Literature DB >> 22249862

Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin.

Douglas A Colquhoun1, Katherine T Forkin, Marcel E Durieux, Robert H Thiele.   

Abstract

The decision to administer blood products is complex and multifactorial. Accurate assessment of the concentration of hemoglobin [Hgb] is a key component of this evaluation. Recently a noninvasive method of continuously measuring hemoglobin (SpHb) has become available with multi-wavelength Pulse CO-Oximetry. The accuracy of this device is well documented, but the trending ability of this monitor has not been previously described. Twenty patients undergoing major thoracic and lumbar spine surgery were recruited. All patients received radial arterial lines. On the contralateral index finger, a R1 25 sensor (Rev E) was applied and connected to a Radical-7 Pulse CO-Oximeter (both Masimo Corp, Irvine, CA). Blood samples were drawn intermittently at the anesthesia provider's discretion and were analyzed by the operating room satellite laboratory CO-Oximeter. The value of Hgb and SpHb at that time point was compared. Trend analysis was performed by the four quadrant plot technique, testing directionality of change, and Critchley's polar plot method testing both directionality and magnitude of the change in values. Eighty-eight samples recorded at times of sufficient signal quality were available for analysis. Four quadrant plot analysis revealed 94% of data within the quadrants associated with the correct direction change, and 90% of data points lay within the analysis bounds proposed by Critchley. Pulse CO-Oximetry offers an acceptable trend monitor in patients undergoing major spine surgery. Future work should explore the ability of this device to detect large changes in hemoglobin, as well as its applicability in additional surgical and non-surgical patient populations.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22249862     DOI: 10.1007/s10877-012-9335-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  18 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

Review 2.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

3.  Non-invasive monitoring of blood haemoglobin for analysis of fluid volume kinetics.

Authors:  R G Hahn; Y Li; J Zdolsek
Journal:  Acta Anaesthesiol Scand       Date:  2010-11       Impact factor: 2.105

4.  Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution.

Authors:  A C Perrino; S N Harris; M A Luther
Journal:  Anesthesiology       Date:  1998-08       Impact factor: 7.892

5.  Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach.

Authors:  Maxime Cannesson; Yannick Le Manach; Christoph K Hofer; Jean Pierre Goarin; Jean-Jacques Lehot; Benoît Vallet; Benoît Tavernier
Journal:  Anesthesiology       Date:  2011-08       Impact factor: 7.892

6.  Assessment of trending ability of cardiac output monitors by polar plot methodology.

Authors:  Lester A Critchley; Xiao X Yang; Anna Lee
Journal:  J Cardiothorac Vasc Anesth       Date:  2011-03-17       Impact factor: 2.628

7.  The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery.

Authors:  Ba-Vinh Nguyen; Jean-Louis Vincent; Emmanuel Nowak; Michelle Coat; Nicolas Paleiron; Pierre Gouny; Mehdi Ould-Ahmed; Maité Guillouet; Charles Christian Arvieux; Gildas Gueret
Journal:  Anesth Analg       Date:  2011-09-14       Impact factor: 5.108

8.  Performance evaluation of a noninvasive hemoglobin monitoring device.

Authors:  Etienne Gayat; Antoine Bodin; Caroline Sportiello; Mireille Boisson; Jean-François Dreyfus; Emmanuel Mathieu; Marc Fischler
Journal:  Ann Emerg Med       Date:  2011-01-19       Impact factor: 5.721

9.  Continuous noninvasive hemoglobin monitoring during complex spine surgery.

Authors:  Lauren Berkow; Stephanie Rotolo; Erin Mirski
Journal:  Anesth Analg       Date:  2011-09-29       Impact factor: 5.108

10.  Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station.

Authors:  Marlin Wayne Causey; Seth Miller; Andrew Foster; Alec Beekley; David Zenger; Matthew Martin
Journal:  Am J Surg       Date:  2011-05       Impact factor: 2.565

View more
  11 in total

1.  Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis.

Authors:  Hosein Shabaninejad; Nashmil Ghadimi; Kourosh Sayehmiri; Hossein Hosseinifard; Rasoul Azarfarin; Hasan Abolghasem Gorji
Journal:  J Anesth       Date:  2019-03-20       Impact factor: 2.078

2.  The relative trending accuracy of noninvasive continuous hemoglobin monitoring during hemodialysis in critically ill patients.

Authors:  Hiroshi Yamada; Minako Saeki; Junko Ito; Kazuhiro Kawada; Aya Higurashi; Hiromi Funakoshi; Kohji Takeda
Journal:  J Clin Monit Comput       Date:  2014-05-03       Impact factor: 2.502

3.  Noninvasively Measured Hemoglobin Concentration Reflects Arterial Hemoglobin Concentration Before but Not After Cardiopulmonary Bypass in Patients Undergoing Coronary Artery or Valve Surgery.

Authors:  Matthias L Riess; Paul S Pagel
Journal:  J Cardiothorac Vasc Anesth       Date:  2016-03-24       Impact factor: 2.628

4.  Accuracy of non-invasive continuous total hemoglobin measurement by Pulse CO-Oximetry in severe traumatized and surgical bleeding patients.

Authors:  Werner Baulig; Burkhardt Seifert; Donat R Spahn; Oliver M Theusinger
Journal:  J Clin Monit Comput       Date:  2015-12-19       Impact factor: 2.502

Review 5.  How Noninvasive Haemoglobin Measurement with Pulse CO-Oximetry Can Change Your Practice: An Expert Review.

Authors:  Gregor Lindner; Aristomenis K Exadaktylos
Journal:  Emerg Med Int       Date:  2013-08-22       Impact factor: 1.112

6.  Meta-analytic estimation of measurement variability and assessment of its impact on decision-making: the case of perioperative haemoglobin concentration monitoring.

Authors:  Emmanuel Charpentier; Vincent Looten; Björn Fahlgren; Alexandre Barna; Loïc Guillevin
Journal:  BMC Med Res Methodol       Date:  2016-01-19       Impact factor: 4.615

7.  Optimal Signal Quality Index for Photoplethysmogram Signals.

Authors:  Mohamed Elgendi
Journal:  Bioengineering (Basel)       Date:  2016-09-22

8.  Validity of accuracy and trending ability of non-invasive continuous total hemoglobin measurement in complex spine surgery: a prospective cohort study.

Authors:  Feng-Cheng Chang; Jr-Rung Lin; Fu-Chao Liu
Journal:  BMC Anesthesiol       Date:  2019-07-04       Impact factor: 2.217

9.  Optical Fibre-Based Pulse Oximetry Sensor with Contact Force Detection.

Authors:  Chong Liu; Ricardo Correia; Hattan Khaled Ballaji; Serhiy Korposh; Barrie R Hayes-Gill; Stephen P Morgan
Journal:  Sensors (Basel)       Date:  2018-10-26       Impact factor: 3.576

10.  Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children-a method comparison study.

Authors:  Aditya Bhat; Amit Upadhyay; Vijay Jaiswal; Deepak Chawla; Dharamveer Singh; Mithilesh Kumar; C P Yadav
Journal:  Eur J Pediatr       Date:  2015-08-19       Impact factor: 3.183

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.