Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study.

Wen Jie Yang1, Ke Min Chen, Bo Liu, Li Fang Pang, Huan Zhang, Zi Lai Pan, Fu Hua Yan.   

Abstract

To investigate the feasibility of contrast media (CM) volume reduction in dual-source coronary computed tomography angiography high-pitch mode without affecting coronary artery enhancement. Eighty patients were involved in a preliminary experiment with a default injection protocol (60 ml of CM). The age, BMI, test bolus (TB) enhancement peak and the CT values of coronary artery for each patient were recorded and the key factors for determining coronary artery enhancement were investigated. Based on the results of the preliminary experiment, 120 patients were involved in the main experiment with a new injection protocol. For each patient, the CT values and noise of left coronary sinus (LCS), and the distal segment of right coronary artery were measured. In the preliminary experiment, the peak enhancement of TB correlated most strongly with the HU values of coronary artery. Consequently, the new injection protocol was devised to catalog patients into four groups (30, 40, 50 and 60 ml) of CM based on their TB peak enhancement. In the main experiment, the 30 ml CM injection group whose peak attenuation of TB were the highest (30 vs. 40,50,60 ml: 323.0 ± 27.5 vs. 264.2 ± 11.9, 242.1 ± 8.8, 206.2 ± 18.2 HU, p < 0.05), obtained the highest attenuation of LCS (30 vs. 40,50,60 ml: 365.0 ± 41.2 vs. 341.8 ± 40.0, 326.9 ± 34.7, 312.5 ± 38.2 HU p < 0.05). Contrast optimization is feasible in high-pitch DSCT coronary angiography. Certain patients may receive 30 ml of CM without affecting vessel enhancement.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22618434     DOI: 10.1007/s10554-012-0068-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  24 in total

1.  Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

Authors:  K Hittmair; D Fleischmann
Journal:  J Comput Assist Tomogr       Date:  2001 Mar-Apr       Impact factor: 1.826

2.  Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population: comparison with conventional invasive angiography.

Authors:  Mariko Ehara; Jean-Francois Surmely; Masato Kawai; Osamu Katoh; Tetsuo Matsubara; Mitsuyasu Terashima; Etsuo Tsuchikane; Yoshihisa Kinoshita; Tomomichi Suzuki; Tatsuya Ito; Yoshihiro Takeda; Kenya Nasu; Nobuyoshi Tanaka; Akira Murata; Yasuyuki Suzuki; Koyo Sato; Takahiko Suzuki
Journal:  Circ J       Date:  2006-05       Impact factor: 2.993

Review 3.  The clinical and renal consequences of contrast-induced nephropathy.

Authors:  William F Finn
Journal:  Nephrol Dial Transplant       Date:  2006-06       Impact factor: 5.992

4.  Feasibility of low-volume injections of contrast material with a body weight-adapted iodine-dose protocol in 320-detector row coronary CT angiography.

Authors:  Fuminari Tatsugami; Mitsuru Matsuki; Yuki Inada; Shuji Kanazawa; Go Nakai; Yoshihiro Takeda; Hideaki Morita; Haruhiko Takada; Kenji Ashida; Shushi Yoshikawa; Katsunori Fukumura; Yoshifumi Narumi
Journal:  Acad Radiol       Date:  2009-11-17       Impact factor: 3.173

5.  Coronary enhancement for prospective ECG-gated single R-R axial 320-MDCT angiography: comparison of 60- and 80-mL iopamidol 370 injection.

Authors:  Kanako K Kumamaru; Michael L Steigner; Shigeyoshi Soga; Jason Signorelli; Arash Bedayat; Kimberly Adams; Dimitris Mitsouras; Frank J Rybicki
Journal:  AJR Am J Roentgenol       Date:  2011-10       Impact factor: 3.959

6.  Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients.

Authors:  Georg Mühlenbruch; Tobias Seyfarth; Chee Siong Soo; Namasivayam Pregalathan; Andreas Horst Mahnken
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

7.  Development of renal disease in people at high cardiovascular risk: results of the HOPE randomized study.

Authors:  Johannes F E Mann; Hertzel C Gerstein; Qi-Long Yi; Eva M Lonn; Byron J Hoogwerf; Andrew Rashkow; Salim Yusuf
Journal:  J Am Soc Nephrol       Date:  2003-03       Impact factor: 10.121

8.  Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography.

Authors:  Michael L Steigner; Hansel J Otero; Tianxi Cai; Dimitrios Mitsouras; Leelakrishna Nallamshetty; Amanda G Whitmore; Hale Ersoy; Noah A Levit; Marcelo F Di Carli; Frank J Rybicki
Journal:  Int J Cardiovasc Imaging       Date:  2008-07-29       Impact factor: 2.357

9.  Determining contrast medium dose and rate on basis of lean body weight: does this strategy improve patient-to-patient uniformity of hepatic enhancement during multi-detector row CT?

Authors:  Lisa M Ho; Rendon C Nelson; David M Delong
Journal:  Radiology       Date:  2007-05       Impact factor: 11.105

10.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

View more
  10 in total

1.  CT compared to MRI for functional evaluation of the right ventricle: a systematic review and meta-analysis.

Authors:  Hang Fu; Xuedong Wang; Kaiyue Diao; Shan Huang; Hui Liu; Yue Gao; Qin Zhao; Zhi-Gang Yang; Ying-Kun Guo
Journal:  Eur Radiol       Date:  2019-05-27       Impact factor: 5.315

2.  Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.

Authors:  Fabian Stenzel; Matthias Rief; Elke Zimmermann; Johannes Greupner; Felicitas Richter; Marc Dewey
Journal:  Eur Radiol       Date:  2014-03-26       Impact factor: 5.315

3.  Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.

Authors:  Long Jiang Zhang; Li Qi; Jing Wang; Chun Xiang Tang; Chang Sheng Zhou; Xue Man Ji; James V Spearman; Carlo Nicola De Cecco; Felix G Meinel; U Joseph Schoepf; Guang Ming Lu
Journal:  Eur Radiol       Date:  2014-04-16       Impact factor: 5.315

4.  Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography.

Authors:  Jie Liu; Jianbo Gao; Runze Wu; Yonggao Zhang; Lili Hu; Ping Hou
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-04       Impact factor: 2.357

5.  Application of 270 mgI/mL Iodinated Contrast Media in Dual-Source Computed Tomography Coronary Artery Imaging.

Authors:  Jun Zhang; Bo He; Yuan-Ling Wang; Dan Han
Journal:  Acta Cardiol Sin       Date:  2014-11       Impact factor: 2.672

6.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

7.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

8.  Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article.

Authors:  Xiaomei Zhu; Yusheng Yu; Dinghu Xu; Hong Zhang; Lijun Tang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

9.  Image quality and radiation dose of lower extremity CT angiography using 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction.

Authors:  Li Qi; Felix G Meinel; Chang Sheng Zhou; Yan E Zhao; U Joseph Schoepf; Long Jiang Zhang; Guang Ming Lu
Journal:  PLoS One       Date:  2014-06-10       Impact factor: 3.240

10.  Diagnostic performance of low-radiation-dose and low-contrast-dose (double low-dose) coronary CT angiography for coronary artery stenosis.

Authors:  Wei Zhang; Zhaogui Ba; Zhenqiang Wang; Huaying Lv; Jun Zhao; Yonghua Zhang; Feixue Zhang; Lei Song
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.