Literature DB >> 11242230

Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

K Hittmair1, D Fleischmann.   

Abstract

PURPOSE: The purpose of this work was to determine the accuracy of predicting arterial enhancement from peripheral versus central venous test bolus injections at CT angiography (CTA).
METHOD: In 40 patients with abdominal aortic aneurysms, aortoiliac enhancement profiles were predicted by mathematical deconvolution of the time-attenuation response to a 16 ml test bolus injection. Injection sites were either a cubital vein (n = 20) or a central venous injection site (n = 20). The accuracy of predicting enhancement was quantified as the "off-predicted deviation" (calculated as mean squared differences between observed minus predicted enhancement values) in all patients.
RESULTS: Off-predicted deviation was significantly smaller in the central venous injection group (17 +/- 6 HU) than the peripheral injection group (33 +/- 18 HU) (p < 0.001).
CONCLUSION: Arterial enhancement at CTA can be mathematically predicted and controlled more accurately if a central venous injection site is used. Automated saline flushing of the veins might improve the accuracy of the mathematical model for peripheral injections.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11242230     DOI: 10.1097/00004728-200103000-00024

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  14 in total

1.  Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

Authors:  Andreas H Mahnken; Ernst Klotz; Anja Hennemuth; Bettina Jung; Ralf Koos; Joachim E Wildberger; Rolf W Günther
Journal:  Eur Radiol       Date:  2003-08-06       Impact factor: 5.315

Review 2.  MDCT of the abdominal aorta: basics, technical improvements, and clinical applications.

Authors:  C Catalano; F Fraioli; M Danti; A Napoli; V Votta; K Lanciotti; L Bertoletti; R Passariello
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 5.315

Review 3.  Use of high-concentration contrast media in multiple-detector-row CT: principles and rationale.

Authors:  Dominik Fleischmann
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

4.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

5.  Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study.

Authors:  Wen Jie Yang; Ke Min Chen; Bo Liu; Li Fang Pang; Huan Zhang; Zi Lai Pan; Fu Hua Yan
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-23       Impact factor: 2.357

6.  Adaptive Bolus-chasing Computed Tomography Angiography in the Cases of Symmetric and Asymmetric Arterial Flows in Peripheral Arteries.

Authors:  Zhijun Cai; Ge Wang; Er-Wei Bai
Journal:  Biomed Signal Process Control       Date:  2009-10-01       Impact factor: 3.880

7.  Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography.

Authors:  Harald Seifarth; Michael Puesken; John F Kalafut; Susanne Wienbeck; Johannes Wessling; David Maintz; Walter Heindel; Kai-Uwe Juergens
Journal:  Eur Radiol       Date:  2009-05-08       Impact factor: 5.315

8.  An optimised patient-specific approach to administration of contrast agent for CT pulmonary angiography.

Authors:  Charbel Saade; Roger Bourne; Fadi El-Merhi; Arjuna Somanathan; Dev Chakraborty; Patrick Brennan
Journal:  Eur Radiol       Date:  2013-06-04       Impact factor: 5.315

Review 9.  Multislice CT: technical principles and future trends.

Authors:  Mathias Prokop
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

10.  64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial.

Authors:  Christian Loewe; Christoph R Becker; Riccardo Berletti; Carlo Alberto Cametti; Jerome Caudron; Walter Coudyzer; Johan De Mey; Massimo Favat; Jean-François Heautot; Sam Heye; Markus Hittinger; Antoine Larralde; Jean-Pierre Lestrat; Roberto Marangoni; Koenraad Nieboer; Peter Reimer; Martin Schwarz; Melanie Schernthaner; Johannes Lammer
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.