OBJECTIVES: Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. METHODS: We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). RESULTS: Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). CONCLUSIONS: Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. KEY POINTS: Fixed threshold bolus tracking is suitable for coronary 320-row CT angiography. Manual fast start bolus tracking can reduce contrast agent volumes. Manual fast start and fixed threshold initiation achieve good image quality. Fixed threshold bolus tracking achieves a more reliable contrast bolus position.
OBJECTIVES: Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. METHODS: We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). RESULTS: Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). CONCLUSIONS: Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. KEY POINTS: Fixed threshold bolus tracking is suitable for coronary 320-row CT angiography. Manual fast start bolus tracking can reduce contrast agent volumes. Manual fast start and fixed threshold initiation achieve good image quality. Fixed threshold bolus tracking achieves a more reliable contrast bolus position.
Authors: Christoph R Becker; Cheng Hong; Andreas Knez; Alexander Leber; Roland Bruening; U Joseph Schoepf; Maximilian F Reiser Journal: Invest Radiol Date: 2003-11 Impact factor: 6.016
Authors: Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker Journal: Eur Radiol Date: 2006-05-13 Impact factor: 5.315
Authors: Francesca Pugliese; Nico R A Mollet; Giuseppe Runza; Carlos van Mieghem; Willem B Meijboom; Patrizia Malagutti; Timo Baks; Gabriel P Krestin; Pim J deFeyter; Filippo Cademartiri Journal: Eur Radiol Date: 2005-11-16 Impact factor: 5.315
Authors: Bon-Kwon Koo; Andrejs Erglis; Joon-Hyung Doh; David V Daniels; Sanda Jegere; Hyo-Soo Kim; Allison Dunning; Tony DeFrance; Alexandra Lansky; Jonathan Leipsic; James K Min Journal: J Am Coll Cardiol Date: 2011-11-01 Impact factor: 24.094
Authors: Filippo Cademartiri; Nico R Mollet; Pedro A Lemos; Fransesco Saia; Massimo Midiri; Pim J de Feyter; Gabriel P Krestin Journal: AJR Am J Roentgenol Date: 2006-10 Impact factor: 3.959
Authors: S Feger; A Shaban; S Lukas; C Kendziorra; M Rief; E Zimmermann; M Dewey Journal: Int J Cardiovasc Imaging Date: 2016-11-10 Impact factor: 2.357