien Lustig.   

Abstract

BACKGROUND: Postoperative varus alignment has been associated with lower IKS scores and increased failure rates. Appropriate positioning of TKA components therefore is a key concern of surgeons. However, obtaining neutral alignment can be challenging in patients with substantial preoperative varus deformity and it is unclear whether residual deformity influences revision rates. QUESTIONS/PURPOSES: We asked: (1) in patients with preoperative varus deformities, does residual postoperative varus limb alignment lead to increased revision rates or lower IKS scores compared with correction to neutral alignment, (2) does placing the tibial component in varus alignment lead to increased revision rates and lower IKS scores, (3) does femoral component alignment affect revision rates and IKS scores, and (4) do these findings change in patients with at least 10° varus alignment preoperatively? PATIENTS AND METHODS: From a prospective database, we identified 553 patients undergoing TKAs for varus osteoarthritis. Patients were divided into those with residual postoperative varus and those with neutral postoperative alignment. Revision rates and International Knee Society (IKS) scores were compared between the two groups and assessed based on postoperative component alignment. Survival analysis was conducted with revision as the endpoint. The analysis was repeated in a subgroup of patients with at least 10° preoperative varus. Minimum followup was 2 years (median, 4.7 years; range, 2-19.8 years).
RESULTS: The two groups had similar survival rates to 10 years and similar IKS scores. Varus tibial component alignment and valgus femoral component alignment were associated with lower mean scores. Revision rates and scores were similar in a subgroup of patients with substantial preoperative varus.
CONCLUSIONS: Our data suggest residual postoperative varus deformity after TKA does not increase survival rates at medium-term in patients with preoperative varus deformities, providing tibial component varus is avoided. Tibial component varus negatively influences IKS score. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2011        PMID: 21789710      PMCID: PMC3210258          DOI: 10.1007/s11999-011-1988-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  28 in total

1.  Tibial component failure mechanisms in total knee arthroplasty.

Authors:  Michael E Berend; Merrill A Ritter; John B Meding; Philip M Faris; E Michael Keating; Ryan Redelman; Gregory W Faris; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

2.  The influence of postoperative coronal alignment on revision surgery in total knee arthroplasty.

Authors:  Samer S Morgan; A Bonshahi; N Pradhan; A Gregory; A Gambhir; M L Porter
Journal:  Int Orthop       Date:  2007-07-05       Impact factor: 3.075

3.  Soft tissue balancing in varus total knee arthroplasty: an algorithmic approach.

Authors:  Peter C M Verdonk; Jerome Pernin; Alban Pinaroli; Tarik Ait Si Selmi; Philippe Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-17       Impact factor: 4.342

4.  Coronal alignment after total knee replacement.

Authors:  R S Jeffery; R W Morris; R A Denham
Journal:  J Bone Joint Surg Br       Date:  1991-09

5.  The influence of coronal plane deformity on mediolateral ligament status: an observational study in varus knees.

Authors:  Johan Bellemans; H Vandenneucker; J Vanlauwe; J Victor
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-02       Impact factor: 4.342

6.  Frontal plane knee alignment: a call for standardized measurement.

Authors:  T Derek V Cooke; Elizabeth A Sled; R Allan Scudamore
Journal:  J Rheumatol       Date:  2007-09       Impact factor: 4.666

7.  Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties.

Authors:  J H Lonner; M T Laird; S A Stuchin
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

8.  Mechanisms of failure in total knee arthroplasty.

Authors:  J R Moreland
Journal:  Clin Orthop Relat Res       Date:  1988-01       Impact factor: 4.176

9.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations.

Authors:  J H Bargren; J D Blaha; M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

10.  Varus gonarthrosis predisposes to varus malalignment in TKA.

Authors:  Thomas J Heyse; Ralf Decking; Jack Davis; Friedrich Boettner; Richard S Laskin
Journal:  HSS J       Date:  2009-05-20
View more
  59 in total

1.  Assessing the accuracy of patient-specific guides for total knee arthroplasty.

Authors:  Jong-Keun Seon; Hyeong-Won Park; Seung-Hyun Yoo; Eun-Kyoo Song
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-11-16       Impact factor: 4.342

2.  Accuracy of manual instrumentation of tibial cutting guide in total knee arthroplasty.

Authors:  R Iorio; G Bolle; F Conteduca; L Valeo; J Conteduca; D Mazza; A Ferretti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-24       Impact factor: 4.342

Review 3.  Shorter survival rate in varus-aligned knees after total knee arthroplasty.

Authors:  Hai-Xiao Liu; Ping Shang; Xiao-Zhou Ying; Yu Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-16       Impact factor: 4.342

4.  Do manual cutting guides for total knee arthroplasty introduce systematic error?

Authors:  Erik Hohmann; Kevin Tetsworth
Journal:  Int Orthop       Date:  2015-08-23       Impact factor: 3.075

5.  Slight under-correction using individualized intentional varus femoral cutting leads to favorable outcomes in patients with lateral femoral bowing and varus knee.

Authors:  Han-Jun Lee; Jung-Won Lim; Dong-Hoon Lee; Dong-Hyun Kim; Yong-Beom Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-22       Impact factor: 4.342

6.  The orientation of the surgical epicondylar axis varies in varus and non-varus knees in the coronal plane.

Authors:  Yunjie Zhang; Xiaofeng Wang; Yunchao Shao; Qing Xia
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-28       Impact factor: 4.342

7.  Kinematically aligned total knee arthroplasty: alternative standardized technique?

Authors:  Tomoyuki Matsumoto; Koji Takayama; Kazunari Ishida; Shinya Hayashi; Shingo Hashimoto; Ryosuke Kuroda
Journal:  Ann Transl Med       Date:  2017-05

8.  Over-voluming predicted by pre-operative planning in 24% of total knee arthroplasty.

Authors:  Simon Marmor; Eric Renault; Jeremy Valluy; Mo Saffarini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-06-02       Impact factor: 4.342

9.  Minimal under-correction gives better outcomes following total knee arthroplasty in severe varus knees-myth or reality?-analysis of one hundred sixty two knees with varus greater than fifteen degrees.

Authors:  Raja Bhaskara Rajasekaran; Dhanasekara Raja Palanisami; Rajkumar Natesan; Shanmuganathan Rajasekaran
Journal:  Int Orthop       Date:  2018-11-20       Impact factor: 3.075

Review 10.  Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.

Authors:  Yong Seuk Lee; Stephen M Howell; Ye-Yeon Won; O-Sung Lee; Seung Hoon Lee; Hamed Vahedi; Seow Hui Teo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.