Literature DB >> 21940571

Coronary enhancement for prospective ECG-gated single R-R axial 320-MDCT angiography: comparison of 60- and 80-mL iopamidol 370 injection.

Kanako K Kumamaru1, Michael L Steigner, Shigeyoshi Soga, Jason Signorelli, Arash Bedayat, Kimberly Adams, Dimitris Mitsouras, Frank J Rybicki.   

Abstract

OBJECTIVE: The objective of our study was to evaluate the difference in coronary enhancement provided by 60 versus 80 mL of contrast medium (370 mg I/mL) for prospectively ECG-gated single-heartbeat axial 320-MDCT.
MATERIALS AND METHODS: We retrospectively evaluated 108 consecutive 320-MDCT angiography studies. Group 1 (n = 36) received 60 mL of an iodinated contrast medium and group 2 (n = 72), 80 mL. All patients were imaged with a standardized protocol: iopamidol 370 followed by 40 mL of saline, both administered at a rate of 6 mL/s. Two imagers subjectively assessed image quality throughout the coronary arteries. Region-of-interest attenuation (HU) measurements were performed in the aorta plus the proximal and distal coronary arteries.
RESULTS: Subjective analysis of all coronary segments showed slightly better image quality for group 2. Patients in group 1 had significantly (p < 0.05) lower mean attenuation values for the individual coronary vessels. Nevertheless, 96.7% of all coronary segments in the group 1 patients had an attenuation of greater than 300 HU; when analysis was limited to group 1 patients with a body mass index of greater than 30, 92.8% of the segments were more than 300 HU, and all segments measured more than 250 HU.
CONCLUSION: An injection protocol based on 60 mL of iopamidol (370 mg I/mL) for prospectively ECG-gated wide-area detector single-heartbeat coronary CT angiography (CTA) has less coronary enhancement than a protocol based on 80 mL. However, using 60 mL, more than 96% of coronary segments had sufficient enhancement (i.e., > 300 HU), supporting the general use of 60-mL protocols for clinical wide-area detector coronary CTA.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21940571     DOI: 10.2214/AJR.10.5980

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

1.  Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

2.  Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.

Authors:  Rihyeon Kim; Eun-Ah Park; Whal Lee; Jin Wook Chung
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

Review 3.  Important advances in technology and unique applications to cardiovascular computed tomography.

Authors:  Kongkiat Chaikriangkrai; Su Yeon Choi; Faisal Nabi; Su Min Chang
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

4.  A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.

Authors:  Dominik C Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A Fuchs; Julia Stehli; Olivier F Clerc; Mathias Possner; Aju P Pazhenkottil; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

5.  Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality.

Authors:  Sei Komatsu; Teruaki Kamata; Atsuko Imai; Tomoki Ohara; Mitsuhiko Takewa; Ryoko Ohe; Kazuaki Miyaji; Junichi Yoshida; Kazuhisa Kodama
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-26       Impact factor: 2.357

6.  Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study.

Authors:  Wen Jie Yang; Ke Min Chen; Bo Liu; Li Fang Pang; Huan Zhang; Zi Lai Pan; Fu Hua Yan
Journal:  Int J Cardiovasc Imaging       Date:  2012-05-23       Impact factor: 2.357

7.  Optimizing contrast medium injection protocol individually with body weight for high-pitch prospective ECG-triggering coronary CT angiography.

Authors:  Jie Liu; Jianbo Gao; Runze Wu; Yonggao Zhang; Lili Hu; Ping Hou
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-04       Impact factor: 2.357

8.  High-pitch dual-source CT coronary angiography with low volumes of contrast medium.

Authors:  Alexander Lembcke; Carsten Schwenke; Patrick A Hein; Gesine Knobloch; Tahir Durmus; Bernd Hamm; Alexander Huppertz
Journal:  Eur Radiol       Date:  2013-08-15       Impact factor: 5.315

9.  Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Authors:  Sock Keow Tan; Kwan Hoong Ng; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Fadhli Mohamed Sani; Yang Faridah Abdul Aziz; Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2019-04

10.  Cine computed tomography angiography evaluation of blood flow for full face transplant surgical planning.

Authors:  Geoffroy C Sisk; Kanako K Kumamaru; Kurt Schultz; Ericka M Bueno; J Rodrigo Diaz-Siso; Elizabeth George; Marta M Redjaee; Dimitrios Mitsouras; Michael L Steigner; Bohdan Pomahac; Frank J Rybicki
Journal:  Eplasty       Date:  2012-12-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.