Personalized administration of contrast medium with high delivery rate in low tube voltage coronary computed tomography angiography.

Sock Keow Tan1,2, Kwan Hoong Ng1,2, Chai Hong Yeong3, Raja Rizal Azman Raja Aman1,2, Fadhli Mohamed Sani1,2, Yang Faridah Abdul Aziz1,2, Zhonghua Sun4.   

Abstract

BACKGROUND: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol.
METHODS: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.
RESULTS: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).
CONCLUSIONS: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

Entities:  

Keywords:  Coronary computed tomography angiography (CCTA); contrast medium; image quality; radiation dose; total iodine dose (TID)

Year:  2019        PMID: 31143647      PMCID: PMC6511728          DOI: 10.21037/qims.2019.03.13

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  51 in total

1.  Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.

Authors:  Hiromasa Suzuki; Hidekazu Oshima; Norio Shiraki; Chisa Ikeya; Yuta Shibamoto
Journal:  Eur Radiol       Date:  2004-08-12       Impact factor: 5.315

2.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

Authors:  Filippo Cademartiri; Erica Maffei; Anselmo Alessandro Palumbo; Roberto Malagò; Ludovico La Grutta; W Bob Meiijboom; Annachiara Aldrovandi; Michele Fusaro; Luigi Vignali; Alberto Menozzi; Valerio Brambilla; Paolo Coruzzi; Massimo Midiri; Miles A Kirchin; Nico R A Mollet; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2007-10-13       Impact factor: 5.315

5.  Soft and intermediate plaques in coronary arteries: how accurately can we measure CT attenuation using 64-MDCT?

Authors:  Jun Horiguchi; Chikako Fujioka; Masao Kiguchi; Yun Shen; Christian E Althoff; Hideya Yamamoto; Katsuhide Ito
Journal:  AJR Am J Roentgenol       Date:  2007-10       Impact factor: 3.959

6.  Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering.

Authors:  Bernhard A Herzog; Lars Husmann; Ines Valenta; Fabian M Tay; Nina Burkhard; Oliver Gaemperli; Christophe A Wyss; Ulf Landmesser; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2009-04-19       Impact factor: 2.357

7.  64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis.

Authors:  Xiaolu Fei; Xiangying Du; Qi Yang; Yun Shen; Pengyu Li; Jingmin Liao; Kuncheng Li
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

8.  Body surface area prediction in normal-weight and obese patients.

Authors:  E H Livingston; S Lee
Journal:  Am J Physiol Endocrinol Metab       Date:  2001-09       Impact factor: 4.310

9.  Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity.

Authors:  Kyongtae T Bae; Brian A Seeck; Charles F Hildebolt; Cheng Tao; Fang Zhu; Masayuki Kanematsu; Pamela K Woodard
Journal:  AJR Am J Roentgenol       Date:  2008-03       Impact factor: 3.959

10.  Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters.

Authors:  Hatem Alkadhi; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Stephan Baumüller; André Plass; Michele Genoni; Borut Marincek; Sebastian Leschka
Journal:  Eur J Radiol       Date:  2008-10-30       Impact factor: 3.528

View more
  7 in total

1.  Acute type A aortic intramural hematoma and type A aortic dissection: correlation between the intimal tear features and pathogenesis.

Authors:  Yu Li; Nan Zhang; Shangdong Xu; Zhanming Fan; Junming Zhu; Lianjun Huang; Dong Chen; Zhonghua Sun; Lizhong Sun
Journal:  Quant Imaging Med Surg       Date:  2020-07

2.  Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study.

Authors:  Jihang Sun; Haoyan Li; Jianying Li; Yongli Cao; Zuofu Zhou; Michelle Li; Yun Peng
Journal:  Quant Imaging Med Surg       Date:  2021-09

3.  Machine learning-based prediction of insufficient contrast enhancement in coronary computed tomography angiography.

Authors:  H A Marquering; R N Planken; R R Lopes; T P W van den Boogert; N H J Lobe; T A Verwest; J P S Henriques
Journal:  Eur Radiol       Date:  2022-06-16       Impact factor: 7.034

4.  Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography: feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2.

Authors:  Liang Jin; Bing Jie; Yiyi Gao; An'qi Jiang; Tingwen Weng; Ming Li
Journal:  Quant Imaging Med Surg       Date:  2021-06

5.  Impact of iodine concentration and scan parameters on image quality, contrast enhancement and radiation dose in thoracic CT.

Authors:  Marian S Solbak; Mette K Henning; Andrew England; Anne C Martinsen; Trond M Aaløkken; Safora Johansen
Journal:  Eur Radiol Exp       Date:  2020-09-11

6.  Contrast medium administration with a body surface area protocol in step-and-shoot coronary computed tomography angiography with dual-source scanners.

Authors:  Liang Jin; Yiyi Gao; Yingli Sun; Cheng Li; Pan Gao; Wei Zhao; Ming Li
Journal:  Sci Rep       Date:  2020-10-07       Impact factor: 4.379

7.  Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model.

Authors:  Niclas Schmitt; Ralf O Floca; Daniel Paech; Rami A El Shafie; Ulf Neuberger; Martin Bendszus; Markus A Möhlenbruch; Dominik F Vollherbst
Journal:  Clin Neuroradiol       Date:  2021-04-14       Impact factor: 3.649

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.